{"id":1811,"date":"2025-12-19T14:11:49","date_gmt":"2025-12-19T06:11:49","guid":{"rendered":"https:\/\/tengyielectric.com\/?p=1811"},"modified":"2025-12-22T16:48:13","modified_gmt":"2025-12-22T08:48:13","slug":"livraison-de-transformateurs-monophases-aux-philippines","status":"publish","type":"post","link":"https:\/\/tengyielectric.com\/fr\/single-phase-transformers-delivery-to-the-philippines\/","title":{"rendered":"Livraison de transformateurs monophas\u00e9s aux Philippines"},"content":{"rendered":"<div class=\"gb-container gb-container-3e46977c\">\n<div class=\"gb-container gb-container-07fbd4be\">\n<div class=\"gb-container gb-container-dbe22cd8\">\n\n<h2 class=\"gb-headline gb-headline-15dcb0ac gb-headline-text\"><strong><strong><strong><strong>Livraison de transformateurs monophas\u00e9s dans un conteneur complet de 40 pieds aux Philippines<\/strong><\/strong><\/strong><\/strong><\/h2>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9ba03615\">\n<div class=\"gb-container gb-container-d8e45bca\">\n<div class=\"gb-container gb-container-06e5aada\">\n\n<p class=\"wp-block-paragraph\">Aujourd\u2019hui, nous avons charg\u00e9 et exp\u00e9di\u00e9 avec succ\u00e8s un&nbsp;<strong>conteneur complet de 40 pieds \u00e0 hauteur accrue (High Cube) de transformateurs monophas\u00e9s sur poteau<\/strong> \u00e0 destination des Philippines.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Aper\u00e7u du produit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu\u2019un important distributeur \u00e9lectrique aux Philippines\u2014une entreprise comptant plus de 30 ans d\u2019exp\u00e9rience dans la vente en gros et au d\u00e9tail de transformateurs\u2014a d\u00fb r\u00e9approvisionner ses stocks pour r\u00e9pondre \u00e0 des besoins urgents du r\u00e9seau local, elle s\u2019est tourn\u00e9e vers son partenaire de confiance : Tengyi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forte d\u2019une longue collaboration fructueuse, la cliente exigeait un chargement complet de conteneur (FCL) de transformateurs sur poteau personnalis\u00e9s et haute performance, livr\u00e9s avec pr\u00e9cision et une stricte conformit\u00e9 aux normes internationales.<\/p>\n\n\n<div class=\"gb-container gb-container-4a6116f7\">\n<div class=\"gb-container gb-container-2569392e\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-0967f1e1\">\n<div class=\"gb-grid-column gb-grid-column-fed1e284\"><div class=\"gb-container gb-container-fed1e284\">\n\n<figure class=\"gb-block-image gb-block-image-51d6c419\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-51d6c419\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3.webp\" alt=\"\" title=\"38 transformateurs monophas\u00e9s aux Philippines3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines3-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-27b58bf8\"><div class=\"gb-container gb-container-27b58bf8\">\n\n<figure class=\"gb-block-image gb-block-image-cac36d86\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-cac36d86\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1.webp\" alt=\"\" title=\"38 transformateurs monophas\u00e9s aux Philippines1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines1-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f2c1613a\"><div class=\"gb-container gb-container-f2c1613a\">\n\n<figure class=\"gb-block-image gb-block-image-c4785edf\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"1000\" class=\"gb-image gb-image-c4785edf\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2.webp\" alt=\"\" title=\"38 transformateurs monophas\u00e9s aux Philippines2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2.webp 850w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-255x300.webp 255w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-768x904.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/38-single-phase-transformers-to-the-philippines2-10x12.webp 10w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Solution Tengyi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tengyi a mis \u00e0 profit son expertise industrielle pour fournir une solution cl\u00e9 en main adapt\u00e9e aux sp\u00e9cifications exactes du client.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ing\u00e9nierie de pr\u00e9cision<\/strong><br>Nous avons fabriqu\u00e9&nbsp;<strong>38 unit\u00e9s de transformateurs monophas\u00e9s sur poteau de 50 kVA<\/strong>&nbsp;(mod\u00e8le D-50\/13.2). Les principales caract\u00e9ristiques techniques \u00e9taient les suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Rapport de tension :<\/strong>\u00a0Haute tension 13 200 Y \/ 7 620 V vers basse tension 120 \/ 240 V.<\/li>\n\n\n\n<li><strong>Mat\u00e9riau de l'enroulement :<\/strong>\u00a0Cuivre de haute qualit\u00e9 (CU\/CU) pour une conductivit\u00e9 et une durabilit\u00e9 sup\u00e9rieures.<\/li>\n\n\n\n<li><strong>Refroidissement :<\/strong>\u00a0Type ONAN (huile naturelle \/ air naturel), avec huile min\u00e9rale, con\u00e7u pour une \u00e9l\u00e9vation de temp\u00e9rature de 65 \u00b0C.