{"id":1008,"date":"2025-01-24T16:38:59","date_gmt":"2025-01-24T08:38:59","guid":{"rendered":"https:\/\/s3jnrqxbrg.onrocket.site\/?page_id=1008"},"modified":"2026-10-29T14:26:57","modified_gmt":"2026-10-29T06:26:57","slug":"%d1%80%d0%b0%d1%81%d0%bf%d1%80%d0%b5%d0%b4%d0%b5%d0%bb%d0%b8%d1%82%d0%b5%d0%bb%d1%8c%d0%bd%d1%8b%d0%b9-%d1%82%d1%80%d0%b0%d0%bd%d1%81%d1%84%d0%be%d1%80%d0%bc%d0%b0%d1%82%d0%be%d1%80","status":"publish","type":"page","link":"https:\/\/tengyielectric.com\/ru\/distribution-transformer\/","title":{"rendered":"\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440"},"content":{"rendered":"<div class=\"gb-container gb-container-f2d0df70\">\n<div class=\"gb-container gb-container-87b37709\">\n<div class=\"gb-container gb-container-f70d84af\">\n\n<h1 class=\"gb-headline gb-headline-c3ead352 gb-headline-text\">Distribution Transformer<\/h1>\n\n\n\n<p class=\"gb-headline gb-headline-1c44214b gb-headline-text\">Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9bedf81d\">\n<div class=\"gb-container gb-container-e46be8ee\">\n<div class=\"gb-container gb-container-b23703f4\">\n<div class=\"gb-container gb-container-66b9cb03\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-eaf06577\">\n<div class=\"gb-grid-column gb-grid-column-93eece37\"><div class=\"gb-container gb-container-93eece37\">\n<div class=\"gb-container gb-container-f69fb4aa\">\n\n\t\t<!-- MasterSlider -->\n\t\t<div id=\"P_MS6b00b3cbdd47e\" class=\"master-slider-parent msl ms-parent-id-5\" style=\"max-width:800px;\">\n\n\t\t\t\n\t\t\t<!-- MasterSlider Main -->\n\t\t\t<div id=\"MS6b00b3cbdd47e\" class=\"master-slider ms-skin-default\" >\n\t\t\t\t \t\t\t\t \n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-sale.png\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-sale-140x80.png\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer1.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer1-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer2.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer2-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer8.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer8-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer5.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer5-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer3.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer3-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer4.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer4-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer6.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer6-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer7.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer7-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\n\t\t\t<\/div>\n\t\t\t<!-- END MasterSlider Main -->\n\n\t\t\t \n\t\t<\/div>\n\t\t<!-- END MasterSlider -->\n\n\t\t<script>\n\t\t(function ( $ ) {\n\t\t\t\"use strict\";\n\n\t\t\t$(function () {\n\t\t\t\tvar masterslider_d47e = new MasterSlider();\n\n\t\t\t\t\/\/ slider controls\n\t\t\t\tmasterslider_d47e.control('arrows'     ,{ autohide:false, overVideo:true  });\t\t\t\tmasterslider_d47e.control('bullets'    ,{ autohide:false, overVideo:true, dir:'h', align:'bottom' , margin:10  });\n\n\t\t\t\tmasterslider_d47e.control('thumblist'  ,{ autohide:false, overVideo:true, dir:'h', speed:17, inset:false, arrows:false, hover:false, customClass:'', align:'bottom',type:'thumbs', margin:5, width:140, height:80, space:5, fillMode:'fill'  });\n\t\t\t\t\/\/ slider setup\n\t\t\t\tmasterslider_d47e.setup(\"MS6b00b3cbdd47e\", {\n\t\t\t\t\t\twidth           : 650,\n\t\t\t\t\t\theight          : 630,\n\t\t\t\t\t\tminHeight       : 0,\n\t\t\t\t\t\tspace           : 0,\n\t\t\t\t\t\tstart           : 1,\n\t\t\t\t\t\tgrabCursor      : true,\n\t\t\t\t\t\tswipe           : true,\n\t\t\t\t\t\tmouse           : true,\n\t\t\t\t\t\tlayout          : \"boxed\",\n\t\t\t\t\t\twheel           : false,\n\t\t\t\t\t\tautoplay        : true,\n\t\t\t\t\t\tinstantStartLayers:false,\n\t\t\t\t\t\tloop            : true,\n\t\t\t\t\t\tshuffle         : false,\n\t\t\t\t\t\tpreload         : 0,\n\t\t\t\t\t\theightLimit     : true,\n\t\t\t\t\t\tautoHeight      : false,\n\t\t\t\t\t\tsmoothHeight    : true,\n\t\t\t\t\t\tendPause        : false,\n\t\t\t\t\t\toverPause       : true,\n\t\t\t\t\t\tfillMode        : \"fill\",\n\t\t\t\t\t\tcenterControls  : true,\n\t\t\t\t\t\tstartOnAppear   : false,\n\t\t\t\t\t\tlayersMode      : \"center\",\n\t\t\t\t\t\thideLayers      : false,\n\t\t\t\t\t\tfullscreenMargin: 0,\n\t\t\t\t\t\tspeed           : 20,\n\t\t\t\t\t\tdir             : \"h\",\n\t\t\t\t\t\tparallaxMode    : 'swipe',\n\t\t\t\t\t\tview            : \"basic\"\n\t\t\t\t});\n\n\t\t\t\t\n\t\t\t\twindow.masterslider_instances = window.masterslider_instances || [];\n\t\t\t\twindow.masterslider_instances.push( masterslider_d47e );\n\t\t\t });\n\n\t\t})(jQuery);\n\t\t<\/script>\n\n\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb3dfde6\"><div class=\"gb-container gb-container-eb3dfde6\">\n<div class=\"gb-container gb-container-4e1a0988\">\n\n<h2 class=\"gb-headline gb-headline-7258d199 gb-headline-text\">Distribution Transformer For Sale<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Our distribution transformers utilize advanced technology to maximize high-voltage power step-down efficiency, minimizing energy transmission losses.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-da7dd2b7 gb-headline-text\">It is essential for stepping down high voltage electricity from substations to lower voltages suitable for residential, commercial and industrial use.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d8ebb883 gb-headline-text\">Main Parameters<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-27ca91ab\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Power rating:<\/strong> 10-20000 kVA<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-012f0c5f\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Primary voltage: <\/strong>6-11 kV<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be479e67\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Secondary voltage: <\/strong>400V; 690V<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-838d3be8 gb-headline-text\">Working Conditions<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-cca7f3b7\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Altitude should not exceed 1000 meters<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9a54171d\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Operating environment temperature should be between -25\u2103 and +40\u2103<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-05779465\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The relative humidity should not exceed 90%(+25\u2103\uff09<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-56dd8c24\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The vertical inclination does not exceed 5\u00b0.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-2dceb606\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The outdoor wind speed does not exceed 35m\/s.<\/span><\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-bf2c2659\">\n\n<a class=\"gb-button gb-button-67c92043 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b5b41c7b\">\n<div class=\"gb-container gb-container-07e5685b\">\n<div class=\"gb-container gb-container-b4e2f617\">\n<div class=\"gb-container gb-container-c9a81447\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-22869477\">\n<div class=\"gb-grid-column gb-grid-column-d879e1c7\"><div class=\"gb-container gb-container-d879e1c7\">\n\n<h3 class=\"gb-headline gb-headline-9e33cb5f gb-headline-text\">S11 Low Loss Non-Exciting Regulation Transformer<\/h3>\n\n\n\n<figure class=\"gb-block-image gb-block-image-e4a12b05\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"630\" class=\"gb-image gb-image-e4a12b05\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp\" alt=\"\" title=\"s11-distribution-transformer\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp 650w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer-300x291.webp 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-a955e242\">\n\n<a class=\"gb-button gb-button-d418704d gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-590de754\"><div class=\"gb-container gb-container-590de754\">\n\n<h3 class=\"gb-headline gb-headline-a2803ccf gb-headline-text\">S11 MTZ On-Load Automatic Tuning Capacitor<\/h3>\n\n\n\n<figure class=\"gb-block-image gb-block-image-b2bf057c\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"630\" class=\"gb-image gb-image-b2bf057c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-mzt-distribution-transformer.webp\" alt=\"\" title=\"s11-mzt-distribution-transformer\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-mzt-distribution-transformer.webp 650w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-mzt-distribution-transformer-300x291.webp 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-efaa4db2\">\n\n<a