{"id":855,"date":"2025-01-09T14:09:41","date_gmt":"2025-01-09T06:09:41","guid":{"rendered":"https:\/\/s3jnrqxbrg.onrocket.site\/?page_id=855"},"modified":"2026-08-28T17:56:08","modified_gmt":"2026-08-28T09:56:08","slug":"transformador-de-potencia","status":"publish","type":"page","link":"https:\/\/tengyielectric.com\/es\/power-transformer\/","title":{"rendered":"Transformador de potencia"},"content":{"rendered":"<div class=\"gb-container gb-container-f2d0df70\">\n<div class=\"gb-container gb-container-87b37709\">\n<div class=\"gb-container gb-container-f70d84af\">\n\n<h1 class=\"gb-headline gb-headline-c3ead352 gb-headline-text\">Power Transformer<\/h1>\n\n\n\n<p class=\"gb-headline gb-headline-1c44214b gb-headline-text\">Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9bedf81d\">\n<div class=\"gb-container gb-container-e46be8ee\">\n<div class=\"gb-container gb-container-b23703f4\">\n<div class=\"gb-container gb-container-66b9cb03\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-eaf06577\">\n<div class=\"gb-grid-column gb-grid-column-93eece37\"><div class=\"gb-container gb-container-93eece37\">\n<div class=\"gb-container gb-container-f69fb4aa\">\n\n\t\t<!-- MasterSlider -->\n\t\t<div id=\"P_MS6ae8f7b435cc8\" class=\"master-slider-parent msl ms-parent-id-4\" style=\"max-width:800px;\">\n\n\t\t\t\n\t\t\t<!-- MasterSlider Main -->\n\t\t\t<div id=\"MS6ae8f7b435cc8\" class=\"master-slider ms-skin-default\" >\n\t\t\t\t \t\t\t\t \n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-sale.png\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-sale-140x80.png\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail7.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail7-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail1.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail1-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail2.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail2-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail3.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail3-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail4.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail4-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail5.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail5-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail6.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail6-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail8.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail8-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\n\t\t\t<\/div>\n\t\t\t<!-- END MasterSlider Main -->\n\n\t\t\t \n\t\t<\/div>\n\t\t<!-- END MasterSlider -->\n\n\t\t<script>\n\t\t(function ( $ ) {\n\t\t\t\"use strict\";\n\n\t\t\t$(function () {\n\t\t\t\tvar masterslider_5cc8 = new MasterSlider();\n\n\t\t\t\t\/\/ slider controls\n\t\t\t\tmasterslider_5cc8.control('arrows'     ,{ autohide:false, overVideo:true  });\t\t\t\tmasterslider_5cc8.control('bullets'    ,{ autohide:false, overVideo:true, dir:'h', align:'bottom' , margin:10  });\n\n\t\t\t\tmasterslider_5cc8.control('thumblist'  ,{ autohide:false, overVideo:true, dir:'h', speed:17, inset:false, arrows:false, hover:false, customClass:'', align:'bottom',type:'thumbs', margin:5, width:140, height:80, space:5, fillMode:'fill'  });\n\t\t\t\t\/\/ slider setup\n\t\t\t\tmasterslider_5cc8.setup(\"MS6ae8f7b435cc8\", {\n\t\t\t\t\t\twidth           : 650,\n\t\t\t\t\t\theight          : 630,\n\t\t\t\t\t\tminHeight       : 0,\n\t\t\t\t\t\tspace           : 0,\n\t\t\t\t\t\tstart           : 1,\n\t\t\t\t\t\tgrabCursor      : true,\n\t\t\t\t\t\tswipe           : true,\n\t\t\t\t\t\tmouse           : true,\n\t\t\t\t\t\tlayout          : \"boxed\",\n\t\t\t\t\t\twheel           : false,\n\t\t\t\t\t\tautoplay        : true,\n\t\t\t\t\t\tinstantStartLayers:false,\n\t\t\t\t\t\tloop            : true,\n\t\t\t\t\t\tshuffle         : false,\n\t\t\t\t\t\tpreload         : 0,\n\t\t\t\t\t\theightLimit     : true,\n\t\t\t\t\t\tautoHeight      : false,\n\t\t\t\t\t\tsmoothHeight    : true,\n\t\t\t\t\t\tendPause        : false,\n\t\t\t\t\t\toverPause       : true,\n\t\t\t\t\t\tfillMode        : \"fill\",\n\t\t\t\t\t\tcenterControls  : true,\n\t\t\t\t\t\tstartOnAppear   : false,\n\t\t\t\t\t\tlayersMode      : \"center\",\n\t\t\t\t\t\thideLayers      : false,\n\t\t\t\t\t\tfullscreenMargin: 0,\n\t\t\t\t\t\tspeed           : 20,\n\t\t\t\t\t\tdir             : \"h\",\n\t\t\t\t\t\tparallaxMode    : 'swipe',\n\t\t\t\t\t\tview            : \"basic\"\n\t\t\t\t});\n\n\t\t\t\t\n\t\t\t\twindow.masterslider_instances = window.masterslider_instances || [];\n\t\t\t\twindow.masterslider_instances.push( masterslider_5cc8 );\n\t\t\t });\n\n\t\t})(jQuery);\n\t\t<\/script>\n\n\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb3dfde6\"><div class=\"gb-container gb-container-eb3dfde6\">\n<div class=\"gb-container gb-container-4e1a0988\">\n\n<h2 class=\"gb-headline gb-headline-7258d199 gb-headline-text\">Power Transformer For Sale<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-2e34a941 gb-headline-text\">Tengyi power transformer is reliable, efficient, and designed for optimal performance. Ideal for power plants, substations, large factories, and petrochemical enterprises. Ensures reliable performance for industrial and grid applications.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d8ebb883 gb-headline-text\">Main Parameters<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-27ca91ab\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Power rating:<\/strong> 6.3-240MVA<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-012f0c5f\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Primary voltage: <\/strong>66kV; 110kV; 220kV; Customize<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be479e67\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>Secondary voltage: <\/strong>6.3kV-69kV; Customize<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-838d3be8 gb-headline-text\">Working Conditions<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-cca7f3b7\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Altitude should not exceed 1000 meters.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9a54171d\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Operating environment temperature should be between -25\u2103 and +40\u2103.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-05779465\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The relative humidity should not exceed 90%(+25\u2103).<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-56dd8c24\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The vertical inclination does not exceed 5\u00b0.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-0bacef22\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">The outdoor wind speed does not exceed 35m\/s.