<\/li>\n\n\n\n<li><strong>La s\u00e9curit\u00e9 :<\/strong>\u00a0\u00c9quip\u00e9 de soupapes de d\u00e9charge de pression et de travers\u00e9es haute tension adapt\u00e9es \u00e0 une installation s\u00e9curis\u00e9e sur poteau.<\/li>\n<\/ul>\n\n\n<div class=\"gb-container gb-container-3985f2cb\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-306f50ff\">\n<div class=\"gb-grid-column gb-grid-column-68fb26c3\"><div class=\"gb-container gb-container-68fb26c3\">\n\n<figure class=\"gb-block-image gb-block-image-4cb23278\"><img loading=\"lazy\" decoding=\"async\" width=\"1140\" height=\"810\" class=\"gb-image gb-image-4cb23278\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2.webp\" alt=\"\" title=\"Transformateurs monophas\u00e9s mont\u00e9s sur poteau aux Philippines \u2013 conception2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2.webp 1140w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-300x213.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-1024x728.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-768x546.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design2-18x12.webp 18w\" sizes=\"auto, (max-width: 1140px) 100vw, 1140px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-525a89c3\"><div class=\"gb-container gb-container-525a89c3\">\n\n<figure class=\"gb-block-image gb-block-image-a3b67144\"><img loading=\"lazy\" decoding=\"async\" width=\"1140\" height=\"810\" class=\"gb-image gb-image-a3b67144\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1.webp\" alt=\"\" title=\"Transformateurs monophas\u00e9s mont\u00e9s sur poteau aux Philippines \u2013 conception1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1.webp 1140w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-300x213.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-1024x728.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-768x546.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-pole-mounted-transformers-in-philippines-design1-18x12.webp 18w\" sizes=\"auto, (max-width: 1140px) 100vw, 1140px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Assurance qualit\u00e9<\/strong><br>Avant exp\u00e9dition, chaque unit\u00e9 a subi des essais rigoureux dans nos installations, notamment la mesure de l\u2019imp\u00e9dance (\u00e0 85 \u00b0C), des pertes en charge et des pertes \u00e0 vide, garantissant ainsi le respect par chaque transformateur des normes d\u2019efficacit\u00e9 exig\u00e9es par le client.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">En coulisses : production et savoir-faire<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Comme le montrent nos images de production, chaque unit\u00e9 de cette commande a fait l\u2019objet d\u2019un processus de fabrication m\u00e9ticuleux. De l\u2019enroulement pr\u00e9cis des bobines \u00e0 l\u2019assemblage du circuit magn\u00e9tique et au remplissage final du r\u00e9servoir, notre \u00e9quipe a veill\u00e9 \u00e0 ce que chaque d\u00e9tail r\u00e9ponde aux exigences sp\u00e9cifiques de tension et d\u2019efficacit\u00e9 du r\u00e9seau philippin.<\/p>\n\n\n<div class=\"gb-container gb-container-914221ed\">\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Transformateur Tengyi mont\u00e9 sur poteau \u2013 De la production aux essais avant livraison\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/-v8OE7XILHk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Essais rigoureux : la r\u00e9f\u00e9rence de l\u2019excellence<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Avant que toute unit\u00e9 ne quitte notre usine, elle doit faire la preuve de sa valeur. Pour cette commande aux Philippines, nous avons effectu\u00e9 sur chaque transformateur le test routinier 100%.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tel que captur\u00e9 dans notre laboratoire d\u2019essais :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pr\u00e9cision num\u00e9rique :<\/strong>&nbsp;Nous avons utilis\u00e9 des analyseurs de puissance avanc\u00e9s pour v\u00e9rifier le rapport, la polarit\u00e9 et l\u2019angle de phase.<\/li>\n\n\n\n<li><strong>V\u00e9rification des performances :<\/strong>&nbsp;Les pertes en charge et les pertes \u00e0 vide ont \u00e9t\u00e9 mesur\u00e9es rigoureusement afin de garantir l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique.<\/li>\n\n\n\n<li><strong>Assurance de la s\u00e9curit\u00e9 :<\/strong>&nbsp;Des essais de tenue en tension \u00e9lev\u00e9e ont \u00e9t\u00e9 r\u00e9alis\u00e9s pour garantir la s\u00e9curit\u00e9 op\u00e9rationnelle sur site.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Seulement apr\u00e8s avoir pass\u00e9 ces essais rigoureux, les unit\u00e9s ont \u00e9t\u00e9 approuv\u00e9es pour l\u2019emballage.<\/p>\n\n\n<div class=\"gb-container gb-container-d1dc6f35\">\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Essai du transformateur monophas\u00e9 mont\u00e9 sur poteau Tengyi\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/9cDyBP8TUks?