class=\"gb-button gb-button-4bfb3a33 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-20319706\"><div class=\"gb-container gb-container-20319706\">\n\n<h3 class=\"gb-headline gb-headline-8d0deb55 gb-headline-text\">SZ11 Low Loss On-Load Regulation Transformer<\/h3>\n\n\n\n<figure class=\"gb-block-image gb-block-image-59cc1c43\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"630\" class=\"gb-image gb-image-59cc1c43\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/sz11-on-load-distribution-transformer.webp\" alt=\"\" title=\"sz11-on-load-distribution-transformer\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/sz11-on-load-distribution-transformer.webp 650w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/sz11-on-load-distribution-transformer-300x291.webp 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-de60097d\">\n\n<a class=\"gb-button gb-button-1386f1ad gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-92e0c466\">\n<div class=\"gb-container gb-container-018f91a0\">\n<div class=\"gb-container gb-container-d0d4194c\">\n\n<h2 class=\"gb-headline gb-headline-72c1a7bd gb-headline-text\">Tengyi Distribution Transformer Advantages<\/h2>\n\n\n<div class=\"gb-container gb-container-8645fb41\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-096ad6d8\">\n<div class=\"gb-grid-column gb-grid-column-28d68822\"><div class=\"gb-container gb-container-28d68822\">\n<div class=\"gb-container gb-container-c184f74c box-shadow\">\n<div class=\"gb-container gb-container-8d33aa0c\">\n\n<h3 class=\"gb-headline gb-headline-3e36ab2b\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>Premium Low-Voltage Design<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-703d9ad4 gb-headline-text\">Utilizing low-voltage copper foil winding with high-quality Class A insulation materials results in superior dielectric strength and long-term reliability.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb4ce9ec\"><div class=\"gb-container gb-container-eb4ce9ec\">\n<div class=\"gb-container gb-container-369e45f4 box-shadow\">\n<div class=\"gb-container gb-container-825a954d\">\n\n<h3 class=\"gb-headline gb-headline-8f6f5716\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>High Mechanical Strength<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-a6ec4c2c gb-headline-text\">The transformer&#8217;s low leakage flux and robust construction provide exceptional mechanical strength and superior short-circuit withstand capability.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-848ab375\"><div class=\"gb-container gb-container-848ab375\">\n<div class=\"gb-container gb-container-2b0a1ce0 box-shadow\">\n<div class=\"gb-container gb-container-d9a5bba3\">\n\n<h3 class=\"gb-headline gb-headline-2d8a461e\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>Advanced Core Structure<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-866cce29 gb-headline-text\">The 45\u00b0 full-skew stepped lamination core structure minimizes core losses, reducing noise and improving overall energy efficiency.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-a5ad70ad\"><div class=\"gb-container gb-container-a5ad70ad\">\n<div class=\"gb-container gb-container-394eaaa3 box-shadow\">\n<div class=\"gb-container gb-container-107c6b9e\">\n\n<h3 class=\"gb-headline gb-headline-c8d655c4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>Superior Lightning Protection<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-e9b2e4ab gb-headline-text\">Tengyi utilizes high-voltage copper strip winding technology that significantly enhances the transformer&#8217;s resistance to lightning strikes, ensuring reliable operation in extreme weather, even in stormy conditions.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d4594f3\"><div class=\"gb-container gb-container-6d4594f3\">\n<div class=\"gb-container gb-container-86db63c4 box-shadow\">\n<div class=\"gb-container gb-container-9d0a8965\">\n\n<h3 class=\"gb-headline gb-headline-40be9ad4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>Optimized Core Material<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-d30e367f gb-headline-text\">The use of high-quality cold-rolled grain-oriented silicon steel from reputable sources (Baosteel, Wuhan Iron and Steel) ensures low core losses, resulting in enhanced energy efficiency and reduced operating costs.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f6923e84\"><div class=\"gb-container gb-container-f6923e84\">\n<div class=\"gb-container gb-container-d33107a7 box-shadow\">\n<div class=\"gb-container gb-container-eb8fa6f4\">\n\n<h3 class=\"gb-headline gb-headline-42815d27\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>Superior Winding Insulation<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-1ef1ca4a gb-headline-text\">The combination of copper foil (low voltage) and specialized insulated copper wire (high voltage) windings, along with superior insulation materials, ensures excellent dielectric strength and prevents insulation breakdown.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f9e68e6b\">\n\n<a class=\"gb-button gb-button-ef0351a3 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-6fcd151c\">\n<div class=\"gb-container gb-container-6e3ddcdc\">\n<div class=\"gb-container gb-container-8dc4b63d\">\n\n<h2 class=\"gb-headline gb-headline-acf3b302 gb-headline-text\">10 kV, 1600kVA Distribution Transformer Design<\/h2>\n\n\n\n<figure class=\"gb-block-image gb-block-image-e03afde8\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1818\" class=\"gb-image gb-image-e03afde8\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-scaled.webp\" alt=\"\" title=\"1600kva-distribution-transformers-design\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-scaled.webp 2560w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-300x213.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-1024x727.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-768x545.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-1536x1091.webp 1536w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/1600kva-distribution-transformers-design-2048x1454.webp 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<h2 class=\"gb-headline gb-headline-a31cd1ee gb-headline-text\">Specification<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Capacity<\/strong><\/td><td colspan=\"3\"><strong>Rated voltage &amp; Off-load tapping<\/strong><\/td><td rowspan=\"2\"><strong>Vector&nbsp;GroupSymbol<\/strong><\/td><td rowspan=\"2\"><strong>NO-load loss\uff08W\uff09<\/strong><\/td><td rowspan=\"2\"><strong>Load loss\uff08W\uff09<\/strong><\/td><td rowspan=\"2\"><strong>NO-load current(%)<\/strong><\/td><td rowspan=\"2\"><strong>Short circuit impedance(%)<\/strong><\/td><\/tr><tr><td><strong>H.V(kv)<\/strong><\/td><td><strong>High pressure<\/strong><br><strong>Tap range(%)<\/strong><\/td><td><strong>L.V(kv)<\/strong><\/td><\/tr><tr><td>30<\/td><td rowspan=\"19\">11 10.5<br>10 6.3<br>6&nbsp;<\/td><td rowspan=\"19\">\u00b15%<br>\u00b12&#215;2.5%<\/td><td rowspan=\"19\">0.4<br>0.69<\/td><td rowspan=\"19\">Dyn11<br>Yyn0<\/td><td>100<\/td><td>630\/600<\/td><td>1.5<\/td><td>4<\/td><\/tr><tr><td>50<\/td><td>130<\/td><td>910\/870<\/td><td>1.3<\/td><td>4<\/td><\/tr><tr><td>63<\/td><td>150<\/td><td>1090\/1040<\/td><td>1.2<\/td><td>4<\/td><\/tr><tr><td>80<\/td><td>180<\/td><td>1310\/1250<\/td><td>1.2<\/td><td>4<\/td><\/tr><tr><td>100<\/td><td>200<\/td><td>1580\/1500<\/td><td>1.1<\/td><td>4<\/td><\/tr><tr><td>125<\/td><td>240<\/td><td>1890\/1800<\/td><td>1.1<\/td><td>4<\/td><\/tr><tr><td>160<\/td><td>280<\/td><td>2310\/2200<\/td><td>1<\/td><td>4<\/td><\/tr><tr><td>200<\/td><td>340<\/td><td>2730\/2600<\/td><td>1<\/td><td>4<\/td><\/tr><tr><td>250<\/td><td>400<\/td><td>3200\/3050<\/td><td>0.9<\/td><td>4<\/td><\/tr><tr><td>315<\/td><td>480<\/td><td>3830\/3650<\/td><td>0.9<\/td><td>4<\/td><\/tr><tr><td>400<\/td><td>570<\/td><td>4520\/4300<\/td><td>0.8<\/td><td>4<\/td><\/tr><tr><td>500<\/td><td>680<\/td><td>5410\/5150<\/td><td>0.8<\/td><td>4<\/td><\/tr><tr><td>630<\/td><td>810<\/td><td>6200<\/td><td>0.6<\/td><td>4.5<\/td><\/tr><tr><td>800<\/td><td>980<\/td><td>7500<\/td><td>0.6<\/td><td>4.5<\/td><\/tr><tr><td>1000<\/td><td>1150<\/td><td>10300<\/td><td>0.6<\/td><td>4.5<\/td><\/tr><tr><td>1250<\/td><td>1360<\/td><td>12000<\/td><td>0.5<\/td><td>4.5<\/td><\/tr><tr><td>1600<\/td><td>1640<\/td><td>14500<\/td><td>0.5<\/td><td>4.5<\/td><\/tr><tr><td>2000<\/td><td>1940<\/td><td>18300<\/td><td>0.4<\/td><td>5<\/td><\/tr><tr><td>2500<\/td><td>2290<\/td><td>21200<\/td><td>0.4<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-140ded7c\">\n\n<a class=\"gb-button gb-button-09555e88 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f9554427\">\n<div class=\"gb-container gb-container-d4a876ee\">\n<div class=\"gb-container gb-container-727f4282\">\n\n<h2 class=\"gb-headline gb-headline-d97c1b74 gb-headline-text\">Type Test Report | 800 kVA Oil-Immersed Transformer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Review the type test report for sample model S20-M-800-0.4\/11-NX2, rated at 800 kVA, 11 kV\/0.4 kV, three-phase, 50 Hz, with ONAN cooling. The report lists the tests performed and the applicable standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test coverage<\/strong><br>Insulation and dielectric testing \u00b7 Loss measurement \u00b7 Temperature-rise testing \u00b7 Sound-level measurement \u00b7 Lightning-impulse testing \u00b7 Pressure and leakage testing \u00b7 Overload testing \u00b7 Short-circuit withstand testing<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Report scope<\/strong><br>This report applies only to the tested sample identified in the document. Contact Tengyi to confirm test reports and compliance documents for other models or project specifications.