<\/span><\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-bf2c2659\">\n\n<a class=\"gb-button gb-button-67c92043 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-92e0c466\">\n<div class=\"gb-container gb-container-018f91a0\">\n<div class=\"gb-container gb-container-d0d4194c\">\n\n<h2 class=\"gb-headline gb-headline-72c1a7bd gb-headline-text\">Tengyi Power Transformer Advantages<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-333d9159 gb-headline-text\">Tengyi main power transformer provides efficient voltage transformation, ensuring reliable power distribution across various applications. Its robust design enhances durability and minimizes maintenance needs. Additionally, the transformer is engineered for high performance, safety, and energy efficiency, making it suitable for both urban and industrial settings.<\/p>\n\n\n<div class=\"gb-container gb-container-8645fb41\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-096ad6d8\">\n<div class=\"gb-grid-column gb-grid-column-a5ad70ad\"><div class=\"gb-container gb-container-a5ad70ad\">\n<div class=\"gb-container gb-container-394eaaa3 box-shadow\">\n<div class=\"gb-container gb-container-107c6b9e\">\n\n<h3 class=\"gb-headline gb-headline-c8d655c4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>Low Noise Levels<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-e9b2e4ab gb-headline-text\">Minimizes environmental noise pollution, ensuring quieter operation in urban and residential areas. This feature enhances community acceptance and reduces noise-related disturbances.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb4ce9ec\"><div class=\"gb-container gb-container-eb4ce9ec\">\n<div class=\"gb-container gb-container-369e45f4 box-shadow\">\n<div class=\"gb-container gb-container-825a954d\">\n\n<h3 class=\"gb-headline gb-headline-8f6f5716\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>Low Temperature Rise<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-a6ec4c2c gb-headline-text\">Offers strong overload capacity, maintaining efficient operation even under high demand. This feature helps in preventing overheating and extending the transformer&#8217;s service life.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-848ab375\"><div class=\"gb-container gb-container-848ab375\">\n<div class=\"gb-container gb-container-2b0a1ce0 box-shadow\">\n<div class=\"gb-container gb-container-d9a5bba3\">\n\n<h3 class=\"gb-headline gb-headline-2d8a461e\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>Low Energy Loss<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-866cce29 gb-headline-text\">Optimizes energy structure by reducing power loss, leading to improved efficiency and cost savings. This contributes to a more sustainable and economical power distribution system.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-28d68822\"><div class=\"gb-container gb-container-28d68822\">\n<div class=\"gb-container gb-container-c184f74c box-shadow\">\n<div class=\"gb-container gb-container-8d33aa0c\">\n\n<h3 class=\"gb-headline gb-headline-3e36ab2b\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>Minimal Partial Discharge<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-703d9ad4 gb-headline-text\">Ensures stable and reliable operation by reducing electrical stress, which prolongs transformer lifespan and enhances performance under various load conditions.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d4594f3\"><div class=\"gb-container gb-container-6d4594f3\">\n<div class=\"gb-container gb-container-86db63c4 box-shadow\">\n<div class=\"gb-container gb-container-9d0a8965\">\n\n<h3 class=\"gb-headline gb-headline-40be9ad4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>No Leakage Design<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-d30e367f gb-headline-text\">Tengyi power transformer provides high sealing performance, preventing oil or coolant leaks. This ensures environmental safety and reduces the risk of contamination, maintaining operational integrity.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f6923e84\"><div class=\"gb-container gb-container-f6923e84\">\n<div class=\"gb-container gb-container-d33107a7 box-shadow\">\n<div class=\"gb-container gb-container-eb8fa6f4\">\n\n<h3 class=\"gb-headline gb-headline-42815d27\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewBox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>Maintenance-Free Operation<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-1ef1ca4a gb-headline-text\">Reduces customer maintenance costs by eliminating the need for frequent servicing. This advantage ensures consistent performance and reliability with minimal intervention.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f9e68e6b\">\n\n<a class=\"gb-button gb-button-ef0351a3 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-6fcd151c\">\n<div class=\"gb-container gb-container-6e3ddcdc\">\n<div class=\"gb-container gb-container-8dc4b63d\">\n\n<h2 class=\"gb-headline gb-headline-acf3b302 gb-headline-text\">110kV, 25000kVA Power Transformer Design<\/h2>\n\n\n\n<figure class=\"gb-block-image gb-block-image-e03afde8\"><img loading=\"lazy\" decoding=\"async\" width=\"2456\" height=\"1686\" class=\"gb-image gb-image-e03afde8\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp\" alt=\"\" title=\"110kv-power-transformer-design\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp 2456w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-300x206.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-1024x703.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-768x527.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-1536x1054.webp 1536w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-2048x1406.webp 2048w\" sizes=\"auto, (max-width: 2456px) 100vw, 2456px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-3c2e491a\">\n\n<h3 class=\"gb-headline gb-headline-a31cd1ee gb-headline-text\">Three Phase Duplex Winding Power Transformer On-Load Changer Specification<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Rated Capacity(kVA)<\/td><td colspan=\"2\">Voltage Combined<\/td><td rowspan=\"2\">Vector Group<\/td><td rowspan=\"2\">No-Load Loss(kw)<\/td><td rowspan=\"2\">75\u2103 Load Loss\uff08kw1)<\/td><td rowspan=\"2\">No Load Current(%)<\/td><td rowspan=\"2\">Short-Circuit Impendance(%)<\/td><\/tr><tr><td>HV(kV)<\/td><td>LV(kV)<\/td><\/tr><tr><td>6300<\/td><td rowspan=\"11\">110\u00b18*1.25%<\/td><td rowspan=\"11\">6.3<br>6.6<br>10.5<br>11<\/td><td rowspan=\"11\">YNd11<\/td><td>10<\/td><td>36<\/td><td>0.8<\/td><td rowspan=\"11\">10.5<\/td><\/tr><tr><td>8000<\/td><td>12<\/td><td>45<\/td><td>0.8<\/td><\/tr><tr><td>10000<\/td><td>14.2<\/td><td>53<\/td><td>0.74<\/td><\/tr><tr><td>12500<\/td><td>16.8<\/td><td>63<\/td><td>0.74<\/td><\/tr><tr><td>16000<\/td><td>20.2<\/td><td>77<\/td><td>0.69<\/td><\/tr><tr><td>20000<\/td><td>24<\/td><td>93<\/td><td>0.69<\/td><\/tr><tr><td>25000<\/td><td>28.4<\/td><td>110<\/td><td>0.64<\/td><\/tr><tr><td>31500<\/td><td>33.8<\/td><td>133<\/td><td>0.64<\/td><\/tr><tr><td>40000<\/td><td>40.4<\/td><td>156<\/td><td>0.58<\/td><\/tr><tr><td>50000<\/td><td>47.8<\/td><td>194<\/td><td>0.58<\/td><\/tr><tr><td>63000<\/td><td>56.8<\/td><td>234<\/td><td>0.52<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-140ded7c\">\n\n<a class=\"gb-button gb-button-09555e88 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-5e2f8db3\">\n\n<h3 class=\"gb-headline gb-headline-0a1cceb9 gb-headline-text\">Three Phase Three Winding Power Transformer On-Load Changer