About Us

Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services.

CORPORATE STRENGTH

About Tengyi

Tengyi is a leading manufacturer of high-quality electrical transformers, renowned for the commitment to innovation, efficiency, and reliability.

We cover voltage levels from 10kV to 110kV mass production and 500kV R&D capability. Tengyi is a trusted OEM partner to Fortune 500 companies and international energy leaders across 69+ countries.

Operating across 353,335 m² of total land area with nearly 200,000 m² of modern intelligent manufacturing workshops across three factory sites in Tongshan High-tech Zone, Tengyi combines massive industrial scale with advanced engineering. Powered by over 1,500 employees—including 200+ specialized R&D and technical staff—we achieve an annual production capacity exceeding 20,000 units.

High efficiency, low loss, and exceptional stability

Global standard compliance for long-lasting durability

Full customization tailored to your exact needs

0
Dedicated Workforce
0
Professional R&D Staff
0
Annual Units Capacity
0
Global Export Countries

Powering Global Grids with Precision Engineering

Core Offerings and Engineering Capabilities

Core Product Portfolio:

Distribution Transformers

Specs: Capacity range from 5 kVA to 15,000 kVA for local and utility power grids.

Types: Single and three-phase pole-mounted, pad-mounted, and substation models.

Usage: Engineered for residential, commercial, urban, and rural distributions.

Power Transformers

Specs: Capacity from 50 MVA to 240 MVA covering high-voltage grid levels 35kV-500kV.

Types: High-efficiency, low-loss power designs engineered for heavy utility loads.

Usage: Applied in utility substations, regional power grids, and industrial plants.

Renewable & Energy Storage

Specs: Turnkey renewable station storage and step-up transformer substations.

Types: Integrated assembly solutions for solar, wind, and battery BESS cabinets.

Usage: Deployed in photovoltaic farms, wind power stations, and utility BESS units.

Core Competencies:

Custom Voltage Expertise

Custom distribution and high-voltage transformers engineered for power grids.

Turnkey BESS Integration

Seamlessly integrated assembly solutions for new energy storage cabinet units.

Fortune 500 OEM Partner

Trusted OEM partner to Fortune 500 companies and international energy leaders.

Global Export Footprint

Serving utility and industrial clients in 69+ countries across 5 continents.

Mission: Empowering global energy transition with high-efficiency transformers and integrated storage solutions.

Vision: To be the most trusted global power equipment partner for a sustainable energy future.

Values: Certified National Green Factory committed to full-lifecycle equipment safety and eco-friendly manufacturing.

Integrity: Guided by public company governance standards for lasting global trust.

Innovation: Pushing technological boundaries from 10kV to 500kV, advancing smart grid and energy storage solutions.

Customer Focus: Delivering tailored, one-stop engineering solutions under Fortune 500 OEM partner standards.

Long Lasting Warranty

We offer a standard warranty of 12 months from commissioning or 24 months from B/L date (whichever comes first), covering manufacturing defects in materials and workmanship with free replacement of defective parts.

Clients receive 24/7 English and Spanish technical support with remote diagnosis and video guidance within 2 hours. In-stock spare parts are dispatched via 5–7 days of air freight or 3–4 weeks of sea freight, with global on-site service available at transparent costs.

Our Strength

We provide end-to-end services, including design, installation, maintenance, and support, ensuring seamless integration and operation of your power systems. Our commitment to quality and innovation guarantees that you receive the best possible solutions to enhance your operational efficiency and energy management.

Low Noise Eco Design

We engineer our low-noise transformers to minimize energy losses and protect the environment. By fully complying with EU Ecodesign standards, we help you lower operational costs while ensuring reliable grid efficiency. You can trust our eco-friendly designs to power your projects sustainably.

Short Circuit Withstand

Built with proven manufacturing technology, Tengyi’s transformers easily withstand extreme short-circuit stress. Through rigorous testing and precision design, we keep your equipment safe under harsh electrical conditions. Your power grid gains complete stability and uninterrupted uptime.

Hybrid Insulation System

By pioneering synthetic and natural ester liquids, we combine high-thermal insulation with advanced safety. This hybrid design gives you compact transformers with higher power capacity and reduced environmental risks. You achieve peak performance even in space-constrained project sites.

High Voltage Manufacturing

Across 353,000 m² of modern facilities with a 500kV testing station, our manufacturing scale meets your largest grid demands. From 10kV–110kV mass output to 500kV R&D, we guarantee massive production capacity. You receive zero-defect quality backed by on-time worldwide delivery.

Renewable Energy Storage

Tailored specifically for solar, wind, and battery storage, our turnkey assembly solutions streamline your clean energy projects. Integrating storage cabinets and substations, we simplify your procurement process. Your renewable assets run more efficiently right from day one.

Tailored Global Solutions

Custom transformer engineering is at the heart of what we do for your unique grid and project specifications. Whether you operate solar, wind, hydro, or biomass facilities, we adapt every detail to your budget. You gain proven reliability backed by years of global experience.

History of Our Tengyi

A strategic subsidiary of a listed Chinese power group, exclusively focused on delivering high-end energy solutions to the global market.

2007

Founded in Xuzhou; accredited as a National High-Tech Enterprise.

Established TENGYI International Division for worldwide exports.

2017

2022

SSE Listed (Code: 603097); awarded National “Little Giant”.

Expanded into PV transformers and energy storage (BESS).

2024

2026

Doubled overseas sales, exporting to 69+ countries.