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/10\/Tengyi-S20-M-800-0.4-11-NX2-Test-Report.pdf\" type=\"application\/pdf\" style=\"width:100%;height:800px\" aria-label=\"\u0412\u0441\u0442\u0430\u0432\u043a\u0430 Tengyi S20-M-800-0.4-11-NX2 Test Report\"><\/object><a id=\"wp-block-file--media-1eb72d60-8ae0-44b7-a5ff-859595cb354f\" href=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/10\/Tengyi-S20-M-800-0.4-11-NX2-Test-Report.pdf\">Tengyi S20-M-800-0.4-11-NX2 Test Report<\/a><\/div>\n\n\n<div class=\"gb-container gb-container-93362ba0\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-019de64c\">\n<div class=\"gb-grid-column gb-grid-column-cf03fdc9\"><div class=\"gb-container gb-container-cf03fdc9\">\n<div class=\"gb-container gb-container-e6063651\">\n\n<a class=\"gb-button gb-button-afc96139 gb-button-text\" href=\"#popmake-571\">Request Documents For Your Spec<\/a>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-35720f9d\"><div class=\"gb-container gb-container-35720f9d\">\n<div class=\"gb-container gb-container-9c1d220e\">\n\n<a class=\"gb-button gb-button-294f8177 gb-button-text\" href=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/10\/Tengyi-S20-M-800-0.4-11-NX2-Test-Report.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">View Tengyi Type Test Report<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fbd03688\">\n<div class=\"gb-container gb-container-bffb56fe\">\n<div class=\"gb-container gb-container-a99e2155\">\n<div class=\"gb-container gb-container-3f80dc29\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-90995f9e\">\n<div class=\"gb-grid-column gb-grid-column-73686e68\"><div class=\"gb-container gb-container-73686e68\">\n<div class=\"gb-container gb-container-3eb15824\">\n\n<figure class=\"wp-block-video\"><video height=\"480\" style=\"aspect-ratio: 854 \/ 480;\" width=\"854\" controls loop src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/tengyi-factory.mp4\"><\/video><\/figure>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-e7736112\"><div class=\"gb-container gb-container-e7736112\">\n<div class=\"gb-container gb-container-d01331a5\">\n\n<h2 class=\"gb-headline gb-headline-874b23bf gb-headline-text\">About Tengyi<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-95857e0e gb-headline-text\">We are a premier enterprise specialising in designing, manufacturing, and testing a wide array of transformers.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-f932b516 gb-headline-text\">Our advanced production facility covers over 11,000 square meters and features a maximum lifting capacity of 240 tons, allowing us to achieve an impressive annual production capacity of 12,000 MVA.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be10ada1 gb-headline-text\">We provide transformers suitable for voltage ranges from 52 to 800 kV, with power ratings from 20 to 600 MVA, and our auto-transformers can reach capacities of up to 1,000 MVA.<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b31aff1d\">\n<div class=\"gb-container gb-container-0ff21d27\">\n<div class=\"gb-container gb-container-9ff863bf\">\n\n<h2 class=\"gb-headline gb-headline-166863e7 gb-headline-text\">Global Cases<\/h2>\n\n\n<div class=\"gb-container gb-container-92c8f335\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4d8d49be\">\n<div class=\"gb-grid-column gb-grid-column-68f270f9\"><div class=\"gb-container gb-container-68f270f9 box-shadow\">\n<div class=\"gb-container gb-container-f1a7aefb\">\n<div class=\"gb-container gb-container-deb3708a\">\n\n<figure class=\"gb-block-image gb-block-image-4cc7c578\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-4cc7c578\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case4.webp\" alt=\"\" title=\"distribution-transformer-case4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case4.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case4-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-8d95318d\">\n\n<p class=\"gb-headline gb-headline-67aa1354 gb-headline-text\"><strong>Distribution Transformer Operation in Kazakhstan<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b3be5d52\"><div class=\"gb-container gb-container-b3be5d52 box-shadow\">\n<div class=\"gb-container gb-container-6f6a573f\">\n<div class=\"gb-container gb-container-486e91c5\">\n\n<figure class=\"gb-block-image gb-block-image-1b33d975\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-1b33d975\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case1.webp\" alt=\"\" title=\"distribution-transformer-case1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case1.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case1-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ac40903a\">\n\n<p class=\"gb-headline gb-headline-f5dae651 gb-headline-text\"><strong><strong>Distribution<\/strong> Transformer Installed in Ghana <\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-5b43e0ba\"><div class=\"gb-container gb-container-5b43e0ba box-shadow\">\n<div class=\"gb-container gb-container-252edb0d\">\n<div class=\"gb-container gb-container-71061808\">\n\n<figure class=\"gb-block-image gb-block-image-c50e0c59\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-c50e0c59\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case3.webp\" alt=\"\" title=\"distribution-transformer-case3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case3.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case3-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-639c032c\">\n\n<p class=\"gb-headline gb-headline-3ab9e394 gb-headline-text\"><strong><strong>Distribution<\/strong> Transformer Operation in Lybia<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-568b7687\"><div class=\"gb-container gb-container-568b7687 box-shadow\">\n<div class=\"gb-container gb-container-720db38c\">\n<div class=\"gb-container gb-container-807afc16\">\n\n<figure class=\"gb-block-image gb-block-image-e6413539\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-e6413539\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case2.webp\" alt=\"\" title=\"distribution-transformer-case2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case2.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-case2-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ae140dd6\">\n\n<p class=\"gb-headline gb-headline-58ea974c gb-headline-text\"><strong>Box Type <strong>Distribution<\/strong><\/strong> <strong>Transformer in Kenya<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-93bd4d7a\">\n\n<a class=\"gb-button gb-button-268bab37 gb-button-text\" href=\"#popmake-573\">Customize Your Projects<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9b106039\">\n<div class=\"gb-container gb-container-222eb79e\">\n<div class=\"gb-container gb-container-c267a5c3\">\n\n<h2 class=\"gb-headline gb-headline-269e49db gb-headline-text\">Customer Feedback<\/h2>\n\n\n<div class=\"gb-container gb-container-598617b6\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-a1cf8e8f\">\n<div class=\"gb-grid-column gb-grid-column-0876043a\"><div class=\"gb-container gb-container-0876043a box-shadow\">\n<div class=\"gb-container gb-container-cb854a33\">\n\n<p class=\"gb-headline gb-headline-a7e17eaa gb-headline-text\"><strong>Ivan Kibona<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&#8211; from Tanzania<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d5d293e6 gb-headline-text\">We&#8217;ve been using these Tengyi distribution transformers for the past five years at our industrial facility, and they&#8217;ve consistently exceeded expectations.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-2da8b305 gb-headline-text\">They&#8217;re incredibly reliable, requiring minimal maintenance. We&#8217;ve experienced zero downtime due to transformer failures. We&#8217;re very satisfied with the quality and performance of these units.