{"id":1811,"date":"2025-12-19T14:11:49","date_gmt":"2025-12-19T06:11:49","guid":{"rendered":"https:\/\/tengyielectric.com\/?p=1811"},"modified":"2025-12-22T16:48:13","modified_gmt":"2025-12-22T08:48:13","slug":"%d0%bf%d0%be%d1%81%d1%82%d0%b0%d0%b2%d0%ba%d0%b0-%d0%be%d0%b4%d0%bd%d0%be%d1%84%d0%b0%d0%b7%d0%bd%d1%8b%d1%85-%d1%82%d1%80%d0%b0%d0%bd%d1%81%d1%84%d0%be%d1%80%d0%bc%d0%b0%d1%82%d0%be%d1%80%d0%be%d0%b2","status":"publish","type":"post","link":"https:\/\/tengyielectric.com\/ru\/single-phase-transformers-delivery-to-the-philippines\/","title":{"rendered":"\u041f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b"},"content":{"rendered":"<div class=\"gb-container gb-container-3e46977c\">\n<div class=\"gb-container gb-container-07fbd4be\">\n<div class=\"gb-container gb-container-dbe22cd8\">\n\n<h2 class=\"gb-headline gb-headline-15dcb0ac gb-headline-text\"><strong><strong><strong><strong>\u0414\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0432 \u043f\u043e\u043b\u043d\u043e\u043c 40-\u0444\u0443\u0442\u043e\u0432\u043e\u043c \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0435 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b<\/strong><\/strong><\/strong><\/strong><\/h2>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9ba03615\">\n<div class=\"gb-container gb-container-d8e45bca\">\n<div class=\"gb-container gb-container-06e5aada\">\n\n<p class=\"wp-block-paragraph\">\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043c\u044b \u0443\u0441\u043f\u0435\u0448\u043d\u043e \u0437\u0430\u0433\u0440\u0443\u0437\u0438\u043b\u0438 \u0438 \u043e\u0442\u043f\u0440\u0430\u0432\u0438\u043b\u0438&nbsp;<strong>\u043f\u043e\u043b\u043d\u044b\u0439 40-\u0444\u0443\u0442\u043e\u0432\u044b\u0439 \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440 \u0441 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u043c\u0438 \u043e\u043f\u043e\u0440\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438<\/strong> \u0432 \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0438 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u041e\u0431\u0437\u043e\u0440 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041a\u043e\u0433\u0434\u0430 \u0432\u0435\u0434\u0443\u0449\u0438\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u0430\u0445 \u2014 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u0441 \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c 30-\u043b\u0435\u0442\u043d\u0438\u043c \u043e\u043f\u044b\u0442\u043e\u043c \u043e\u043f\u0442\u043e\u0432\u043e\u0439 \u0438 \u0440\u043e\u0437\u043d\u0438\u0447\u043d\u043e\u0439 \u0442\u043e\u0440\u0433\u043e\u0432\u043b\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u2014 \u0441\u0442\u043e\u043b\u043a\u043d\u0443\u043b\u0441\u044f \u0441 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u043f\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0437\u0430\u043f\u0430\u0441\u044b \u0434\u043b\u044f \u0443\u0434\u043e\u0432\u043b\u0435\u0442\u0432\u043e\u0440\u0435\u043d\u0438\u044f \u0441\u0440\u043e\u0447\u043d\u044b\u0445 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0435\u0439 \u043c\u0435\u0441\u0442\u043d\u043e\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438, \u043e\u043d \u043e\u0431\u0440\u0430\u0442\u0438\u043b\u0441\u044f \u043a \u0441\u0432\u043e\u0435\u043c\u0443 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u043c\u0443 \u043f\u0430\u0440\u0442\u043d\u0451\u0440\u0443: \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 Tengyi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u041e\u043f\u0438\u0440\u0430\u044f\u0441\u044c \u043d\u0430 \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0433\u043e \u0441\u043e\u0442\u0440\u0443\u0434\u043d\u0438\u0447\u0435\u0441\u0442\u0432\u0430, \u043a\u043b\u0438\u0435\u043d\u0442 \u0437\u0430\u043f\u0440\u043e\u0441\u0438\u043b \u043f\u043e\u043b\u043d\u0443\u044e \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0430 (FCL) \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u043e \u0441\u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u043c\u0438 \u043e\u043f\u043e\u0440\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0441 \u0442\u043e\u0447\u043d\u043e\u0439 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u043e\u0439 \u0438 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435\u043c \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u0445 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432.