Specification<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Rated Capacity(kVA)<\/td><td colspan=\"3\">Voltage Combined<\/td><td rowspan=\"2\">Vector Group<\/td><td rowspan=\"2\">No-Load Loss(kw)<\/td><td rowspan=\"2\">75\u2103 Load Loss\uff08kw1)<\/td><td rowspan=\"2\">No Load Current(%)<\/td><td rowspan=\"2\">Short-Circuit Impendance(%)<\/td><\/tr><tr><td>HV(kV)<\/td><td>MV(kV)<\/td><td>LV(kV)<\/td><\/tr><tr><td>6300<\/td><td rowspan=\"11\">110\u00b18*1.25%<\/td><td rowspan=\"11\">35<br>37<br>38.5<\/td><td rowspan=\"11\">6.3<br>6.6<br>10.5<br>11<\/td><td rowspan=\"11\">YNyn0d11<\/td><td>12<\/td><td>47<\/td><td>0.95<\/td><td rowspan=\"11\">10.5<br>17.5-18.5<br>6.5<\/td><\/tr><tr><td>8000<\/td><td>14.4<\/td><td>56<\/td><td>0.95<\/td><\/tr><tr><td>10000<\/td><td>17.1<\/td><td>66<\/td><td>0.89<\/td><\/tr><tr><td>12500<\/td><td>20.2<\/td><td>78<\/td><td>0.89<\/td><\/tr><tr><td>16000<\/td><td>24.2<\/td><td>95<\/td><td>0.84<\/td><\/tr><tr><td>20000<\/td><td>28.6<\/td><td>112<\/td><td>0.84<\/td><\/tr><tr><td>25000<\/td><td>33.8<\/td><td>133<\/td><td>0.78<\/td><\/tr><tr><td>31500<\/td><td>40.2<\/td><td>157<\/td><td>0.78<\/td><\/tr><tr><td>40000<\/td><td>48.2<\/td><td>189<\/td><td>0.73<\/td><\/tr><tr><td>50000<\/td><td>56.9<\/td><td>225<\/td><td>0.73<\/td><\/tr><tr><td>63000<\/td><td>67.7<\/td><td>270<\/td><td>0.67<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-6420c3b8\">\n\n<a class=\"gb-button gb-button-c10e0170 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9f4b17f0\">\n\n<h3 class=\"gb-headline gb-headline-a06e7ecf gb-headline-text\">Three Phase Three Winding Non-Field Excitation Changer Self Coupling Power Transformer Specification<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Rated Capacity(kVA)<\/td><td colspan=\"3\">Voltage Combined<\/td><td rowspan=\"2\">Vector Group<\/td><td colspan=\"3\">Step up Combination<\/td><td colspan=\"3\">Step down Combination<\/td><td colspan=\"2\">Short-Circuit Impendance(%)<\/td><\/tr><tr><td>HV(kV)<\/td><td>MV(kV)<\/td><td>LV(kV)<\/td><td>No Load Loss(kw)<\/td><td>Load Loss(kw)<\/td><td>No Load Current(%)<\/td><td>No Load Loss(kw)<\/td><td>Load Loss(kw)<\/td><td>No Load Current(%)<\/td><td>Step-up<\/td><td>Step-down<\/td><\/tr><tr><td>31500<\/td><td rowspan=\"9\">220\u00b12*2.5%<br><br>242\u00b12*2.5%<\/td><td rowspan=\"9\">115<br>121<\/td><td rowspan=\"5\">6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">YNa0d11<\/td><td>25<\/td><td>117<\/td><td>0.57<\/td><td>22<\/td><td>99<\/td><td>0.5<\/td><td rowspan=\"9\">12-14<br>8-12<br>14-18<\/td><td rowspan=\"9\">8-10<br>28-34<br>18-24<\/td><\/tr><tr><td>40000<\/td><td>29<\/td><td>144<\/td><td>0.57<\/td><td>26<\/td><td>121<\/td><td>0.5<\/td><\/tr><tr><td>50000<\/td><td>34<\/td><td>170<\/td><td>0.5<\/td><td>30<\/td><td>144<\/td><td>0.43<\/td><\/tr><tr><td>63000<\/td><td>40<\/td><td>201<\/td><td>0.5<\/td><td>36<\/td><td>171<\/td><td>0.43<\/td><\/tr><tr><td>90000<\/td><td>50<\/td><td>276<\/td><td>0.43<\/td><td>46<\/td><td>234<\/td><td>0.36<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"4\">10.5<br>11<br>13.8<br>15.75<br>18<br>35<br>37<br>38.5<\/td><td>62<\/td><td>340<\/td><td>0.43<\/td><td>56<\/td><td>288<\/td><td>0.6<\/td><\/tr><tr><td>150000<\/td><td>73<\/td><td>405<\/td><td>0.36<\/td><td>66<\/td><td>342<\/td><td>0.33<\/td><\/tr><tr><td>180000<\/td><td>84<\/td><td>463<\/td><td>0.36<\/td><td>76<\/td><td>387<\/td><td>0.33<\/td><\/tr><tr><td>240000<\/td><td>99<\/td><td>595<\/td><td>0.33<\/td><td>89<\/td><td>504<\/td><td>0.25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-890e4cf9\">\n\n<a class=\"gb-button gb-button-bb8393dd gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b3be7210\">\n\n<h3 class=\"gb-headline gb-headline-db8254d3 gb-headline-text\">Three Phase Duplex Winding Power Transformer On-Load Changer Specification<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Rated Capacity(kVA)<\/td><td colspan=\"2\">Voltage Combined<\/td><td rowspan=\"2\">Vector Group<\/td><td rowspan=\"2\">No-Load Loss(kw)<\/td><td rowspan=\"2\">75\u2103 Load Loss\uff08kw1)<\/td><td rowspan=\"2\">No Load Current(%)<\/td><td rowspan=\"2\">Short-Circuit Impendance(%)<\/td><\/tr><tr><td>HV(kV)<\/td><td>LV(kV)<\/td><\/tr><tr><td>31500<\/td><td rowspan=\"11\">220\u00b18*1.25%<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"11\">YNa0d11<\/td><td>38<\/td><td>135<\/td><td>0.7<\/td><td rowspan=\"11\">12-14<\/td><\/tr><tr><td>40000<\/td><td>45<\/td><td>157<\/td><td>0.63<\/td><\/tr><tr><td>50000<\/td><td>54<\/td><td>189<\/td><td>0.56<\/td><\/tr><tr><td>63000<\/td><td>63<\/td><td>220<\/td><td>0.56<\/td><\/tr><tr><td>90000<\/td><td>80<\/td><td>288<\/td><td>0.49<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"3\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>99<\/td><td>346<\/td><td>0.49<\/td><\/tr><tr><td>150000<\/td><td>116<\/td><td>405<\/td><td>0.42<\/td><\/tr><tr><td>180000<\/td><td>135<\/td><td>468<\/td><td>0.42<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"3\">66<br>69<\/td><td>102<\/td><td>355<\/td><td>0.49<\/td><\/tr><tr><td>150000<\/td><td>120<\/td><td>415<\/td><td>0.42<\/td><\/tr><tr><td>180000<\/td><td>140<\/td><td>475<\/td><td>0.42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-78b00c6a\">\n\n<a class=\"gb-button gb-button-d6a84abd gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-adb0fa00\">\n\n<h3 class=\"gb-headline gb-headline-2e79366d gb-headline-text\">Three Phase Three Winding Power Transformer Specification<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"10\"><strong>Three Phase Three Winding Power Transformer On-Load Changer<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Rated Capacity(kVA)<\/td><td colspan=\"3\">Voltage Combined<\/td><td rowspan=\"2\">Vector Group<\/td><td rowspan=\"2\">No-Load Loss(kw)<\/td><td rowspan=\"2\">75\u2103 Load Loss\uff08kw1)<\/td><td rowspan=\"2\">No Load Current(%)<\/td><td rowspan=\"2\">Capacity Assignment(%)<\/td><td rowspan=\"2\">Short-Circuit Impendance(%)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HV(kV)<\/td><td>MV(kV)<\/td><td>LV(kV)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">31500<\/td><td rowspan=\"9\">220\u00b18*1.25%<\/td><td rowspan=\"9\">69<br>115<br>121<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">YNyn0d11<\/td><td>44<\/td><td>162<\/td><td>0.77<\/td><td rowspan=\"9\">100\/100\/100<br>100\/50\/100<br>100\/100\/50<\/td><td rowspan=\"9\">12-14<br>22-24<br>7-9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40000<\/td><td>52<\/td><td>189<\/td><td>0.7<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">50000<\/td><td>60<\/td><td>225<\/td><td>0.63<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">63000<\/td><td>70<\/td><td>261<\/td><td>0.63<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">90000<\/td><td>92<\/td><td>351<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">120000<\/td><td rowspan=\"4\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>115<\/td><td>432<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150000<\/td><td>135<\/td><td>513<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">180000<\/td><td>156<\/td><td>630<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">240000<\/td><td>193<\/td><td>780<\/td><td>0.45<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"10\"><strong>Three