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9408837f gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-defb5ca7\"><div class=\"gb-container gb-container-defb5ca7 box-shadow\">\n<div class=\"gb-container gb-container-f5ea4cf7\">\n\n<p class=\"gb-headline gb-headline-635a1ae5 gb-headline-text\"><strong>Eng. Adiel Karima<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&#8211; from Zimbabwe<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-39aca2b2 gb-headline-text\">The energy efficiency of these distribution transformers is truly impressive. Since switching to this new model, our energy bills have dropped considerably.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-c80a8612 gb-headline-text\">The reduced energy consumption is not only cost-effective but also contributes positively to our overall environmental sustainability goals. The transformer&#8217;s robust design and high-quality components clearly make a difference.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d438266a gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-a7c9826f\">\n<div class=\"gb-container gb-container-2d15f96e\">\n<div class=\"gb-container gb-container-b509a5ca\">\n\n<h2 class=\"gb-headline gb-headline-af18f263 gb-headline-text\">Distribution Transformer Workshop<\/h2>\n\n\n<div class=\"gb-container gb-container-afb8e67c\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-ec04d4c9\">\n<div class=\"gb-grid-column gb-grid-column-16bc3c39\"><div class=\"gb-container gb-container-16bc3c39\">\n\n<figure class=\"gb-block-image gb-block-image-4c25ac61\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4c25ac61\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop1.webp\" alt=\"\" title=\"distribution-transformer-workshop1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop1-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-cdac3a5c\"><div class=\"gb-container gb-container-cdac3a5c\">\n\n<figure class=\"gb-block-image gb-block-image-d1d511b7\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-d1d511b7\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop2.webp\" alt=\"\" title=\"distribution-transformer-workshop2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop2-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-83b1f304\"><div class=\"gb-container gb-container-83b1f304\">\n\n<figure class=\"gb-block-image gb-block-image-9595ad8a\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-9595ad8a\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop3.webp\" alt=\"\" title=\"distribution-transformer-workshop3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop3.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop3-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-0f93ff24\"><div class=\"gb-container gb-container-0f93ff24\">\n\n<figure class=\"gb-block-image gb-block-image-4f95db6c\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4f95db6c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop4.webp\" alt=\"\" title=\"distribution-transformer-workshop4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop4.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-workshop4-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fe8bf9b8\">\n<div class=\"gb-container gb-container-5d653b1e\">\n<div class=\"gb-container gb-container-177ab65c\">\n\n<h2 class=\"gb-headline gb-headline-db58d5b7 gb-headline-text\">Distribution Transformer Production Details<\/h2>\n\n\n<div class=\"gb-container gb-container-0320fa24\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-3e7d62cb\">\n<div class=\"gb-grid-column gb-grid-column-68e263cc\"><div class=\"gb-container gb-container-68e263cc\">\n\n<figure class=\"gb-block-image gb-block-image-4fc14921\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4fc14921\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details1.webp\" alt=\"\" title=\"distribution-transformer-details1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details1-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-64cafa73\"><div class=\"gb-container gb-container-64cafa73\">\n\n<figure class=\"gb-block-image gb-block-image-c5762194\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-c5762194\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details2.webp\" alt=\"\" title=\"distribution-transformer-details2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details2-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b5f12304\"><div class=\"gb-container gb-container-b5f12304\">\n\n<figure class=\"gb-block-image gb-block-image-cf22cbbc\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-cf22cbbc\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details3.webp\" alt=\"\" title=\"distribution-transformer-details3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details3.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details3-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-84602a06\"><div class=\"gb-container gb-container-84602a06\">\n\n<figure class=\"gb-block-image gb-block-image-37efc46b\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-37efc46b\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details4.webp\" alt=\"\" title=\"distribution-transformer-details4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details4.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-details4-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ff98aefa\">\n<div class=\"gb-container gb-container-09841b9b\">\n<div class=\"gb-container gb-container-4df5c905\">\n\n<h2 class=\"gb-headline gb-headline-ef1fb936 gb-headline-text\">Transformer Shipment<\/h2>\n\n\n<div class=\"gb-container gb-container-bacb2a7a\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-7bf0f241\">\n<div class=\"gb-grid-column gb-grid-column-7839f0e5\"><div class=\"gb-container gb-container-7839f0e5\">\n\n<figure class=\"gb-block-image gb-block-image-385cff22\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-385cff22\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-shipment1.webp\" alt=\"\" title=\"distribution-transformer-shipment1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-shipment1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/distribution-transformer-shipment1-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-192e64a3\"><div class=\"gb-container gb-container-192e64a3\">\n\n<figure class=\"gb-block-image gb-block-image-f5d9b28c\"><img loading=\"lazy\" decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-f5d9b28c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1.webp\" alt=\"\" title=\"transformer-shipment1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1.webp 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-300x225.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-1024x768.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-768x576.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-1536x1152.webp 1536w\" sizes=\"auto, (max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d1225ce\"><div class=\"gb-container gb-container-6d1225ce\">\n\n<figure class=\"gb-block-image gb-block-image-c7e967d0\"><img loading=\"lazy\" decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-c7e967d0\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3.webp\" alt=\"\" title=\"transformer-shipment3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3.webp 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-300x225.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-1024x768.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-768x576.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-1536x1152.webp 1536w\" sizes=\"auto, (max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-c58b010c\"><div class=\"gb-container gb-container-c58b010c\">\n\n<figure class=\"gb-block-image gb-block-image-0a5acc3d\"><img loading=\"lazy\" decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-0a5acc3d\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4.webp\" alt=\"\" title=\"transformer-shipment4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4.webp 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-300x225.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-1024x768.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-768x576.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-1536x1152.webp 1536w\" sizes=\"auto, (max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-65aca6ce\">\n\n<a class=\"gb-button gb-button-a5a1d347 gb-button-text\" href=\"#popmake-573\">Contact Our Experts<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-78bd397f\">\n<div class=\"gb-container gb-container-a95c5231\">\n<div class=\"gb-container gb-container-c346eeb6\">\n\n<h2 class=\"gb-headline gb-headline-1ff1e64b gb-headline-text\">What Is a Distribution Transformer?