<\/p>\n\n\n<div class=\"gb-container gb-container-4a6116f7\">\n<div class=\"gb-container gb-container-2569392e\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-0967f1e1\">\n<div class=\"gb-grid-column gb-grid-column-fed1e284\"><div class=\"gb-container gb-container-fed1e284\">\n\n<figure class=\"gb-block-image gb-block-image-51d6c419\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-51d6c419\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3.webp\" alt=\"\" title=\"38 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-27b58bf8\"><div class=\"gb-container gb-container-27b58bf8\">\n\n<figure class=\"gb-block-image gb-block-image-cac36d86\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-cac36d86\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1.webp\" alt=\"\" title=\"38 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f2c1613a\"><div class=\"gb-container gb-container-f2c1613a\">\n\n<figure class=\"gb-block-image gb-block-image-c4785edf\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-c4785edf\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2.webp\" alt=\"\" title=\"38 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0442 Tengyi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Tengyi \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043b\u0430 \u0441\u0432\u043e\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0439 \u043e\u043f\u044b\u0442 \u0434\u043b\u044f \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u043e\u0433\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u044f, \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0433\u043e \u0442\u043e\u0447\u043d\u044b\u043c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0430.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u0422\u043e\u0447\u043d\u043e\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435<\/strong><br>\u041c\u044b \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u043b\u0438&nbsp;<strong>38 \u0435\u0434\u0438\u043d\u0438\u0446 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u043e\u043f\u043e\u0440\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 50 \u043a\u0412\u0410<\/strong>&nbsp;(\u043c\u043e\u0434\u0435\u043b\u044c D-50\/13.2). \u041a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f:<\/strong>\u00a0\u0412\u044b\u0441\u043e\u043a\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 13200Y\/7620 \u0412 \u043a \u043d\u0438\u0437\u043a\u043e\u043c\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e 120\/240 \u0412.<\/li>\n\n\n\n<li><strong>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b \u043e\u0431\u043c\u043e\u0442\u043e\u043a:<\/strong>\u00a0\u0412\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u043c\u0435\u0434\u044c (Cu\/Cu) \u0434\u043b\u044f \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0438 \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u0438.<\/li>\n\n\n\n<li><strong>\u0421\u0438\u0441\u0442\u0435\u043c\u0430 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f:<\/strong>\u00a0\u0422\u0438\u043f ONAN (\u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u043c\u0430\u0441\u043b\u044f\u043d\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u0438 \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435) \u0441 \u043c\u0438\u043d\u0435\u0440\u0430\u043b\u044c\u043d\u044b\u043c \u043c\u0430\u0441\u043b\u043e\u043c, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u0430\u044f \u043d\u0430 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0434\u043e 65 \u00b0C.<\/li>\n\n\n\n<li><strong>\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c:<\/strong>\u00a0\u041e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u044b \u043a\u043b\u0430\u043f\u0430\u043d\u0430\u043c\u0438 \u0441\u0431\u0440\u043e\u0441\u0430 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u043c\u0438 \u043f\u0440\u043e\u0445\u043e\u0434\u043d\u044b\u043c\u0438 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430\u043c\u0438, \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0430\u0434\u0430\u043f\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u043d\u0430 \u043e\u043f\u043e\u0440\u0430\u0445.<\/li>\n<\/ul>\n\n\n<div class=\"gb-container gb-container-3985f2cb\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-306f50ff\">\n<div class=\"gb-grid-column gb-grid-column-68fb26c3\"><div class=\"gb-container gb-container-68fb26c3\">\n\n<figure class=\"gb-block-image gb-block-image-4cb23278\"><img loading=\"lazy\" decoding=\"async\" width=\"1140\" height=\"810\" class=\"gb-image gb-image-4cb23278\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2.webp\" alt=\"\" title=\"\u041e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0435 \u043e\u043f\u043e\u0440\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u0430\u0445, \u043f\u0440\u043e\u0435\u043a\u04422\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2.webp 1140w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-300x213.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-1024x728.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-768x546.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-18x12.webp 18w\" sizes=\"auto, (max-width: 1140px) 100vw, 1140px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-525a89c3\"><div class=\"gb-container gb-container-525a89c3\">\n\n<figure class=\"gb-block-image gb-block-image-a3b67144\"><img loading=\"lazy\" decoding=\"async\" width=\"1140\" height=\"810\" class=\"gb-image gb-image-a3b67144\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1.webp\" alt=\"\" title=\"\u041e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0435 \u043e\u043f\u043e\u0440\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u0430\u0445, \u043f\u0440\u043e\u0435\u043a\u04421\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1.webp 1140w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-300x213.