Phase Three Winding On-Load Changer Word Coupling Power Transformer<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">31500<\/td><td rowspan=\"9\">220\u00b18*1.25%<\/td><td rowspan=\"9\">115<br>121<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">YNa0d11<\/td><td>25<\/td><td>108<\/td><td>0.56<\/td><td rowspan=\"9\">100\/100\/50<\/td><td rowspan=\"9\">8-10<br>28-34<br>18-24<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40000<\/td><td>30<\/td><td>132<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">50000<\/td><td>36<\/td><td>157<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">63000<\/td><td>42<\/td><td>189<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">90000<\/td><td>51<\/td><td>247<\/td><td>0.42<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">120000<\/td><td rowspan=\"4\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>64<\/td><td>307<\/td><td>0.42<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150000<\/td><td>76<\/td><td>365<\/td><td>0.35<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">180000<\/td><td>85<\/td><td>419<\/td><td>0.35<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">240000<\/td><td>104<\/td><td>540<\/td><td>0.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-ffefec8e\">\n\n<a class=\"gb-button gb-button-b8b7c3a7 gb-button-text\" href=\"#popmake-571\">Get A Free Quote<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fbd03688\">\n<div class=\"gb-container gb-container-bffb56fe\">\n<div class=\"gb-container gb-container-a99e2155\">\n<div class=\"gb-container gb-container-3f80dc29\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-90995f9e\">\n<div class=\"gb-grid-column gb-grid-column-73686e68\"><div class=\"gb-container gb-container-73686e68\">\n<div class=\"gb-container gb-container-3eb15824\">\n\n<figure class=\"wp-block-video\"><video height=\"480\" style=\"aspect-ratio: 854 \/ 480;\" width=\"854\" controls loop src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/tengyi-factory.mp4\"><\/video><\/figure>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-e7736112\"><div class=\"gb-container gb-container-e7736112\">\n<div class=\"gb-container gb-container-d01331a5\">\n\n<h2 class=\"gb-headline gb-headline-874b23bf gb-headline-text\">About Tengyi<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-95857e0e gb-headline-text\">We are a premier enterprise specialising in designing, manufacturing, and testing a wide array of transformers.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-f932b516 gb-headline-text\">Our advanced production facility covers over 11,000 square meters and features a maximum lifting capacity of 240 tons, allowing us to achieve an impressive annual production capacity of 12,000 MVA.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be10ada1 gb-headline-text\">We provide transformers suitable for voltage ranges from 52 to 800 kV, with power ratings from 20 to 600 MVA, and our auto-transformers can reach capacities of up to 1,000 MVA.<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-913a2618\">\n<div class=\"gb-container gb-container-c07f55d1\">\n<div class=\"gb-container gb-container-19b2a14c\">\n\n<h2 class=\"gb-headline gb-headline-1d8d4371 gb-headline-text\">Global Cases<\/h2>\n\n\n<div class=\"gb-container gb-container-f0d18b76\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-32068263\">\n<div class=\"gb-grid-column gb-grid-column-d02320c4\"><div class=\"gb-container gb-container-d02320c4 box-shadow\">\n<div class=\"gb-container gb-container-ab68bf74\">\n<div class=\"gb-container gb-container-329a9ed8\">\n\n<figure class=\"gb-block-image gb-block-image-39bb2b80\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-39bb2b80\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1.webp\" alt=\"\" title=\"power-transformer-case1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-82a9cc92\">\n\n<p class=\"gb-headline gb-headline-729c47f9 gb-headline-text\"><strong>Power Transformer Operation in Armenia<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-baca2751\"><div class=\"gb-container gb-container-baca2751 box-shadow\">\n<div class=\"gb-container gb-container-a8e4d95e\">\n<div class=\"gb-container gb-container-c0726d3f\">\n\n<figure class=\"gb-block-image gb-block-image-44b79544\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-44b79544\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2.webp\" alt=\"\" title=\"power-transformer-case2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-43279b81\">\n\n<p class=\"gb-headline gb-headline-c3c25117 gb-headline-text\"><strong>P<strong>ower<\/strong> Transformer On-Site Test in El Salvador <\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-bff5b29f\"><div class=\"gb-container gb-container-bff5b29f box-shadow\">\n<div class=\"gb-container gb-container-541133f5\">\n<div class=\"gb-container gb-container-1ef20011\">\n\n<figure class=\"gb-block-image gb-block-image-a7dc3dc9\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-a7dc3dc9\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3.webp\" alt=\"\" title=\"power-transformer-case3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ed484a3e\">\n\n<p class=\"gb-headline gb-headline-7281e1d0 gb-headline-text\"><strong>P<strong>ower<\/strong> Transformer Operation in Senegal<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6e595bbc\"><div class=\"gb-container gb-container-6e595bbc box-shadow\">\n<div class=\"gb-container gb-container-4912e1f2\">\n<div class=\"gb-container gb-container-960382d9\">\n\n<figure class=\"gb-block-image gb-block-image-cc71d6ef\"><img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-cc71d6ef\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4.webp\" alt=\"\" title=\"power-transformer-case4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4.webp 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4-252x300.webp 252w\" sizes=\"auto, (max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-f3443024\">\n\n<p class=\"gb-headline gb-headline-baa41fd6 gb-headline-text\"><strong>P<strong>ower<\/strong> Transformer Installation in Singapore<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-16798f9e\">\n\n<a class=\"gb-button gb-button-7d49b614 gb-button-text\" href=\"#popmake-573\">Customize Your Projects<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9b106039\">\n<div class=\"gb-container gb-container-222eb79e\">\n<div class=\"gb-container gb-container-c267a5c3\">\n\n<h2 class=\"gb-headline gb-headline-269e49db gb-headline-text\">Customer Feedback<\/h2>\n\n\n<div class=\"gb-container gb-container-598617b6\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-a1cf8e8f\">\n<div class=\"gb-grid-column gb-grid-column-0876043a\"><div class=\"gb-container gb-container-0876043a box-shadow\">\n<div class=\"gb-container gb-container-cb854a33\">\n\n<p class=\"gb-headline gb-headline-a7e17eaa gb-headline-text\"><strong>ATAROUWAIZOUNDINE<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&#8211; from Togo<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d5d293e6 gb-headline-text\">Tengyi&#8217;s transformers have greatly reduced our energy losses. The low temperature rise and robust design ensure reliability, even during peak loads. We&#8217;re very satisfied with their quality and efficiency.