<\/h2>\n\n\n<div class=\"gb-container gb-container-73504a68\">\n\n<p class=\"wp-block-paragraph\">A \u200bdistribution transformer\u200b (also called a power distribution transformer) is a critical component of electrical grids, stepping down high-voltage electricity from power stations to safer, usable low-voltage levels for end-users. Common applications include \u200b<strong>residential buildings, factories, and rural infrastructure<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tengyi Distribution Transformer Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Energy efficiency<\/li>\n\n\n\n<li>Custom for different demands<\/li>\n\n\n\n<li>Durability for industrial or harsh environments<\/li>\n<\/ul>\n\n<\/div>\n\n<div class=\"gb-container gb-container-e1079793\">\n\n<a class=\"gb-button gb-button-c2a0f11d gb-button-text\" href=\"#popmake-573\">Contact Our Experts<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-d433cd12\">\n<div class=\"gb-container gb-container-488fdd9d\">\n<div class=\"gb-container gb-container-56bc0b73\">\n\n<h2 class=\"gb-headline gb-headline-b8c809b4 gb-headline-text\">Types of Distribution Transformers: Choosing the Right One for Your Needs<\/h2>\n\n\n<div class=\"gb-container gb-container-c1ba0701\">\n\n<h3 class=\"wp-block-heading\">Dry Type Distribution Transformer\u200b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ideal for indoor installations such as hospitals, data centers, and urban areas where fire safety is critical. These transformers use no oil, reducing fire risks and maintenance requirements. Their energy-efficient design makes them suitable for environments like schools or office buildings.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bOverhead\/Pole Mounted Transformer\u200b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Perfect for rural areas, temporary setups, and cost-effective outdoor power distribution. Lightweight and easy to install, they are widely used in agricultural regions or rural infrastructure projects.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bPad Mounted &amp; Underground Transformers\u200b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Designed for urban infrastructure (parking lots, sidewalks) requiring flood resistance and noise reduction. Their compact, aesthetically pleasing design ensures they blend seamlessly into cityscapes while protecting against extreme weather conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bSpecialized Types\u200b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Submersible Transformer<\/strong>: Used in water-intensive environments like fish farms or mining operations to deliver power underwater.<\/li>\n\n\n\n<li>\u200b<strong>Three-Winding Transformer<\/strong>: Powers multiple voltage circuits simultaneously, making them ideal for industrial complexes requiring simultaneous low-, medium-, and high-voltage outputs.<\/li>\n\n\n\n<li>\u200b<strong>Amorphous Transformer<\/strong>: Reduces energy loss in high-load scenarios such as data centers or manufacturing plants, thanks to the non-crystalline core material.<\/li>\n<\/ul>\n\n<\/div>\n\n<div class=\"gb-container gb-container-c5e70671\">\n\n<a class=\"gb-button gb-button-3eaa3bb4 gb-button-text\" href=\"#popmake-573\">Customize Your Projects Now<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-1a8ff42b\">\n<div class=\"gb-container gb-container-60a12fe0\">\n<div class=\"gb-container gb-container-d12bdbe1\">\n\n<h2 class=\"gb-headline gb-headline-8b097efc gb-headline-text\">Distribution Transformer Specifications: Voltage, Capacity, and Phase<\/h2>\n\n\n<div class=\"gb-container gb-container-3f38c2a2\">\n\n<h3 class=\"wp-block-heading\">Voltage Ratings\u200b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Low Voltage (LV)<\/strong>: \u200b<strong>10kV\/0.433V distribution transformers<\/strong>\u200b are standard for residential and small commercial use, stepping down power for homes and light commercial buildings.<\/li>\n\n\n\n<li>\u200b<strong>Medium Voltage (MV)<\/strong>: \u200b<strong>33kV\/433V distribution transformers<\/strong>\u200b serve industrial facilities and power substations, efficiently managing medium-voltage power distribution.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bCapacity Range\u200b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Small Capacity (10\u201350 kVA)<\/strong>: Ideal for rural grids, single-phase residential areas, and small businesses requiring minimal power.<\/li>\n\n\n\n<li>\u200b<strong>Medium Capacity (100\u2013250 kVA)<\/strong>: Fits medium-sized commercial buildings like offices, hotels, and retail spaces.<\/li>\n\n\n\n<li>\u200b<strong>Large Capacity (315\u2013500 kVA)<\/strong>: Required for heavy industrial operations such as factories, hospitals, and data centers with continuous high-load demands.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bPhase Configuration\u200b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Three-Phase Transformer<\/strong>: Powers motors and equipment in industrial settings, ensuring stable operation for machinery.<\/li>\n\n\n\n<li>\u200b<strong>Single-Phase Transformer<\/strong>: Used in areas with predominantly single-phase loads, such as rural homes or temporary construction sites.<\/li>\n<\/ul>\n\n<\/div>\n\n<div class=\"gb-container gb-container-4f4f98bf\">\n\n<a class=\"gb-button gb-button-ca0d1676 gb-button-text\" href=\"#popmake-573\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-22afdc9d\">\n<div class=\"gb-container gb-container-ed42eb24\">\n<div class=\"gb-container gb-container-0c1e9394\">\n\n<h2 class=\"gb-headline gb-headline-9e284ed1 gb-headline-text\">How to Choose a Distribution Transformer?<\/h2>\n\n\n<div class=\"gb-container gb-container-eec94630\">\n\n<h3 class=\"wp-block-heading\">Consider Your Application\u200b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For \u200b<strong>residential buildings<\/strong>, prioritize \u200b<strong>low voltage distribution transformers<\/strong>\u200b (e.g., \u200b<strong>10kVA distribution transformers<\/strong>) with noise-reduction features.<\/li>\n\n\n\n<li>In \u200b<strong>industrial facilities<\/strong>, select \u200b<strong>high voltage distribution transformers<\/strong>\u200b and energy-efficient models like \u200b<strong>amorphous core transformers<\/strong>.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bAssess Energy Efficiency\u200b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Invest in \u200b<strong>energy efficient distribution transformers<\/strong>\u200b to reduce long-term operational costs, especially for high-load environments like data centers.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u200bMaintenance and Lifespan\u200b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Choose transformers with durable cores (<strong>distribution transformer core<\/strong>) and robust windings to minimize downtime and maintenance needs.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-edcda8de\">\n\n<a class=\"gb-button gb-button-a4de0723 gb-button-text\" href=\"#popmake-573\">Quote High Efficient Tansformer at Competitive Price<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-bd47d3b3\">\n<div class=\"gb-container gb-container-202a226e\">\n<div class=\"gb-container gb-container-cbd47874\">\n\n<h2 class=\"gb-headline gb-headline-59dcae65 gb-headline-text\">Detailed Distribution Transformer Guide: Voltage, Capacities, and Ideal Applications by Scenario<\/h2>\n\n\n<div class=\"gb-container gb-container-e90fa780\">\n\n<h3 class=\"wp-block-heading\"><strong>By Voltage Rating<\/strong><strong><\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>10kV Distribution Transformer<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Urban\/Rural Power Grids<\/strong>: Step down 10kV to 0.4kV\/0.22kV for residential areas, shops, and small factories.<\/li><\/ul><ul><li>\u200b<strong>Industrial Plants<\/strong>: Supply power to low-voltage equipment (e.g., pumps, lighting, HVAC systems).<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Agriculture<\/strong>: Irrigation systems, farm equipment, and rural substations.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Typical Capacities<\/strong>: 25kVA\u2013630kVA (depends on load density).<\/li>\n\n\n\n<li>\u200b<strong>Examples<\/strong>:<ul><li>\u200b<strong>25kVA 10kV\/0.4kV<\/strong>: Single-family homes, small clinics.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>315kVA 10kV\/0.4kV<\/strong>: Shopping malls, community centers, medium-sized workshops.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>11kV Distribution Transformer<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Industrial Parks<\/strong>: Power high-voltage motors (6kV\/10kV), electric furnaces, and compressors.<\/li><\/ul><ul><li>\u200b<strong>Commercial Complexes<\/strong>: Supply power to elevators, escalators, and large HVAC systems.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Mining\/Oil Fields<\/strong>: Underground machinery, oil extraction pumps, and drilling rigs.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Typical Capacities<\/strong>: 100kVA\u20132,500kVA (higher capacities for industrial use).<\/li>\n\n\n\n<li>\u200b<strong>Examples<\/strong>:<ul><li>\u200b<strong>100kVA 11kV\/0.4kV<\/strong>: Small processing plants, gas stations.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>250kVA 11kV\/0.4kV<\/strong>: Medium-sized manufacturing facilities, data center UPS systems.