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-1024x728.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-768x546.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-18x12.webp 18w\" sizes=\"auto, (max-width: 1140px) 100vw, 1140px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430<\/strong><br>\u041f\u0435\u0440\u0435\u0434 \u043e\u0442\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u043a\u0430\u0436\u0434\u0430\u044f \u0435\u0434\u0438\u043d\u0438\u0446\u0430 \u043f\u0440\u043e\u0448\u043b\u0430 \u0441\u0442\u0440\u043e\u0433\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043d\u0430\u0448\u0435\u043c \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u0438, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u0430 (\u043f\u0440\u0438 85 \u00b0C), \u043f\u043e\u0442\u0435\u0440\u044c \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u0438 \u0445\u043e\u043b\u043e\u0441\u0442\u043e\u0433\u043e \u0445\u043e\u0434\u0430, \u0447\u0442\u043e \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u043c\u044b\u043c \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u043e\u043c \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044f\u043c \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0417\u0430 \u043a\u0430\u0434\u0440\u043e\u043c: \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u0438 \u043c\u0430\u0441\u0442\u0435\u0440\u0441\u0442\u0432\u043e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041a\u0430\u043a \u0432\u0438\u0434\u043d\u043e \u043d\u0430 \u043d\u0430\u0448\u0438\u0445 \u0432\u0438\u0434\u0435\u043e\u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430, \u043a\u0430\u0436\u0434\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0432 \u0434\u0430\u043d\u043d\u043e\u043c \u0437\u0430\u043a\u0430\u0437\u0435 \u043f\u0440\u043e\u0448\u0451\u043b \u0442\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0446\u0438\u043a\u043b \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f. \u041e\u0442 \u0442\u043e\u0447\u043d\u043e\u0439 \u043d\u0430\u043c\u043e\u0442\u043a\u0438 \u043e\u0431\u043c\u043e\u0442\u043e\u043a \u0434\u043e \u0441\u0431\u043e\u0440\u043a\u0438 \u043c\u0430\u0433\u043d\u0438\u0442\u043e\u043f\u0440\u043e\u0432\u043e\u0434\u0430 \u0438 \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0432 \u0431\u0430\u043a\u0435 \u043d\u0430\u0448\u0430 \u043a\u043e\u043c\u0430\u043d\u0434\u0430 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u043b\u0430 \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u0432\u0441\u0435\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441\u043e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u0444\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u0441\u043a\u043e\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438 \u043f\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n<div class=\"gb-container gb-container-914221ed\">\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"\u041e\u043f\u043e\u0440\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 Tengyi \u2014 \u043e\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0434\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u043e\u0439\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/-v8OE7XILHk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">\u0421\u0442\u0440\u043e\u0433\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f: \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u0441\u0442\u0432\u0430<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u043b\u044e\u0431\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043f\u043e\u043a\u0438\u043d\u0435\u0442 \u043d\u0430\u0448 \u0437\u0430\u0432\u043e\u0434, \u043e\u043d\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u044c \u0441\u0432\u043e\u044e \u043d\u0430\u0434\u0451\u0436\u043d\u043e\u0441\u0442\u044c. \u0414\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u0437\u0430\u043a\u0430\u0437\u0430 \u0438\u0437 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d \u043c\u044b \u043f\u0440\u043e\u0432\u0435\u043b\u0438 \u0440\u0443\u0442\u0438\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f 100% \u043d\u0430 \u043a\u0430\u0436\u0434\u043e\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0435.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u041a\u0430\u043a \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043e \u0432 \u043d\u0430\u0448\u0435\u0439 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0426\u0438\u0444\u0440\u043e\u0432\u0430\u044f \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c:<\/strong>&nbsp;\u041c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043b\u0438 \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u0435 \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440\u044b \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438, \u043f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u0438 \u0438 \u0443\u0433\u043b\u0430 \u0441\u0434\u0432\u0438\u0433\u0430 \u0444\u0430\u0437.