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9408837f gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-defb5ca7\"><div class=\"gb-container gb-container-defb5ca7 box-shadow\">\n<div class=\"gb-container gb-container-f5ea4cf7\">\n\n<p class=\"gb-headline gb-headline-635a1ae5 gb-headline-text\"><strong>OLABODE TOSIN<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&#8211; from Nigeria<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-39aca2b2 gb-headline-text\">The high voltage transformers we buy from Tengyi have proven to be incredibly durable. Even in harsh conditions, they maintain performance and show no signs of wear, which is crucial for our operations.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d438266a gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b31aff1d\">\n<div class=\"gb-container gb-container-0ff21d27\">\n<div class=\"gb-container gb-container-9ff863bf\">\n\n<h2 class=\"gb-headline gb-headline-166863e7 gb-headline-text\">Power Transformer Shell Production<\/h2>\n\n\n<div class=\"gb-container gb-container-92c8f335\">\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Power Transformer Shell Production\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/VIW_-iXfZxw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-93bd4d7a\">\n\n<a class=\"gb-button gb-button-268bab37 gb-button-text\" href=\"#popmake-573\">Customize Your Projects<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-a7c9826f\">\n<div class=\"gb-container gb-container-2d15f96e\">\n<div class=\"gb-container gb-container-b509a5ca\">\n\n<h2 class=\"gb-headline gb-headline-af18f263 gb-headline-text\">Power Transformer Workshop<\/h2>\n\n\n<div class=\"gb-container gb-container-afb8e67c\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-ec04d4c9\">\n<div class=\"gb-grid-column gb-grid-column-16bc3c39\"><div class=\"gb-container gb-container-16bc3c39\">\n\n<figure class=\"gb-block-image gb-block-image-4c25ac61\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4c25ac61\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1.webp\" alt=\"\" title=\"power-transformer-workshop1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-cdac3a5c\"><div class=\"gb-container gb-container-cdac3a5c\">\n\n<figure class=\"gb-block-image gb-block-image-d1d511b7\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-d1d511b7\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2.webp\" alt=\"\" title=\"power-transformer-workshop2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-83b1f304\"><div class=\"gb-container gb-container-83b1f304\">\n\n<figure class=\"gb-block-image gb-block-image-9595ad8a\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-9595ad8a\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3.webp\" alt=\"\" title=\"power-transformer-workshop3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-0f93ff24\"><div class=\"gb-container gb-container-0f93ff24\">\n\n<figure class=\"gb-block-image gb-block-image-4f95db6c\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4f95db6c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4.webp\" alt=\"\" title=\"power-transformer-workshop4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b5b41c7b\">\n<div class=\"gb-container gb-container-07e5685b\">\n<div class=\"gb-container gb-container-b4e2f617\">\n\n<h2 class=\"gb-headline gb-headline-db58d5b7 gb-headline-text\">Transformer Production Details<\/h2>\n\n\n<div class=\"gb-container gb-container-0320fa24\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-3e7d62cb\">\n<div class=\"gb-grid-column gb-grid-column-68e263cc\"><div class=\"gb-container gb-container-68e263cc\">\n\n<figure class=\"gb-block-image gb-block-image-4fc14921\"><img loading=\"lazy\" decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-4fc14921\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1.webp\" alt=\"\" title=\"transformer-production-details1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1.webp 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-300x225.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-1024x768.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-768x576.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-1536x1152.webp 1536w\" sizes=\"auto, (max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-64cafa73\"><div class=\"gb-container gb-container-64cafa73\">\n\n<figure class=\"gb-block-image gb-block-image-c5762194\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-c5762194\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2.webp\" alt=\"\" title=\"power transformer production details2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b5f12304\"><div class=\"gb-container gb-container-b5f12304\">\n\n<figure class=\"gb-block-image gb-block-image-cf22cbbc\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-cf22cbbc\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1.webp\" alt=\"\" title=\"power-transformer-production-details1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1-300x223.webp 300w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-84602a06\"><div class=\"gb-container gb-container-84602a06\">\n\n<figure class=\"gb-block-image gb-block-image-37efc46b\"><img loading=\"lazy\" decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-37efc46b\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4.webp\" alt=\"\" title=\"transformer-production-details4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4.webp 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-300x225.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-1024x768.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-768x576.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-1536x1152.webp 1536w\" sizes=\"auto, (max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ff98aefa\">\n<div class=\"gb-container gb-container-09841b9b\">\n<div class=\"gb-container gb-container-4df5c905\">\n\n<h2 class=\"gb-headline gb-headline-ef1fb936 gb-headline-text\">Transformer Shipment<\/h2>\n\n\n<div class=\"gb-container gb-container-bacb2a7a\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-7bf0f241\">\n<div class=\"gb-grid-column gb-grid-column-192e64a3\"><div class=\"gb-container gb-container-192e64a3\">\n\n<figure class=\"gb-block-image gb-block-image-f5d9b28c\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-f5d9b28c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery1.webp\" alt=\"\" title=\"power-transformer-delivery1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery1-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery1-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d1225ce\"><div class=\"gb-container gb-container-6d1225ce\">\n\n<figure class=\"gb-block-image gb-block-image-c7e967d0\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-c7e967d0\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery2.webp\" alt=\"\" title=\"power-transformer-delivery2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery2-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-delivery2-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-c58b010c\"><div class=\"gb-container gb-container-c58b010c\">\n\n<figure class=\"gb-block-image gb-block-image-0a5acc3d\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-0a5acc3d\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment4.webp\" alt=\"\" title=\"power-transformer-shipment4\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment4.