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>11kV 433V Distribution Transformer<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Specialized Industries<\/strong>: Equipment in Europe\/regions using 433V (e.g., motors, compressors).<\/li><\/ul><ul><li>\u200b<strong>Maritime\/Shipping<\/strong>: Shipboard power systems, port cranes, and offshore platforms.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Retrofit Projects<\/strong>: Upgrade legacy 433V systems in older urban areas.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Typical Capacities<\/strong>: 50kVA\u2013500kVA (match load requirements).<\/li>\n\n\n\n<li>\u200b<strong>Examples<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>200kVA 11kV\/433V<\/strong>: Chemical reactor motors, subway traction power systems.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>By Capacity<\/strong><strong><\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>25kVA\u201350kVA<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Residential<\/strong>: Single-family homes, villas, or apartment complexes.<\/li><\/ul><ul><li>\u200b<strong>Small Businesses<\/strong>: Hair salons, cafes, printing shops.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Agriculture<\/strong>: Greenhouse lighting, small water pumps.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Common Voltages<\/strong>: 10kV\/0.4kV or 380V\/0.22kV.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>50kVA\u2013100kVA<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Commercial Spaces<\/strong>: Stores, restaurants, supermarket refrigeration units.<\/li><\/ul><ul><li>\u200b<strong>Office Buildings<\/strong>: Floor power panels, emergency lighting.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Public Infrastructure<\/strong>: Streetlights, park billboards.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Common Voltage<\/strong>: 10kV\/0.4kV.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>100kVA\u2013250kVA<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Medium-Sized Factories<\/strong>: Production line motors, air compressors, packaging machines.<\/li><\/ul><ul><li>\u200b<strong>Hospitals\/Schools<\/strong>: Surgical rooms, classroom lighting, computer labs.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Data Centers<\/strong>: Server racks (requires UPS integration).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Common Voltages<\/strong>: 10kV\/0.4kV or 11kV\/0.4kV.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>250kVA\u2013630kVA<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Application Scenarios<\/strong>:<ul><li>\u200b<strong>Heavy Industry<\/strong>: Steel rolling mills, cement kilns, port gantry cranes.<\/li><\/ul><ul><li>\u200b<strong>Large Commercial Complexes<\/strong>: Shopping malls, hotel HVAC systems.<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Regional Substations<\/strong>: Power distribution hubs for multiple neighborhoods.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Common Voltage<\/strong>: 10kV\/0.4kV or 11kV\/0.4kV.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Key Selection Guidelines<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Voltage Matching<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>10kV<\/strong>: Ideal for end-of-line distribution in urban\/rural grids (wide coverage but higher losses).<\/li>\n\n\n\n<li><strong>11kV<\/strong>: Better for short-distance, high-power industrial applications (reduces voltage drop).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Capacity Calculation<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Formula<\/strong>:&nbsp;Transformer&nbsp;Capacity\u22653\u200b\u00d7Voltage&nbsp;(kV)Total&nbsp;Load&nbsp;(kW)\u200b\u00d71.2&nbsp;(safety margin).\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Example<\/strong>: For a 50kW three-phase load at 0.4kV:<br>1.732\u00d70.450,000\u200b\u224872<em>kV<\/em><em>A<\/em>\u2192Choose&nbsp;100<em>kVA<\/em>.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Environmental Considerations<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Oil-Immersed (ONAN)<\/strong>: Outdoor use (e.g., farms, roads).<\/li>\n\n\n\n<li><strong>Dry-Type (ODAF\/OFAF)<\/strong>: Indoor use (e.g., malls, hospitals) for fire safety.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Typical Use Cases<\/strong><strong><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u200b<\/strong><strong>Transformer Specification<\/strong><strong><\/strong><\/td><td><strong>\u200b<\/strong><strong>Application<\/strong><strong><\/strong><\/td><td><strong>\u200b<\/strong><strong>Load Type<\/strong><strong><\/strong><\/td><\/tr><tr><td>\u200b<strong>10kV\/0.4kV 315kVA<\/strong><\/td><td>Shopping mall<\/td><td>Central AC, store lighting, food prep<\/td><\/tr><tr><td>\u200b<strong>11kV\/0.4kV 250kVA<\/strong><\/td><td>Cement plant<\/td><td>Roller mill motors, dust collection<\/td><\/tr><tr><td>\u200b<strong>11kV\/433V 200kVA<\/strong><\/td><td>Chemical factory<\/td><td>Reactor motors, pump systems<\/td><\/tr><tr><td>\u200b<strong>10kV\/0.4kV 100kVA<\/strong><\/td><td>Community hospital<\/td><td>MRI machines, operating room lights<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-9297d5d4\">\n\n<a class=\"gb-button gb-button-0812f670 gb-button-text\" href=\"#popmake-573\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-c63ac2c5\">\n<div class=\"gb-container gb-container-1f3c7fd3\">\n<div class=\"gb-container gb-container-e023ff7b\">\n\n<h2 class=\"gb-headline gb-headline-bb8320a4 gb-headline-text\">\u200bApplications of Distribution Transformers<\/h2>\n\n\n<div class=\"gb-container gb-container-1a02e887\">\n\n<p class=\"wp-block-paragraph\"><strong>Residential Buildings<\/strong>\u200b rely on \u200b<strong>single-phase pad mounted transformers<\/strong>\u200b (10\u2013250 kVA) to deliver stable, low-voltage power while minimizing noise for comfort.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Commercial Complexes<\/strong>\u200b often use \u200b<strong>three-phase overhead transformers<\/strong>\u200b (100\u2013500 kVA) to support high-load operations like lighting systems and HVAC equipment, prioritizing energy efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Industrial Facilities<\/strong>\u200b require \u200b<strong>amorphous three-phase transformers<\/strong>\u200b (315\u2013500 kVA) to handle heavy machinery and power-intensive processes, with features like harmonic resistance and short-circuit withstand capability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Rural Infrastructure<\/strong>\u200b benefits from \u200b<strong>pole-mounted transformers<\/strong>\u200b (10\u201350 kVA) due to their cost-effectiveness and weather resistance, making them ideal for areas with limited access to maintenance services.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u200b<strong>Scenario\u200b<\/strong><\/td><td><strong>\u200bRecommended Transformer Type\u200b<\/strong><\/td><td><strong>\u200bKey Considerations\u200b<\/strong><\/td><\/tr><tr><td>\u200bResidential Buildings\u200b<\/td><td>Single-phase pad mounted transformers (10\u2013250 kVA)<\/td><td>Noise control, low voltage output<\/td><\/tr><tr><td>\u200bCommercial Complexes\u200b<\/td><td>Three-phase overhead transformers (100\u2013500 kVA)<\/td><td>High load capacity, energy efficiency<\/td><\/tr><tr><td>\u200bIndustrial Facilities\u200b<\/td><td>Amorphous three-phase transformers (315\u2013500 kVA)<\/td><td>Harmonic resistance, short-circuit withstand<\/td><\/tr><tr><td>\u200bRural Infrastructure\u200b<\/td><td>Pole-mounted transformers (10\u201350 kVA)<\/td><td>Cost-effectiveness, weather resistance<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ea6e05e6\">\n\n<a class=\"gb-button gb-button-33771e31 gb-button-text\" href=\"#popmake-573\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-c7ece3be\">\n<div class=\"gb-container gb-container-436fa27a\">\n<div class=\"gb-container gb-container-37f3fc63\">\n\n<h2 class=\"gb-headline gb-headline-68af1987 gb-headline-text\">What Is A Three Winding Distribution Transformer?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A \u200b<strong>three-winding transformer<\/strong>&nbsp;is a specialized power transformer featuring \u200b<strong>three independent windings<\/strong>&nbsp;(primary, secondary, and tertiary) designed for \u200b<strong>multi-voltage power systems<\/strong>&nbsp;or \u200b<strong>complex load distribution scenarios<\/strong>. Compared to traditional dual-winding transformers, it offers greater flexibility in power supply but comes with higher structural complexity and cost.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Core Structure and Working Principle<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u200bThree Independent Windings<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Each winding connects to different voltage levels (e.g., 110kV\/35kV\/10kV):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Primary winding<\/strong>: Inputs from the power grid or generator.