<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0440\u0430\u0431\u043e\u0447\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a:<\/strong>&nbsp;\u041f\u043e\u0442\u0435\u0440\u0438 \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u0438 \u0445\u043e\u043b\u043e\u0441\u0442\u043e\u0433\u043e \u0445\u043e\u0434\u0430 \u0441\u0442\u0440\u043e\u0433\u043e \u0438\u0437\u043c\u0435\u0440\u044f\u043b\u0438\u0441\u044c \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438.<\/li>\n\n\n\n<li><strong>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438:<\/strong>&nbsp;\u0411\u044b\u043b\u0438 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u0434\u043b\u044f \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u041b\u0438\u0448\u044c \u043f\u043e\u0441\u043b\u0435 \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f \u044d\u0442\u0438\u0445 \u0441\u0442\u0440\u043e\u0433\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0431\u044b\u043b\u0438 \u043e\u0434\u043e\u0431\u0440\u0435\u043d\u044b \u043a \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0435.<\/p>\n\n\n<div class=\"gb-container gb-container-d1dc6f35\">\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u043e\u0433\u043e \u043e\u043f\u043e\u0440\u043d\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 Tengyi\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/9cDyBP8TUks?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-292aeac9\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-518a1e52\">\n<div class=\"gb-grid-column gb-grid-column-cdcc536c\"><div class=\"gb-container gb-container-cdcc536c\">\n\n<h3 class=\"wp-block-heading\">\u041d\u0430\u0434\u0451\u0436\u043d\u0430\u044f \u043b\u043e\u0433\u0438\u0441\u0442\u0438\u043a\u0430<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0427\u0442\u043e\u0431\u044b \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0432 \u041c\u0430\u043d\u0438\u043b\u0443 \u0432 \u0431\u0435\u0437\u0443\u043f\u0440\u0435\u0447\u043d\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438, \u043c\u044b \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043b\u0438 \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u044b\u0435 \u0434\u0435\u0440\u0435\u0432\u044f\u043d\u043d\u044b\u0435 \u044f\u0449\u0438\u043a\u0438, \u043e\u043f\u0442\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u043f\u043e\u0433\u0440\u0443\u0437\u043a\u0438 \u0432 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u044b. \u041a\u0430\u043a \u0432\u0438\u0434\u043d\u043e \u043d\u0430 \u0444\u043e\u0442\u043e\u0433\u0440\u0430\u0444\u0438\u044f\u0445 \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438, \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043d\u0430\u0434\u0451\u0436\u043d\u043e \u0443\u043b\u043e\u0436\u0435\u043d\u044b \u0432\u043d\u0443\u0442\u0440\u0438 40-\u0444\u0443\u0442\u043e\u0432\u043e\u0433\u043e \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0430 (40HQ), \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043c\u043e\u0440\u0441\u043a\u043e\u0439 \u043f\u0435\u0440\u0435\u0432\u043e\u0437\u043a\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0413\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u043e\u0435 \u0434\u043e\u0432\u0435\u0440\u0438\u0435, \u043c\u0435\u0441\u0442\u043d\u0430\u044f \u043f\u0440\u0438\u0432\u0435\u0440\u0436\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u043e\u0442 \u0442\u043e\u0433\u043e, \u043f\u0440\u0438\u043d\u0438\u043c\u0430\u0435\u043c \u043b\u0438 \u043c\u044b \u043d\u043e\u0432\u044b\u0445 \u043f\u0430\u0440\u0442\u043d\u0451\u0440\u043e\u0432 \u043d\u0430 \u044d\u043a\u0441\u043a\u0443\u0440\u0441\u0438\u0438 \u043f\u043e \u0437\u0430\u0432\u043e\u0434\u0443 \u0438\u043b\u0438 \u043e\u0442\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u043c \u043f\u043e\u043b\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u044b \u043e\u043f\u044b\u0442\u043d\u044b\u043c \u0443\u0447\u0430\u0441\u0442\u043d\u0438\u043a\u0430\u043c \u0440\u044b\u043d\u043a\u0430 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u0430\u0445, Tengyi \u043e\u0441\u0442\u0430\u0451\u0442\u0441\u044f \u043f\u0440\u0438\u0432\u0435\u0440\u0436\u0435\u043d\u0430 \u0434\u0435\u043b\u0443 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043c\u0438\u0440\u0430 \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u043c\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0440\u0435\u0448\u0435\u043d\u0438\u044f\u043c\u0438.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f2d5875f\"><div class=\"gb-container gb-container-f2d5875f\">\n<div class=\"gb-container gb-container-97dbf4e6\">\n\n<figure class=\"gb-block-image gb-block-image-af7cab49\"><img loading=\"lazy\" decoding=\"async\" width=\"998\" height=\"979\" class=\"gb-image gb-image-af7cab49\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp\" alt=\"\" title=\"\u041e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp 998w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-300x294.