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment4-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment4-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6756d306\"><div class=\"gb-container gb-container-6756d306\">\n\n<figure class=\"gb-block-image gb-block-image-6bc3f633\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-6bc3f633\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment1.webp\" alt=\"\" title=\"power-transformer-shipment1\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment1.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment1-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment1-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-694afce2\"><div class=\"gb-container gb-container-694afce2\">\n\n<figure class=\"gb-block-image gb-block-image-54a30cd8\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-54a30cd8\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment2.webp\" alt=\"\" title=\"power-transformer-shipment2\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment2.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment2-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment2-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-77ff004f\"><div class=\"gb-container gb-container-77ff004f\">\n\n<figure class=\"gb-block-image gb-block-image-bc14afe1\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-bc14afe1\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment3.webp\" alt=\"\" title=\"power-transformer-shipment3\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment3.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment3-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment3-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-21b2c071\"><div class=\"gb-container gb-container-21b2c071\">\n\n<figure class=\"gb-block-image gb-block-image-27add25a\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-27add25a\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment5.webp\" alt=\"\" title=\"power-transformer-shipment5\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment5.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment5-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment5-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-4a2faf54\"><div class=\"gb-container gb-container-4a2faf54\">\n\n<figure class=\"gb-block-image gb-block-image-716bf9ca\"><img loading=\"lazy\" decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-716bf9ca\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment6.webp\" alt=\"\" title=\"power-transformer-shipment6\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment6.webp 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment6-300x223.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/07\/power-transformer-shipment6-16x12.webp 16w\" sizes=\"auto, (max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-90cdd9d3\">\n<div class=\"gb-container gb-container-5d804c55\">\n<div class=\"gb-container gb-container-b4ecb024\">\n\n<h2 class=\"gb-headline gb-headline-2cbe547e gb-headline-text\">Components<\/h2>\n\n\n<div class=\"gb-container gb-container-8eaadcb8\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-46ed5465\">\n<div class=\"gb-grid-column gb-grid-column-18dc6766\"><div class=\"gb-container gb-container-18dc6766\">\n\n<figure class=\"gb-block-image gb-block-image-d25ab0e0\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-d25ab0e0\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core.webp\" alt=\"\" title=\"core\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core.webp 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core-255x300.webp 255w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-bcfbbbb6\"><div class=\"gb-container gb-container-bcfbbbb6\">\n\n<h3 class=\"gb-headline gb-headline-03831c9f gb-headline-text\">Core<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tengyi core uses <strong>high-quality, grain-oriented cold-rolled silicon steel sheets with high magnetic conductivity<\/strong>. Advanced automated shearing technology ensures burrs on the cut edges are less than 0.02 mm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A unique non-overlapping yoke design is employed, with silicon steel sheets joined using a 45-degree full-slope stepped joint. After stacking, the core (three columns and two yokes) is compressed and bonded with epoxy resin, creating a rigid, flat assembly with high vertical accuracy. This improves no-load performance and reduces noise.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Support plates secure the core columns against the inner windings. The yokes are tightened with epoxy resin-impregnated fiberglass tape, and the lower yoke is firmly held against the lower oil tank section by counter-pressure bolts. The upper yoke is additionally secured to the upper oil tank section at three points, ensuring the transformer core remains stable and immovable within the tank during transportation.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fd34f3cb\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-636a974e\">\n<div class=\"gb-grid-column gb-grid-column-164aa8db\"><div class=\"gb-container gb-container-164aa8db\">\n\n<figure class=\"gb-block-image gb-block-image-a62dd677\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-a62dd677\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding.webp\" alt=\"\" title=\"winding\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding.webp 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding-255x300.webp 255w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-1c24590a\"><div class=\"gb-container gb-container-1c24590a\">\n\n<h3 class=\"gb-headline gb-headline-f9a16617 gb-headline-text\">Windings<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tengyi&#8217;s high-voltage windings utilize a stranded, continuous structure to optimize voltage distribution under surge conditions, resulting in a more uniform electric field. Rounded edges on support structures and spacers further enhance insulation reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A winding internal design incorporates a meandering oil duct structure to ensure thorough cooling throughout the windings, minimizing temperature rise, reducing hot spots, and extending insulation life.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Separate tap windings are provided for high-voltage and medium-voltage regulation, balancing the ampere-turns in each winding. This effectively reduces axial electromagnetic forces during short circuits, improving the transformer&#8217;s ability to withstand sudden short-circuit events. The windings employ a &#8220;zero-margin&#8221; radial design. Thorough drying and precise fitting are implemented between the core and low-voltage winding, between the low-voltage, high-voltage, and tap windings, and between the support structures and surrounding components. This guarantees exceptional winding compactness and concentricity.