<\/li>\n\n\n\n<li>\u200b<strong>Secondary winding<\/strong>: Outputs for medium-voltage loads.<\/li>\n\n\n\n<li>\u200b<strong>Tertiary winding<\/strong>: Supplies low-voltage equipment or isolated circuits.<br>Voltage ratios between windings depend on the \u200b<strong>turns ratio<\/strong>.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u200b<strong>Common Connection Methods<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Winding configurations use \u200b<strong>star (Y)<\/strong>&nbsp;or \u200b<strong>delta (\u0394)<\/strong>&nbsp;patterns, forming various \u200b<strong>connection groups<\/strong>&nbsp;(e.g., YNyn0, Yd11):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>YNyn0<\/strong>:\n<ul class=\"wp-block-list\">\n<li>High-voltage and low-voltage windings in star (Y) configuration.<\/li>\n\n\n\n<li>Neutral points directly grounded.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Yd11<\/strong>:\n<ul class=\"wp-block-list\">\n<li>High-voltage winding in star (Y), low-voltage in delta (\u0394).<\/li>\n\n\n\n<li>30\u00b0 phase shift between windings for harmonic suppression.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Main Application Scenarios<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Power System Hubs<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Power Plants<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Step up generator output (e.g., 10kV) to transmission voltages (e.g., 220kV\/500kV).<\/li>\n\n\n\n<li>Simultaneously power plant auxiliary equipment (e.g., lighting, control systems) at low voltage (e.g., 400V).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Regional Substations<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Interface between transmission (e.g., 220kV), distribution (e.g., 110kV), and local networks (e.g., 35kV).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Industrial Distribution<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Large Factories<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Supply high-voltage motors (e.g., 6kV) and low-voltage control systems (e.g., 380V).<\/li>\n\n\n\n<li>Isolate factory internal grids from external supplies.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Data Centers<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Provide multi-voltage backups (e.g., 400V\/230V) for redundancy.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u200bSpecialized Applications<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>Railway Systems<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Isolate traction power (e.g., 27.5kV) from station loads (e.g., 10kV).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u200b<strong>Offshore Platforms<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Integrate platform internal power (e.g., 440V) with land-based transmission (e.g., 110kV).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages and Challenges<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u200b<strong>Advantage<\/strong><\/th><th>\u200b<strong>Challenge<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u200b<strong>Multi-functional<\/strong>: Supports multiple voltage conversions and loads.<\/td><td>\u200b<strong>Complex Structure<\/strong>: Higher manufacturing costs due to multiple windings and core design.<\/td><\/tr><tr><td>\u200b<strong>High Reliability<\/strong>: Electrical isolation between windings prevents cascading failures.<\/td><td>\u200b<strong>Maintenance<\/strong>: Requires advanced protection systems (e.g., differential relays).<\/td><\/tr><tr><td>\u200b<strong>Energy Efficiency<\/strong>: Ideal for dense multi-voltage grids.<\/td><td>\u200b<strong>Lower Efficiency<\/strong>: Increased no-load losses due to inter-winding flux leakage.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-fc3e92ce\">\n\n<a class=\"gb-button gb-button-b9d7d6e2 gb-button-text\" href=\"#popmake-573\">Quote High Efficient Tansformer at Competitive Price<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-d4a417bf\">\n<div class=\"gb-container gb-container-b77d6870\">\n<div class=\"gb-container gb-container-1cb2db8d\">\n\n<h2 class=\"gb-headline gb-headline-a782f79a gb-headline-text\">Why Choose Tengyi?<\/h2>\n\n\n<div class=\"gb-container gb-container-4c75ae2a\">\n\n<p class=\"wp-block-paragraph\">At Tengyi, we provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200bCompetitive pricing.<\/li>\n\n\n\n<li>\u200bHigh-quality distribution transformers\u200b for all applications.<\/li>\n\n\n\n<li>\u200bTailor-made service. Request bespoke voltage, capacity, and phase configurations to meet unique project requirements.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Contact us today\u200b to request a \u200bdistribution transformer quote\u200b or learn more about our \u200bpower distribution transformer manufacturers!<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b389f44f\">\n<div class=\"gb-container gb-container-2c68dd12\">\n<div class=\"gb-container gb-container-702d50c7\">\n<div class=\"gb-container gb-container-1bdbd7d4\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4967a93a\">\n<div class=\"gb-grid-column gb-grid-column-3e0e599b\"><div class=\"gb-container gb-container-3e0e599b\">\n<div class=\"gb-container gb-container-1cf38dc2\">\n\n<h2 class=\"gb-headline gb-headline-81cda2cf gb-headline-text\">Quote Tengyi Transformer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5a5e7314\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Your main parameters of the transformer (voltage, capacity, loss and others)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-400a0365\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Your transformer operating environment (altitude, temperature, humidity, location, etc.)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-4a9dfbde\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Other customized requirements (tap changer, color, oil pillow, etc.)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5acd21ee\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Minimum order quantity: 1 unit<\/span><\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-1f62aadb\"><div class=\"gb-container gb-container-1f62aadb\">\n<div class=\"gb-container gb-container-fde8cba9\">\n<div class='fluentform ff-default fluentform_wrapper_3  ff_guten_block ff_guten_block-3 ffs_custom_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_custom\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u8868\u5355\u8be2\u76d8 &#8211; \u53d8\u538b\u5668<\/legend><input type='hidden' name='__fluent_form_embded_post_id' value='1008' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"b2ca7b3842\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/ru\/wp-json\/wp\/v2\/pages\/1008\" \/><div data-type=\"name-element\" data-name=\"names\" class=\" ff-field_container ff-name-field-wrapper\" ><div class='ff-t-container'><div class='ff-t-cell '><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_names_first_name_' id='label_ff_3_names_first_name_'>Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[first_name]\" id=\"ff_3_names_first_name_\" class=\"ff-el-form-control\" placeholder=\"Name*\" aria-invalid=\"false\" aria-required=true><\/div><\/div><\/div><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email'>Email<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"Email*\" data-name=\"email\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_phone' id='label_ff_3_phone'>Phone\/Mobile<\/label><\/div><div class='ff-el-input--content'><input name=\"phone\" class=\"ff-el-form-control ff-el-phone\" type=\"tel\" placeholder=\"Phone*\" data-name=\"phone\" id=\"ff_3_phone\" inputmode=\"tel\"  aria-invalid='false' aria-required=true><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_description' id='label_ff_3_description'>Textarea<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_3_description\" name=\"description\" id=\"ff_3_description\" class=\"ff-el-form-control\" rows=\"7\" cols=\"2\" data-name=\"description\" ><\/textarea><\/div><\/div><input type=\"hidden\" name=\"visitor_country\" value=\"unknown\" data-name=\"visitor_country\" ><input type=\"hidden\" name=\"created_at_beijing\" value=\"unknown\" data-name=\"created_at_beijing\" ><input type=\"hidden\" name=\"ai_verdict\" value=\"unknown\" data-name=\"ai_verdict\" ><input type=\"hidden\" name=\"ai_reason\" value=\"unknown\" data-name=\"ai_reason\" ><input type=\"hidden\" name=\"ai_elapsed_ms\" value=\"unknown\" data-name=\"ai_elapsed_ms\" ><input type=\"hidden\" name=\"ai_provider\" value=\"unknown\" data-name=\"ai_provider\" ><input type=\"hidden\" name=\"ai_model\" value=\"unknown\" data-name=\"ai_model\" ><input type=\"hidden\" name=\"ads_eligible\" value=\"unknown\" data-name=\"ads_eligible\" ><input type=\"hidden\" name=\"ads_source\" value=\"unknown\" data-name=\"ads_source\" ><input