{"id":2109,"date":"2026-07-27T14:10:38","date_gmt":"2026-07-27T06:10:38","guid":{"rendered":"https:\/\/tengyielectric.com\/?p=2109"},"modified":"2026-07-27T16:46:40","modified_gmt":"2026-07-27T08:46:40","slug":"%d9%a1-%d9%85%d8%b4%d8%b1%d9%88%d8%b9-%d8%aa%d9%88%d8%b1%d9%8a%d8%af-%d9%85%d8%ad%d9%88%d9%84%d8%a7%d8%aa-%d9%83%d9%8a%d9%86%d9%8a%d8%a7-%d9%84%d9%83%d9%8a%d8%a8%d9%8a%d9%84%d8%b3%d9%8a-%d9%84%d9%84","status":"publish","type":"post","link":"https:\/\/tengyielectric.com\/ar\/kenya-kplc-utility-33kv-transformer-project-supply\/","title":{"rendered":"\u0661. \u0645\u0634\u0631\u0648\u0639 \u062a\u0648\u0633\u064a\u0639 \u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0648\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a"},"content":{"rendered":"<div class=\"gb-container gb-container-4e2575b2\">\n<div class=\"gb-container gb-container-8ed3dfe5\">\n\n<h2 class=\"gb-headline gb-headline-f6c8a145 gb-headline-text\">\u0661. \u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u062c\u0647\u062f \u0639\u0627\u0644\u064d \u0645\u062a\u062e\u0635\u0635\u0629 \u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0644\u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0622\u0646\u062f \u0644\u0627\u064a\u062a\u064a\u0646\u063a (KPLC)<\/h2>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ee7d833d\">\n<div class=\"gb-container gb-container-d3395bc0\">\n\n<h3 class=\"wp-block-heading\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0634\u0631\u0648\u0639<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0662. \u0623\u0637\u0644\u0642\u062a \u0634\u0631\u0643\u0629 \u062a\u064a\u0646\u063a\u064a \u0645\u0624\u062e\u0631\u064b\u0627 \u0645\u0634\u0631\u0648\u0639 \u062a\u0648\u0631\u064a\u062f \u0631\u0626\u064a\u0633\u064a \u0644\u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0628\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u0645\u0634\u0631\u0648\u0639 \u062a\u0631\u0642\u064a\u0629 \u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0622\u0646\u062f \u0644\u0627\u064a\u062a\u064a\u0646\u063a (KPLC). \u0648\u0628\u0627\u0644\u062a\u0639\u0627\u0648\u0646 \u0645\u0639 \u0634\u0631\u0643\u0629 \u062a\u0631\u0643\u064a\u0628 \u0645\u062d\u0644\u064a\u0629 \u0628\u0627\u0631\u0632\u0629\u060c \u0646\u062d\u0646 \u0645\u0644\u062a\u0632\u0645\u0648\u0646 \u0628\u062a\u0648\u0631\u064a\u062f \u0645\u0627 \u064a\u0632\u064a\u062f \u0639\u0646 \u0661\u0666\u0660\u0660 \u0648\u062d\u062f\u0629 \u0645\u0646 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u062f\u0627\u0621. \u0648\u0628\u0630\u0644\u0643\u060c \u0641\u0642\u062f \u0627\u062c\u062a\u0627\u0632\u062a \u0627\u0644\u062f\u0641\u0639\u0629 \u0627\u0644\u0623\u0648\u0644\u0649 \u0627\u0644\u0645\u0643\u0648\u064e\u0651\u0646\u0629 \u0645\u0646 \u0661\u0663\u0665 \u0648\u062d\u062f\u0629 \u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639 \u0628\u0646\u062c\u0627\u062d \u0648\u0647\u064a \u0627\u0644\u0622\u0646 \u0641\u064a \u0637\u0631\u064a\u0642\u0647\u0627 \u0625\u0644\u0649 \u0648\u062c\u0647\u062a\u0647\u0627. \u0648\u0642\u062f \u0635\u064f\u0645\u0650\u0651\u0645\u062a \u0647\u0630\u0647 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u0646\u0627\u062e\u064a\u0629 \u0627\u0644\u0635\u0639\u0628\u0629 \u0641\u064a \u0643\u064a\u0646\u064a\u0627\u060c \u0648\u0644\u062a\u0644\u0628\u064a \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u0635\u0627\u0631\u0645\u0629 \u0627\u0644\u062a\u064a \u062d\u062f\u062f\u062a\u0647\u0627 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0622\u0646\u062f \u0644\u0627\u064a\u062a\u064a\u0646\u063a (KPLC).