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-63f0b4ed\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-0840434b\">\n<div class=\"gb-grid-column gb-grid-column-bafa936a\"><div class=\"gb-container gb-container-bafa936a\">\n\n<figure class=\"gb-block-image gb-block-image-11c49a78\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-11c49a78\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank.webp\" alt=\"\" title=\"oil-tank\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank.webp 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank-255x300.webp 255w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6522b706\"><div class=\"gb-container gb-container-6522b706\">\n\n<h3 class=\"gb-headline gb-headline-4fe49ec8 gb-headline-text\">Oil Tank<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The oil storage tank from Tengyi is constructed from a wide, single-piece steel sheet, formed into a corrugated structure. This eliminates welds, increasing mechanical strength and providing a dissipative effect that reduces noise. The secondary circuit wiring channels and control cabinet are made of stainless steel for a clean, aesthetically pleasing design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All sealing surfaces are precisely machined and utilize high-quality sealing materials. The tank top features a double-sealed groove, with the outer seal protecting the inner seal from atmospheric elements and UV radiation, maximizing seal lifespan and reliability.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-20bfcb6f\">\n\n<h3 class=\"gb-headline gb-headline-871dc461 gb-headline-text\">Other Components<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bushings:<\/strong>&nbsp;These are insulators that allow the high-voltage leads to pass safely through the tank wall without risking arcing or short circuits. They&#8217;re designed to withstand high voltages and provide reliable electrical insulation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Insulation System:<\/strong>&nbsp;It prevents electrical flashovers (arcs of electricity) and short circuits between the windings and the core, or between the windings themselves. This system is comprised of multiple layers including solid insulation (e.g., paper, pressboard) and liquid insulation (e.g., transformer oil). The oil also serves to cool the transformer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tap Changer:<\/strong>&nbsp;This is an optional component, but a very common one in high-voltage transformers. It allows for adjustments to the output voltage to maintain a stable voltage level, even if the input voltage or load varies. It&#8217;s typically located on the secondary winding and can be adjusted while the transformer is energized (under load tap changing) or de-energized.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cooling System:<\/strong>&nbsp;High-voltage transformers generate significant heat, so effective cooling is essential. This can involve oil circulation, air cooling, or even water cooling, depending on the size and power rating of the transformer. The cooling system is crucial for maintaining safe operating temperatures and preventing damage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These components work together to efficiently and safely transform high-voltage electricity to the desired voltage level for distribution or use. The precise design and materials used will vary depending on the specific application and power requirements of the transformer.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-cd9f29d2\">\n\n<a class=\"gb-button gb-button-fddd53b9 gb-button-text\" href=\"#popmake-573\">Talk to Our Experts Now<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b389f44f\">\n<div class=\"gb-container gb-container-2c68dd12\">\n<div class=\"gb-container gb-container-702d50c7\">\n<div class=\"gb-container gb-container-1bdbd7d4\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4967a93a\">\n<div class=\"gb-grid-column gb-grid-column-3e0e599b\"><div class=\"gb-container gb-container-3e0e599b\">\n<div class=\"gb-container gb-container-1cf38dc2\">\n\n<h2 class=\"gb-headline gb-headline-81cda2cf gb-headline-text\">Quote Tengyi Transformer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5a5e7314\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Your main parameters of the transformer (voltage, capacity, loss and others)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-400a0365\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Your transformer operating environment (altitude, temperature, humidity, location, etc.)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-4a9dfbde\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Other customized requirements (tap changer, color, oil pillow, etc.)?<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5acd21ee\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">Minimum order quantity: 1 unit<\/span><\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-1f62aadb\"><div class=\"gb-container gb-container-1f62aadb\">\n<div class=\"gb-container gb-container-fde8cba9\">\n<div class='fluentform ff-default fluentform_wrapper_3  ff_guten_block ff_guten_block-3 ffs_custom_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_custom\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u8868\u5355\u8be2\u76d8 &#8211; \u53d8\u538b\u5668<\/legend><input type='hidden' name='__fluent_form_embded_post_id' value='855' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"e0200fe970\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/es\/wp-json\/wp\/v2\/pages\/855\" \/><div data-type=\"name-element\" data-name=\"names\" class=\" ff-field_container ff-name-field-wrapper\" ><div class='ff-t-container'><div class='ff-t-cell '><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_names_first_name_' id='label_ff_3_names_first_name_'>Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[first_name]\" id=\"ff_3_names_first_name_\" class=\"ff-el-form-control\" placeholder=\"Name*\" aria-invalid=\"false\" aria-required=true><\/div><\/div><\/div><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email'>Email<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"Email*\" data-name=\"email\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_phone' id='label_ff_3_phone'>Phone\/Mobile<\/label><\/div><div class='ff-el-input--content'><input name=\"phone\" class=\"ff-el-form-control ff-el-phone\" type=\"tel\" placeholder=\"Phone*\" data-name=\"phone\" id=\"ff_3_phone\" inputmode=\"tel\"  aria-invalid='false' aria-required=true><\/div><\/div><div class='ff-el-group ff-el-form-hide_label'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_description' id='label_ff_3_description'>Textarea<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_3_description\" name=\"description\" id=\"ff_3_description\" class=\"ff-el-form-control\" rows=\"7\" cols=\"2\" data-name=\"description\" ><\/textarea><\/div><\/div><input