2007

Founded in Xuzhou; accredited as a National High-Tech Enterprise.

2017

Established TENGYI International Division for worldwide exports.

2022

SSE Listed (Code: 603097); awarded National “Little Giant”.

2024

Expanded into PV transformers and energy storage (BESS).

2026

Doubled overseas sales, exporting to 69+ countries.

Manufacturing Process

From CRGO raw materials to 500kV laboratory testing, our 8-step precision process guarantees uncompromised equipment reliability.

Iron Core Processing

Precision Core Fabrication

Cutting, packing, and binding Cold-Rolled Grain-Oriented (CRGO) silicon steel sheets for minimum core loss.

Coil Winding Systems

Advanced Coil Winding

Segmental winding technology using high-purity oxygen-free copper flat wire for optimal conductivity.

Insulation Treatment

Advanced vacuum drying, impregnation, and high-temperature curing to eliminate moisture and air bubbles.

Body Assembly

Precise core and coil assembly followed by strict dielectric insulation tests in clean workshops.

Fuel Tank & Accessories

Robust fuel tank welding and radiator cooling system installation to withstand harsh weather conditions.

Vacuum Filling

High-vacuum injection of 25# or 45# premium transformer oil ensuring maximum dielectric strength.

500kV Factory Test

Comprehensive routine and type testing conducted in our 500kV testing station to guarantee zero defects.

Global Packing & Shipping

Supporting client Factory Acceptance Testing (FAT) and heavy-duty moisture-proof global packaging.

Global Cases

Covering 110kV high-voltage substations, SGS-certified national grid tenders, and heavy industrial facilities across 69+ countries, TENGYI’s global references demonstrate proven equipment reliability under extreme operating conditions. By combining third-party inspected quality with Fortune 500 OEM partnership standards, we deliver bankable, low-risk power solutions tailored for international utilities and industrial leaders.

Uzbekistan
110kV 16/20MVA Power Transformers (2 Sets)
Regional Utility Substation

Rwanda
11kV Distribution Transformers (110+ Units)
National Grid & SGS Certified

Chile
3-Phase Pad-Mounted Transformers (10 Units)
Local Power Grid Upgrade

Guatemala
Industrial Power Transformers
AG Sidegua Steel Plant

Global Sales and Market Presence

Driven by strong manufacturing capacity and international trust, Tengyi achieved $65 million in total revenue with $50 million in global export sales.

$65M

Total Annual Revenue

$50M

Global Export Revenue

69+

Export Countries

North America

38% ($25M)

Key Countries: USA, Canada, and Mexico

Leading export region with strong utility and industrial pad-mounted transformer demand.

Central Asia

25% ($16.7M)

Key Countries: Uzbekistan, Kazakhstan, and Kyrgyzstan

Key regional market for high-voltage substations and power grid expansion.

Latin America

16% ($10.7M)

Key Countries: Brazil, Argentina, Colombia, Ecuador, Venezuela, and Peru

A rapidly expanding region driven by renewable energy and grid modernization.

Southeast Asia

9% ($6M)

Key Countries: Vietnam, Malaysia, Singapore, Thailand, Indonesia, and the Philippines

Strategic network serving urban grid infrastructure and industrial developments.

Middle East

5% ($3.5M)

Key Countries: Iran, Iraq, Turkey, Syria, and Jordan

Regional market supporting heavy industrial power and grid projects.

Other Markets

6% ($4.5M)

Key Countries: Laos, Cambodia, Australia, Rwanda, Nigeria, and Saudi Arabia

Expanding global footprint serving emerging utility and industrial needs.

Our Transformer Specialists

The foundation of Tengyi lies in our dedicated and skilled team of engineers, designers, and industry experts, who are committed to delivering high-quality, reliable transformer solutions for clients worldwide. With deep technical knowledge, years of hands-on experience, and a passion for innovation, our team works closely with you to understand your unique power needs, operational challenges, and budget requirements. Simply share your project goals and expectations, and our professionals will leverage their expertise to design and deliver customized transformer solutions that ensure efficiency, safety, and performance.

Abigail Zhang

– Product Consulation Manager

Skilled at different comprehensive power transformer solution provide, precisely solve problems related to power equipment in substations.

Daisy

– Product Sales Manager

Expertise in various types of transformers, focus on patiently listening to your challenges and goals, providing clear explanations, and finding the right fit.

A Letter to Our Valued Customer

Tengyi, located in China, proudly boasts that our equipment is utilized in nearly every country around the globe. As industry experts, we provide high-quality products and innovative solutions to meet our customers’ needs. We also design transformers that meet different grid demands and evolving regulations.

With its high-performance and reliable technology, we provide equipment to 88 countries around the world, including transformer equipment for solar power plants and industrial enterprises in the US and EU markets, meeting the most cutting-edge technical needs of customers.

We look forward to becoming internationally recognized transformer manufacturers, as well as we also provide customized transformer service for our peers. Our goal is to effectively serve our end customers, enhance transformer production capacity, address global energy efficiency challenges, and deliver high-quality solutions to clients worldwide.

We make a solemn commitment: all Tengyi transformers undergo rigorous testing prior to shipment and must meet stringent quality standards while complying with the electrical standards of the customer’s country. We provide all relevant international certifications, including CE, UL, and others.

Tengyi is fully prepared to support our customers and contribute to your success.

Best Regards,

The TENGYI Team, China

Strategic Cooperation

We offer the best solutions for your actual requirements.

Talk to our experts to get your tailor-made solutions.