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0663. \u0627\u0644\u062d\u0644\u0648\u0644 \u0627\u0644\u062a\u0642\u0646\u064a\u0629: \u0645\u064f\u062d\u0633\u064e\u0651\u0646\u0629 \u0644\u0634\u0628\u0643\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0664. \u0648\u0644\u062a\u0644\u0628\u064a\u0629 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0625\u0642\u0644\u064a\u0645\u064a \u0628\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\u060c \u0642\u062f\u064e\u0651\u0645\u0646\u0627 \u0645\u062c\u0645\u0648\u0639\u0629\u064b \u0645\u0631\u0646\u0629\u064b \u0645\u0646 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0628\u0633\u0639\u0629 \u0662\u0665 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 \u0648\u0665\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631. \u0623\u0645\u0627 \u0633\u0644\u0633\u0644\u0629 \u0648\u062d\u062f\u0627\u062a \u0665\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631\u060c \u0627\u0644\u062a\u064a \u0635\u064f\u0645\u0650\u0651\u0645\u062a \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u0647\u0630\u0627 \u0627\u0644\u0645\u0634\u0631\u0648\u0639\u060c \u0641\u0647\u064a \u062a\u062a\u0645\u064a\u064e\u0651\u0632 \u0628\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u062a\u0627\u0644\u064a\u0629:<\/p>\n\n\n<div class=\"gb-container gb-container-906366ed\">\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0665. \u0633\u0644\u0627\u0645\u0629 \u0639\u0632\u0644 \u0645\u062a\u0641\u0648\u0650\u0651\u0642\u0629:<\/strong>\u00a0\u0666. \u0648\u0628\u0645\u0627 \u0623\u0646 \u062c\u0647\u062f \u0627\u0644\u0637\u0631\u0641 \u0627\u0644\u0623\u0648\u0644\u064a \u0644\u0647\u0630\u0647 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0647\u0648 \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\u060c \u0641\u0625\u0646\u0647\u0627 \u062a\u062a\u0645\u064a\u0632 \u0628\u0640\u00a0<strong>\u0667. \u0645\u0633\u062a\u0648\u0649 \u062a\u0623\u062b\u064a\u0631 \u0627\u0644\u0628\u0631\u0642 (BIL) \u0627\u0644\u0628\u0627\u0644\u063a \u0661\u0667\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a<\/strong>\u00a0\u0668. \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u062a\u0631\u062f\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0628\u0627\u0644\u063a\u0629 \u0667\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a. \u0648\u064a\u0636\u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0645\u0639\u0632\u064e\u0651\u0632 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u0634\u0628\u0643\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u062f\u0649 \u0627\u0644\u0637\u0648\u064a\u0644 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u0629 \u0648\u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u0645\u0639\u0631\u064e\u0651\u0636\u0629 \u0628\u0643\u062b\u0631\u0629 \u0644\u0644\u0628\u0631\u0642 \u0639\u0628\u0631 \u0625\u0641\u0631\u064a\u0642\u064a\u0627.<\/li>\n\n\n\n<li><strong>\u0669. \u062e\u064a\u0627\u0631\u0627\u062a \u0645\u0648\u0627\u062f \u0631\u0627\u0642\u064a\u0629:<\/strong>\u00a0\u0661\u0660. \u0648\u0627\u0633\u062a\u0646\u0627\u062f\u064b\u0627 \u0625\u0644\u0649 \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u062f\u0629 \u0644\u0645\u062e\u062a\u0644\u0641 \u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u0634\u0631\u0648\u0639\u060c \u0642\u062f\u064e\u0651\u0645\u0646\u0627 \u0643\u0644\u064b\u0651\u0627 \u0645\u0646 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0646\u062d\u0627\u0633\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u062f\u0627\u0621 <strong>\u0661\u0661. \u0648\u0627\u0644\u0646\u062d\u0627\u0633\u064a\u0629<\/strong> \u0661\u0662. \u0648\u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645\u064a\u0629 \u0627\u0644\u0627\u0642\u062a\u0635\u0627\u062f\u064a\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 <strong>\u0661\u0663. \u0648\u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645\u064a\u0629<\/strong> \u0661\u0664. \u0648\u0642\u062f \u062a\u0645\u064a\u064e\u0651\u0632\u062a \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0646\u062d\u0627\u0633\u064a\u0629 \u0628\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u062d\u0631\u0627\u0631\u064a \u0645\u062a\u0641\u0648\u0650\u0651\u0642 \u0648\u062e\u0633\u0627\u0626\u0631 \u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0623\u0642\u0644 (\u062e\u0633\u0627\u0631\u0629 \u0627\u0644\u062e\u0644\u0648 \u0639\u0646\u062f \u0661\u0666\u0660 \u0648\u0627\u0637).