2500kVA FR3 Vegetable Oil Transformers for Australian Mining Site
Project Overview
This project delivered a custom transformer package for an active mining operation in Australia, where strict environmental protection rules and rugged site operating conditions set high technical barriers for power distribution equipment.
The client required five distribution transformers plus one earthing transformer, with the main unit rated at OPMI 2500kVA, 11kV / 415V. Instead of conventional mineral oil, the client selected FR3 high-fire-point vegetable dielectric fluid to meet Australia’s stringent environmental & fire safety requirements.
Core Project Requirements
Dielectric Fluid: FR3 high flash-point vegetable oil. Biodegradable, low toxicity, greatly reduces fire hazard and soil contamination risk — critical for Australian mine environmental compliance.
Transformer Configuration: 5 × distribution transformers + 1 × earthing transformer. Main transformer: OPMI 2500kVA, 11kV / 415V, mining & industrial duty.
Mechanical Design: Reinforced cooling system as required by Australian standards, to handle high ambient temperature and continuous heavy-load mining operation.
Containment & Safety: Integral oil containment sump (oil pit / bund) to contain fluid leakage, preventing soil and groundwater pollution, mandatory for Australian mine sites.
Earthing transformer: Dedicated earthing transformer included for proper neutral earthing, stabilising 11kV network fault conditions on the mine power system.
Our Customised Solution
We engineered the full transformer package tailored to Australian mining specifications:
- Main OPMI 2500kVA 11kV/415V distribution transformers filled with FR3 vegetable oil. FR3’s biodegradable properties satisfy Australia’s strict environmental controls, while its high fire point minimises fire risk in remote mine sites.
- Cooling structure reinforced to meet Australian thermal requirements, ensuring stable heat dissipation under continuous heavy mining cyclic loads and high ambient temperatures.
- Complete oil containment bund / oil pit design integrated into the layout. Any accidental oil leakage will be fully contained, protecting the local land and water environment.
- Separate dedicated earthing transformer supplied alongside the five distribution transformers. It stabilises the 11kV power network, manages earth faults and improves mine grid safety.
- All units undergo full factory acceptance testing before shipment, with complete documentation for site inspection and Australian project approval.




Project Benefits & Outcomes
✅ Environmental Compliance: FR3 vegetable oil is biodegradable, meeting Australia’s strict mine environmental protection regulations. Low spill contamination risk.
✅ Enhanced Fire Safety: High fire-point FR3 fluid drastically lowers fire risk for remote mining infrastructure.
✅ Rugged Thermal Performance: Reinforced cooling system guarantees reliable operation under Australia’s harsh hot ambient mine conditions.
✅ Complete Grid Protection: The dedicated earthing transformer delivers secure neutral grounding and fault protection for the mine’s 11kV distribution network.
✅ Leak Containment: Oil bund / oil pit prevents soil and groundwater contamination in case of fluid leakage.
This turnkey transformer package combining FR3 vegetable oil transformers + earthing transformer and oil containment system offers a robust, eco-friendly power distribution solution for Australian mining and heavy industrial sites. It fully addresses local environmental, fire safety and thermal design requirements for 11kV mining power networks.
Empower Your Grid with Tengyi’s Specialized Global Expertise
Tengyi delivers the technical certainty your critical grid projects demand across the globe. From our 33kV Utility-Grade Solutions , optimized for African power grids, to our Americas Exclusive Series (IEEE/ANSI Standards), our expert team provides the technical precision and secure logistics needed to ensure stable, long-term operation in even the most challenging environments.