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-768x753.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-12x12.webp 12w\" sizes=\"auto, (max-width: 998px) 100vw, 998px\" \/><\/figure>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b884af38\">\n<div class=\"gb-container gb-container-0d997913\">\n<div class=\"gb-container gb-container-12d6c45c\">\n<div class=\"gb-container gb-container-e4b92954\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-c263af85\">\n<div class=\"gb-grid-column gb-grid-column-be74dc72\"><div class=\"gb-container gb-container-be74dc72\">\n\n<p class=\"gb-headline gb-headline-a01f4858 gb-headline-text\">\u0421\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u0441 \u043d\u0430\u0448\u0438\u043c\u0438 \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u0430\u043c\u0438, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043b\u0443\u0447\u0448\u0443\u044e \u0446\u0435\u043d\u0443 \u043e\u0442 \u0437\u0430\u0432\u043e\u0434\u0430-\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u041d\u0430\u0448\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u044b \u0441 \u0443\u0447\u0451\u0442\u043e\u043c \u0432\u0430\u0448\u0438\u0445 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u0447\u0430\u0441\u0442\u043e\u0442\u0435 \u0441\u0435\u0442\u0438 \u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u0421\u043e\u0442\u0440\u0443\u0434\u043d\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441 Tengyi \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0432\u0430\u043c \u0440\u0435\u0448\u0435\u043d\u0438\u044f, \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0435 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u0443\u044e \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c \u043e\u0431\u043c\u043e\u0442\u043e\u043a \u0438\u0437 \u043c\u0435\u0434\u0438, \u0441\u0442\u0440\u043e\u0433\u043e\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c IEEE \u0438 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u044b\u0445 \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0443 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u043e\u0432.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-3726250d\"><div class=\"gb-container gb-container-3726250d\">\n<div class=\"gb-container gb-container-4f0d8dd7\">\n\n<a class=\"gb-button gb-button-7d9b861c gb-button-text\" href=\"#popmake-561\">\u041f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u0431\u0435\u0441\u043f\u043b\u0430\u0442\u043d\u043e\u0435 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u041f\u043e\u043b\u043d\u0430\u044f \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0432 40-\u0444\u0443\u0442\u043e\u0432\u043e\u043c \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0435 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043c\u044b \u0443\u0441\u043f\u0435\u0448\u043d\u043e \u0437\u0430\u0433\u0440\u0443\u0437\u0438\u043b\u0438 \u0438 \u043e\u0442\u043f\u0440\u0430\u0432\u0438\u043b\u0438 <strong>\u043f\u043e\u043b\u043d\u044b\u0439 40-\u0444\u0443\u0442\u043e\u0432\u044b\u0439 \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440<\/strong> \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u043e\u043f\u043e\u0440\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432, \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u043d\u044b\u0445 \u0434\u043b\u044f <strong>\u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d<\/strong>. \u041e\u0431\u0437\u043e\u0440 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438: \u041a\u043e\u0433\u0434\u0430 \u0432\u0435\u0434\u0443\u0449\u0438\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440 \u2026 <\/p>\n<p class=\"read-more-container\"><a title=\"\u041f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/ru\/single-phase-transformers-delivery-to-the-philippines\/#more-1811\" aria-label=\"\u041f\u043e\u0434\u0440\u043e\u0431\u043d\u0435\u0435 \u043e \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0435 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b\">\u0427\u0438\u0442\u0430\u0439\u0442\u0435 \u0434\u0430\u043b\u044c\u0448\u0435<\/a><\/p>","protected":false},"author":2,"featured_media":1813,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cases","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Single Phase Transformers Delivery to the Philippines - Tengyi Electric<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single Phase Transformers Delivery to the Philippines - Tengyi Electric\" \/>\n<meta property=\"og:description\" content=\"Full 40-Foot Container Single Phase Transformers Delivery to the Philippines Today, we successfully loaded and shipped a&nbsp;full 40ft High Cube Container&nbsp;of Single-Phase Pole Mounted Transformers destined for the&nbsp;Philippines. Product Overview When a leading electrical distributor ... \u0427\u0438\u0442\u0430\u0442\u044c \u0434\u0430\u043b\u0435\u0435\" \/>\n<meta property=\"og:url\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-19T06:11:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-22T08:48:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.png\" \/>\n\t<meta property=\"og:image:width\" content=\"998\" \/>\n\t<meta property=\"og:image:height\" content=\"979\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"TYElectric\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"TYElectric\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"},\"author\":{\"name\":\"TYElectric\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\"},\"headline\":\"Single Phase Transformers Delivery to the Philippines\",\"datePublished\":\"2025-12-19T06:11:49+00:00\",\"dateModified\":\"2025-12-22T08:48:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"},\"wordCount\":523,\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"articleSection\":[\"Cases\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\",\"name\":\"Single Phase Transformers Delivery to the Philippines - Tengyi Electric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"datePublished\":\"2025-12-19T06:11:49+00:00\",\"dateModified\":\"2025-12-22T08:48:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"width\":998,\"height\":979},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single Phase Transformers Delivery to the Philippines\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\",\"name\":\"TYElectric\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"caption\":\"TYElectric\"},\"url\":\"https:\\\/\\\/tengyielectric.com\\\/ru\\\/author\\\/tyelectric\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u041f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b \u2014 Tengyi Electric","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","og_locale":"ru_RU","og_type":"article","og_title":"Single Phase Transformers Delivery to the Philippines - Tengyi Electric","og_description":"Full 40-Foot Container Single Phase Transformers Delivery to the Philippines Today, we successfully loaded and shipped a&nbsp;full 40ft High Cube Container&nbsp;of Single-Phase Pole Mounted Transformers destined for the&nbsp;Philippines. Product Overview When a leading electrical distributor ... \u0427\u0438\u0442\u0430\u0442\u044c \u0434\u0430\u043b\u0435\u0435","og_url":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","og_site_name":"Tengyi Electric","article_published_time":"2025-12-19T06:11:49+00:00","article_modified_time":"2025-12-22T08:48:13+00:00","og_image":[{"width":998,"height":979,"url":"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.png","type":"image\/png"}],"author":"TYElectric","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"TYElectric","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"2 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#article","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"},"author":{"name":"TYElectric","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896"},"headline":"Single Phase Transformers Delivery to the Philippines","datePublished":"2025-12-19T06:11:49+00:00","dateModified":"2025-12-22T08:48:13+00:00","mainEntityOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"},"wordCount":523,"publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","articleSection":["Cases"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","name":"\u041f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0424\u0438\u043b\u0438\u043f\u043f\u0438\u043d\u044b \u2014 Tengyi Electric","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","datePublished":"2025-12-19T06:11:49+00:00","dateModified":"2025-12-22T08:48:13+00:00","breadcrumb":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","width":998,"height":979},{"@type":"BreadcrumbList","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Single Phase Transformers Delivery to the Philippines"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u00ab\u0422\u044d\u043d\u044a\u0438\u00bb","description":"\u0412\u0435\u0434\u0443\u0449\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u043d\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u00ab\u0422\u044d\u043d\u044a\u0438\u00bb","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896","name":"TYElectric","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","caption":"TYElectric"},"url":"https:\/\/tengyielectric.com\/ru\/author\/tyelectric\/"}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/posts\/1811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/comments?post=1811"}],"version-history":[{"count":0,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/posts\/1811\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/media\/1813"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/media?parent=1811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/categories?post=1811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/tags?post=1811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}