type=\"hidden\" name=\"gclid\" value=\"unknown\" data-name=\"gclid\" ><input type=\"hidden\" name=\"gbraid\" value=\"unknown\" data-name=\"gbraid\" ><input type=\"hidden\" name=\"wbraid\" value=\"unknown\" data-name=\"wbraid\" ><input type=\"hidden\" name=\"utm_source\" value=\"unknown\" data-name=\"utm_source\" ><input type=\"hidden\" name=\"utm_medium\" value=\"unknown\" data-name=\"utm_medium\" ><input type=\"hidden\" name=\"utm_campaign\" value=\"unknown\" data-name=\"utm_campaign\" ><input type=\"hidden\" name=\"utm_term\" value=\"unknown\" data-name=\"utm_term\" ><input type=\"hidden\" name=\"utm_content\" value=\"unknown\" data-name=\"utm_content\" ><input type=\"hidden\" name=\"landing_page\" value=\"unknown\" data-name=\"landing_page\" ><input type=\"hidden\" name=\"referrer\" value=\"unknown\" data-name=\"referrer\" ><div class='ff-form-inline-style' hidden><style>form.fluent_form_3 .ff-btn-submit:not(.ff_btn_no_style) { background-color: var(--fluentform-primary); color: #ffffff; }<\/style><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Get A Free Quote\">Get A Free Quote<\/button><\/div><\/fieldset><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"asteriskPlacement\":\"asterisk-right\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"names[first_name]\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"names[middle_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"names[last_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global_message\":\"This field must contain a valid email\",\"global\":true}},\"phone\":{\"required\":{\"value\":true,\"global\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\"},\"valid_phone_number\":{\"value\":false,\"global\":true,\"message\":\"Phone number is not valid\",\"global_message\":\"Phone number is not valid\"}},\"description\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>\n            \n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b: \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u043c \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u043f\u043e\u0434 \u0437\u0430\u043a\u0430\u0437 \u0441 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u043c\u0438 \u0443\u0440\u043e\u0432\u043d\u044f\u043c\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c \u0438 \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u043c \u0443\u0441\u043b\u0443\u0433\u0438 OEM. \u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 Tengyi: \u0420\u0430\u0437\u044a\u0435\u043c\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 10 \u043a\u0412 \u0438 1600 \u043a\u0412\u0410. \u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c: ... <\/p>\n<p class=\"read-more-container\"><a title=\"\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/ru\/distribution-transformer\/#more-1008\" aria-label=\"\u041f\u0440\u043e\u0447\u0438\u0442\u0430\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0435 \u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0435\">\u0427\u0438\u0442\u0430\u0439\u0442\u0435 \u0434\u0430\u043b\u044c\u0448\u0435<\/a><\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1008","page","type-page","status-publish","no-featured-image-padding"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Distribution Transformer For Sale - Consistent Power Distribution<\/title>\n<meta name=\"description\" content=\"High-efficiency distribution transformers for residential, commercial, &amp; industrial needs. Durable, long-lasting, and cost-effective. Quote.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tengyielectric.com\/ru\/\u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439-\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Distribution Transformer For Sale - Consistent Power Distribution\" \/>\n<meta property=\"og:description\" content=\"High-efficiency distribution transformers for residential, commercial, &amp; industrial needs. Durable, long-lasting, and cost-effective. Quote.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tengyielectric.com\/ru\/\u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439-\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:26:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data1\" content=\"15 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/\",\"name\":\"Distribution Transformer For Sale - Consistent Power Distribution\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/s11-distribution-transformer.webp\",\"datePublished\":\"2025-01-24T08:38:59+00:00\",\"dateModified\":\"2026-10-29T06:26:57+00:00\",\"description\":\"High-efficiency distribution transformers for residential, commercial, & industrial needs. Durable, long-lasting, and cost-effective. Quote.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/s11-distribution-transformer.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/s11-distribution-transformer.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/distribution-transformer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Distribution Transformer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0432 \u043f\u0440\u043e\u0434\u0430\u0436\u0435 \u2014 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438","description":"\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u0431\u044b\u0442\u043e\u0432\u044b\u0445, \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043d\u0443\u0436\u0434. \u041f\u0440\u043e\u0447\u043d\u044b\u0435, \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u044b\u0435 \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u044b\u0433\u043e\u0434\u043d\u044b\u0435. \u0417\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u044c \u0446\u0435\u043d\u043e\u0432\u043e\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0435.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tengyielectric.com\/ru\/\u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439-\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\/","og_locale":"ru_RU","og_type":"article","og_title":"Distribution Transformer For Sale - Consistent Power Distribution","og_description":"High-efficiency distribution transformers for residential, commercial, & industrial needs. Durable, long-lasting, and cost-effective. Quote.","og_url":"https:\/\/tengyielectric.com\/ru\/\u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439-\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\/","og_site_name":"Tengyi Electric","article_modified_time":"2026-10-29T06:26:57+00:00","og_image":[{"url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"15 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/tengyielectric.com\/distribution-transformer\/","url":"https:\/\/tengyielectric.com\/distribution-transformer\/","name":"\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0432 \u043f\u0440\u043e\u0434\u0430\u0436\u0435 \u2014 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tengyielectric.com\/distribution-transformer\/#primaryimage"},"image":{"@id":"https:\/\/tengyielectric.com\/distribution-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp","datePublished":"2025-01-24T08:38:59+00:00","dateModified":"2026-10-29T06:26:57+00:00","description":"\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u0431\u044b\u0442\u043e\u0432\u044b\u0445, \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043d\u0443\u0436\u0434. \u041f\u0440\u043e\u0447\u043d\u044b\u0435, \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u044b\u0435 \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u044b\u0433\u043e\u0434\u043d\u044b\u0435. \u0417\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u044c \u0446\u0435\u043d\u043e\u0432\u043e\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0435.","breadcrumb":{"@id":"https:\/\/tengyielectric.com\/distribution-transformer\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tengyielectric.com\/distribution-transformer\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/tengyielectric.com\/distribution-transformer\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/s11-distribution-transformer.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/tengyielectric.com\/distribution-transformer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Distribution Transformer"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u00ab\u0422\u044d\u043d\u044a\u0438\u00bb","description":"\u0412\u0435\u0434\u0443\u0449\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u043d\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u00ab\u0422\u044d\u043d\u044a\u0438\u00bb","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/pages\/1008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/comments?post=1008"}],"version-history":[{"count":2,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/pages\/1008\/revisions"}],"predecessor-version":[{"id":2680,"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/pages\/1008\/revisions\/2680"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/ru\/wp-json\/wp\/v2\/media?parent=1008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}