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-292aeac9\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-518a1e52\">\n<div class=\"gb-grid-column gb-grid-column-cdcc536c\"><div class=\"gb-container gb-container-cdcc536c\">\n\n<h3 class=\"wp-block-heading\">Logistique s\u00e9curis\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Afin de garantir que les transformateurs arrivent \u00e0 Manille dans un \u00e9tat impeccable, nous avons utilis\u00e9 des syst\u00e8mes de caissons en bois renforc\u00e9s, optimis\u00e9s pour le chargement en conteneur. Comme le montrent les photos d\u2019exp\u00e9dition, les unit\u00e9s sont empil\u00e9es de fa\u00e7on s\u00e9curis\u00e9e \u00e0 l\u2019int\u00e9rieur du conteneur 40HQ, maximisant l\u2019espace tout en assurant la stabilit\u00e9 pendant le transport maritime.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Confiance mondiale, engagement local<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Que nous accueillions de nouveaux partenaires pour des visites d\u2019usine ou que nous exp\u00e9diions des conteneurs entiers \u00e0 des professionnels chevronn\u00e9s aux Philippines, Tengyi reste r\u00e9solument engag\u00e9e \u00e0 alimenter le monde avec des solutions \u00e9lectriques sup\u00e9rieures.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f2d5875f\"><div class=\"gb-container gb-container-f2d5875f\">\n<div class=\"gb-container gb-container-97dbf4e6\">\n\n<figure class=\"gb-block-image gb-block-image-af7cab49\"><img loading=\"lazy\" decoding=\"async\" width=\"998\" height=\"979\" class=\"gb-image gb-image-af7cab49\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp\" alt=\"\" title=\"Transformateurs monophas\u00e9s aux Philippines\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp 998w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-300x294.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-768x753.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines-12x12.webp 12w\" sizes=\"auto, (max-width: 998px) 100vw, 998px\" \/><\/figure>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b884af38\">\n<div class=\"gb-container gb-container-0d997913\">\n<div class=\"gb-container gb-container-12d6c45c\">\n<div class=\"gb-container gb-container-e4b92954\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-c263af85\">\n<div class=\"gb-grid-column gb-grid-column-be74dc72\"><div class=\"gb-container gb-container-be74dc72\">\n\n<p class=\"gb-headline gb-headline-a01f4858 gb-headline-text\">Contactez nos experts pour obtenir le meilleur prix usine<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nos solutions transformateurs sont con\u00e7ues pour s\u2019adapter pr\u00e9cis\u00e9ment \u00e0 votre fr\u00e9quence r\u00e9seau et \u00e0 vos normes de tension. En vous associant \u00e0 Tengyi, vous b\u00e9n\u00e9ficiez de solutions comprenant une durabilit\u00e9 sup\u00e9rieure des enroulements en cuivre, une conformit\u00e9 stricte aux normes IEEE et une r\u00e9duction significative des co\u00fbts totaux d\u2019importation gr\u00e2ce \u00e0 un chargement intelligent des conteneurs.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-3726250d\"><div class=\"gb-container gb-container-3726250d\">\n<div class=\"gb-container gb-container-4f0d8dd7\">\n\n<a class=\"gb-button gb-button-7d9b861c gb-button-text\" href=\"#popmake-561\">Obtenir un devis gratuit<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Livraison compl\u00e8te d\u2019un conteneur de 40 pieds de transformateurs monophas\u00e9s aux Philippines \u2013 Aujourd\u2019hui, nous avons charg\u00e9 et exp\u00e9di\u00e9 avec succ\u00e8s un conteneur High Cube de 40 pieds enti\u00e8rement rempli de transformateurs monophas\u00e9s sur poteau destin\u00e9s aux Philippines. \u2013 Aper\u00e7u du produit : Lorsqu\u2019un important distributeur \u00e9lectrique\u2026 <\/p>\n<p class=\"read-more-container\"><a title=\"Livraison de transformateurs monophas\u00e9s aux Philippines\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/fr\/single-phase-transformers-delivery-to-the-philippines\/#more-1811\" aria-label=\"En savoir plus sur la livraison de transformateurs \u00e0 phase unique aux Philippines\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":1813,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cases","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Single Phase Transformers Delivery to the Philippines - Tengyi Electric<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single Phase Transformers Delivery to the Philippines - Tengyi Electric\" \/>\n<meta property=\"og:description\" content=\"Full 40-Foot Container Single Phase Transformers Delivery to the Philippines Today, we successfully loaded and shipped a&nbsp;full 40ft High Cube Container&nbsp;of Single-Phase Pole Mounted Transformers destined for the&nbsp;Philippines. Product Overview When a leading electrical distributor ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-19T06:11:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-22T08:48:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.png\" \/>\n\t<meta property=\"og:image:width\" content=\"998\" \/>\n\t<meta property=\"og:image:height\" content=\"979\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"TYElectric\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"TYElectric\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"},\"author\":{\"name\":\"TYElectric\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\"},\"headline\":\"Single Phase Transformers Delivery to the Philippines\",\"datePublished\":\"2025-12-19T06:11:49+00:00\",\"dateModified\":\"2025-12-22T08:48:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"},\"wordCount\":523,\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"articleSection\":[\"Cases\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\",\"name\":\"Single Phase Transformers Delivery to the Philippines - Tengyi Electric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"datePublished\":\"2025-12-19T06:11:49+00:00\",\"dateModified\":\"2025-12-22T08:48:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/single-phase-transformers-to-philippines.webp\",\"width\":998,\"height\":979},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/single-phase-transformers-delivery-to-the-philippines\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single Phase Transformers Delivery to the Philippines\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\",\"name\":\"TYElectric\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"caption\":\"TYElectric\"},\"url\":\"https:\\\/\\\/tengyielectric.com\\\/fr\\\/author\\\/tyelectric\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Livraison de transformateurs monophas\u00e9s aux Philippines \u2013 Tengyi Electric","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","og_locale":"fr_FR","og_type":"article","og_title":"Single Phase Transformers Delivery to the Philippines - Tengyi Electric","og_description":"Full 40-Foot Container Single Phase Transformers Delivery to the Philippines Today, we successfully loaded and shipped a&nbsp;full 40ft High Cube Container&nbsp;of Single-Phase Pole Mounted Transformers destined for the&nbsp;Philippines. Product Overview When a leading electrical distributor ... Lire plus","og_url":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","og_site_name":"Tengyi Electric","article_published_time":"2025-12-19T06:11:49+00:00","article_modified_time":"2025-12-22T08:48:13+00:00","og_image":[{"width":998,"height":979,"url":"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.png","type":"image\/png"}],"author":"TYElectric","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"TYElectric","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#article","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"},"author":{"name":"TYElectric","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896"},"headline":"Single Phase Transformers Delivery to the Philippines","datePublished":"2025-12-19T06:11:49+00:00","dateModified":"2025-12-22T08:48:13+00:00","mainEntityOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"},"wordCount":523,"publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","articleSection":["Cases"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/","name":"Livraison de transformateurs monophas\u00e9s aux Philippines \u2013 Tengyi Electric","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","datePublished":"2025-12-19T06:11:49+00:00","dateModified":"2025-12-22T08:48:13+00:00","breadcrumb":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/12\/single-phase-transformers-to-philippines.webp","width":998,"height":979},{"@type":"BreadcrumbList","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/single-phase-transformers-delivery-to-the-philippines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Single Phase Transformers Delivery to the Philippines"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"Tengyi Electric","description":"Fabricant leader de transformateurs","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"Tengyi Electric","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896","name":"TYElectric","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","caption":"TYElectric"},"url":"https:\/\/tengyielectric.com\/fr\/author\/tyelectric\/"}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/posts\/1811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/comments?post=1811"}],"version-history":[{"count":0,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/posts\/1811\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/media\/1813"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/media?parent=1811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/categories?post=1811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tengyielectric.com\/fr\/wp-json\/wp\/v2\/tags?post=1811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}