type=\"hidden\" name=\"visitor_country\" value=\"unknown\" data-name=\"visitor_country\" ><input type=\"hidden\" name=\"created_at_beijing\" value=\"unknown\" data-name=\"created_at_beijing\" ><input type=\"hidden\" name=\"ai_verdict\" value=\"unknown\" data-name=\"ai_verdict\" ><input type=\"hidden\" name=\"ai_reason\" value=\"unknown\" data-name=\"ai_reason\" ><input type=\"hidden\" name=\"ai_elapsed_ms\" value=\"unknown\" data-name=\"ai_elapsed_ms\" ><input type=\"hidden\" name=\"ai_provider\" value=\"unknown\" data-name=\"ai_provider\" ><input type=\"hidden\" name=\"ai_model\" value=\"unknown\" data-name=\"ai_model\" ><input type=\"hidden\" name=\"ads_eligible\" value=\"unknown\" data-name=\"ads_eligible\" ><input type=\"hidden\" name=\"ads_source\" value=\"unknown\" data-name=\"ads_source\" ><input type=\"hidden\" name=\"gclid\" value=\"unknown\" data-name=\"gclid\" ><input type=\"hidden\" name=\"gbraid\" value=\"unknown\" data-name=\"gbraid\" ><input type=\"hidden\" name=\"wbraid\" value=\"unknown\" data-name=\"wbraid\" ><input type=\"hidden\" name=\"utm_source\" value=\"unknown\" data-name=\"utm_source\" ><input type=\"hidden\" name=\"utm_medium\" value=\"unknown\" data-name=\"utm_medium\" ><input type=\"hidden\" name=\"utm_campaign\" value=\"unknown\" data-name=\"utm_campaign\" ><input type=\"hidden\" name=\"utm_term\" value=\"unknown\" data-name=\"utm_term\" ><input type=\"hidden\" name=\"utm_content\" value=\"unknown\" data-name=\"utm_content\" ><input type=\"hidden\" name=\"landing_page\" value=\"unknown\" data-name=\"landing_page\" ><input type=\"hidden\" name=\"referrer\" value=\"unknown\" data-name=\"referrer\" ><div class='ff-form-inline-style' hidden><style>form.fluent_form_3 .ff-btn-submit:not(.ff_btn_no_style) { background-color: var(--fluentform-primary); color: #ffffff; }<\/style><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Get A Free Quote\">Get A Free Quote<\/button><\/div><\/fieldset><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"asteriskPlacement\":\"asterisk-right\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"names[first_name]\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"names[middle_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"names[last_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global_message\":\"This field must contain a valid email\",\"global\":true}},\"phone\":{\"required\":{\"value\":true,\"global\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\"},\"valid_phone_number\":{\"value\":false,\"global\":true,\"message\":\"Phone number is not valid\",\"global_message\":\"Phone number is not valid\"}},\"description\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>\n            \n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Transformador de potencia: Ofrecemos productos dise\u00f1ados a medida con niveles de voltaje variables para satisfacer los requisitos de las diferentes redes el\u00e9ctricas nacionales y brindamos servicios de OEM. Ventajas del transformador de potencia de Tengyi: El transformador de potencia principal de Tengyi proporciona una transformaci\u00f3n de voltaje eficiente, garantizando \u2026 <\/p>\n<p class=\"read-more-container\"><a title=\"Transformador de potencia\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/es\/power-transformer\/#more-855\" aria-label=\"Leer m\u00e1s sobre Transformador de potencia\">Lee m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-855","page","type-page","status-publish","no-featured-image-padding"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Power Transformer For Sale - Stable &amp; Consistent Power Delivery<\/title>\n<meta name=\"description\" content=\"Tengyi power transformer ensures stable power supply, reliable, efficient, designed for optimal performance. Ideal for large projects. Quote.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Power Transformer For Sale - Stable &amp; Consistent Power Delivery\" \/>\n<meta property=\"og:description\" content=\"Tengyi power transformer ensures stable power supply, reliable, efficient, designed for optimal performance. Ideal for large projects. Quote.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-28T09:56:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/\",\"name\":\"Power Transformer For Sale - Stable & Consistent Power Delivery\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.webp\",\"datePublished\":\"2025-01-09T06:09:41+00:00\",\"dateModified\":\"2026-08-28T09:56:08+00:00\",\"description\":\"Tengyi power transformer ensures stable power supply, reliable, efficient, designed for optimal performance. Ideal for large projects. Quote.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/power-transformer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Power Transformer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Venta de transformadores de potencia - Suministro de potencia estable y constante","description":"El transformador de potencia Tengyi garantiza un suministro el\u00e9ctrico estable, fiable y eficiente, dise\u00f1ado para un rendimiento \u00f3ptimo. Ideal para grandes proyectos. Presupuesto.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/","og_locale":"es_ES","og_type":"article","og_title":"Power Transformer For Sale - Stable & Consistent Power Delivery","og_description":"Tengyi power transformer ensures stable power supply, reliable, efficient, designed for optimal performance. Ideal for large projects. Quote.","og_url":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/","og_site_name":"Tengyi Electric","article_modified_time":"2026-08-28T09:56:08+00:00","og_image":[{"url":"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"13 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/","name":"Venta de transformadores de potencia - Suministro de potencia estable y constante","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/#primaryimage"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp","datePublished":"2025-01-09T06:09:41+00:00","dateModified":"2026-08-28T09:56:08+00:00","description":"El transformador de potencia Tengyi garantiza un suministro el\u00e9ctrico estable, fiable y eficiente, dise\u00f1ado para un rendimiento \u00f3ptimo. Ideal para grandes proyectos. Presupuesto.","breadcrumb":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/power-transformer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Power Transformer"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"Tengyi Electric","description":"Fabricante l\u00edder en transformadores","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"Tengyi Electric","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/pages\/855","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/comments?post=855"}],"version-history":[{"count":1,"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/pages\/855\/revisions"}],"predecessor-version":[{"id":2622,"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/pages\/855\/revisions\/2622"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/es\/wp-json\/wp\/v2\/media?parent=855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}