<\/li>\n\n\n\n<li><strong>\u0661\u0665. \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0645\u0644\u062d\u0642\u0627\u062a:<\/strong>\u00a0\u0661\u0666. \u0645\u062a\u0648\u0627\u0641\u0642\u0629 \u062a\u0645\u0627\u0645\u064b\u0627 \u0645\u0639 \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631\u00a0<strong>\u0661\u0667. IEC 60076<\/strong>\u00a0\u0661\u0668. \u0648\u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a (vector group) \u0644\u0642\u0645\u0639 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a\u0627\u062a\u060c \u0641\u0625\u0646 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0632\u0648\u064e\u0651\u062f\u0629 \u0628\u0645\u0644\u062d\u0642\u0627\u062a \u0642\u064a\u0627\u0633\u064a\u0629 \u062a\u0633\u062a\u062e\u062f\u0645\u0647\u0627 \u0634\u0631\u0643\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u060c \u0648\u0645\u0646\u0647\u0627 \u0645\u0624\u0634\u0631\u0627\u062a \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u064a\u062a (OTI)\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u062a\u062e\u0641\u064a\u0641 \u0627\u0644\u0636\u063a\u0637\u060c \u0648\u0635\u0647\u0627\u0631\u064a\u062c \u0627\u0644\u062a\u062e\u0632\u064a\u0646 (conservator tanks).\u00a0<strong>\u062f\u0627\u064a\u0646 11<\/strong>\u00a0\u0662\u0660. \u0631\u0642\u0645.<\/li>\n<\/ul>\n\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\u0662\u0661. \u0627\u0644\u0645\u0639\u0644\u064e\u0651\u0645\u0629.<\/td><td>&nbsp; \u0662\u0662. \u063a\u0627\u0645\u0631\u0629 \u0628\u0627\u0644\u0632\u064a\u062a\u060c \u0648\u062a\u0628\u0631\u064a\u062f \u0630\u0627\u062a\u064a (ONAN)<\/td><td>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/td><\/tr><tr><td>1&nbsp;<\/td><td>\u0646\u0648\u0639 \u0627\u0644\u0645\u062d\u0648\u0644<\/td><td>\u0662\u0663. \u0627\u0644\u0646\u0645\u0648\u0630\u062c<\/td><\/tr><tr><td>2&nbsp;<\/td><td>\u0662\u0664. S-M-50-33\/0.415<\/td><td>\u0662\u0665. \u0665\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631<\/td><\/tr><tr><td>3&nbsp;<\/td><td>\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/td><td>\u0662\u0666. \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0627\u0628\u062a\u062f\u0627\u0626\u064a (\u0639\u0627\u0644\u064a \u0627\u0644\u062c\u0647\u062f)<\/td><\/tr><tr><td>4&nbsp;<\/td><td>\u0662\u0667. \u0663\u0663\u0660\u0660\u0660 \u0641\u0648\u0644\u062a (\u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a)<\/td><td>\u0662\u0668. \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u062b\u0627\u0646\u0648\u064a (\u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062c\u0647\u062f)<\/td><\/tr><tr><td>5&nbsp;<\/td><td>\u0662\u0669. \u0664\u0661\u0665 \u0641\u0648\u0644\u062a\u060c \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0637\u0648\u0631\u060c \u0623\u0631\u0628\u0639 \u0623\u0633\u0644\u0627\u0643<\/td><td>\u0663\u0660. \u0627\u0644\u0645\u062e\u0631\u062c \u0628\u064a\u0646 \u0627\u0644\u0637\u0648\u0631 \u0648\u0627\u0644\u0645\u062d\u0627\u064a\u062f<\/td><\/tr><tr><td>6&nbsp;<\/td><td>\u0663\u0661. \u0662\u0664\u0660 \u0641\u0648\u0644\u062a<\/td><td>\u0663\u0662. \u0665\u0660 \u0647\u0631\u062a\u0632<\/td><\/tr><tr><td>7&nbsp;<\/td><td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td><td>\u0663\u0663. ONAN (\u062a\u0628\u0631\u064a\u062f \u0637\u0628\u064a\u0639\u064a \u0628\u0627\u0644\u0632\u064a\u062a \u0648\u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0637\u0628\u064a\u0639\u064a)<\/td><\/tr><tr><td>8&nbsp;<\/td><td>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td>\u062f\u0627\u064a\u0646 11<\/td><\/tr><tr><td>9&nbsp;<\/td><td>\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0628\u0631\u064a\u062f<\/td><td>\u0663\u0664. \u0646\u062d\u0627\u0633<\/td><\/tr><tr><td>10&nbsp;<\/td><td>\u0645\u0627\u062f\u0629 \u0627\u0644\u0644\u0641<\/td><td>\u0663\u0665. \u062e\u0633\u0627\u0631\u0629 \u0627\u0644\u062e\u0644\u0648<\/td><\/tr><tr><td>11&nbsp;<\/td><td>\u0663\u0666. \u0661\u0666\u0660 \u0648\u0627\u0637<\/td><td>\u0663\u0667. \u062e\u0633\u0627\u0631\u0629 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (\u0639\u0646\u062f \u0667\u0665\u00b0\u0645)<\/td><\/tr><tr><td>12&nbsp;<\/td><td>\u0663\u0668. \u0661\u0662\u0660\u0660 \u0648\u0627\u0637<\/td><td>1,200W<\/td><\/tr><tr><td>13&nbsp;<\/td><td>\u0661. \u0627\u0644\u062a\u064a\u0627\u0631 \u0628\u062f\u0648\u0646 \u062d\u0645\u0644<\/td><td>0.6%<\/td><\/tr><tr><td>14&nbsp;<\/td><td>\u0662. \u062c\u0647\u062f \u0627\u0644\u0645\u0639\u0627\u0648\u0642\u0629 (\u0639\u0646\u062f \u0667\u0665 \u00b0\u0645)<\/td><td>\u0663. \u0664\u0661 \u062a\u064a \u0628\u064a \u0663 \u062a\u064a \u00b1 \u0661\u0660\u0661 \u062a\u064a \u0628\u064a \u0663 \u062a\u064a (\u0627\u0644\u062a\u0633\u0627\u0645\u062d)<\/td><\/tr><tr><td>15&nbsp;<\/td><td>\u0664. \u0645\u0646\u0638\u0651\u0645 \u0627\u0644\u062c\u0647\u062f \u0628\u0627\u0644\u0645\u062d\u0637\u0627\u062a<\/td><td>\u0665. \u0645\u0646\u0638\u0651\u0645 \u0627\u0644\u062c\u0647\u062f \u0628\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0645\u064f\u062a\u062f\u0631\u062c \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0627\u0644\u062c\u0627\u0646\u0628 \u0639\u0627\u0644\u064a \u0627\u0644\u062c\u0647\u062f\u060c \u00b1 \u0662\u00d7\u0662,\u0665\u0661 \u062a\u064a \u0628\u064a \u0663 \u062a\u064a<\/td><\/tr><tr><td>16&nbsp;<\/td><td>\u0666. \u0623\u0642\u0635\u0649 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0645\u062d\u064a\u0637\u0629<\/td><td>\u0667. \u0664\u0660 \u00b0\u0645<\/td><\/tr><tr><td>17&nbsp;<\/td><td>\u0668. \u0623\u0642\u0635\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u0641\u064a \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0644\u0641\u0627\u0626\u0641<\/td><td>\u0669. \u0666\u0665 \u0643\u0644\u0641\u0646 (\u0645\u062a\u0648\u0633\u0637)\/ \u0667\u0668 \u0643\u0644\u0641\u0646 (\u0623\u0639\u0644\u0649 \u0646\u0642\u0637\u0629 \u062d\u0631\u0627\u0631\u0629)<\/td><\/tr><tr><td>18&nbsp;<\/td><td>\u0661\u0660. \u0623\u0642\u0635\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u0641\u064a \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u064a\u062a<\/td><td>\u0661\u0661. \u0665\u0665 \u0643\u0644\u0641\u0646<\/td><\/tr><tr><td>19&nbsp;<\/td><td>\u0661\u0662. \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0639\u0627\u0644\u064a \u0644\u0644\u062c\u0647\u062f \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u0627\u0644\u0635\u0648\u0627\u0639\u0642 (BIL) (\u0630\u0631\u0648\u0629 \u0645\u0648\u062c\u0629 \u0635\u0627\u0639\u0642\u0629 \u0643\u0627\u0645\u0644\u0629)<\/td><td>\u0661. \u0661\u0667\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a (\u0630\u0631\u0648\u0629)<\/td><\/tr><tr><td>20&nbsp;<\/td><td>\u0662. \u0645\u0648\u062c\u0629 \u062c\u0647\u062f \u0639\u0627\u0644\u064a \u0645\u0642\u0637\u0648\u0639\u0629<\/td><td>\u0663. \u0661\u0669\u0665 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a (\u0630\u0631\u0648\u0629)<\/td><\/tr><tr><td>21&nbsp;<\/td><td>\u0664. \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0639\u0646\u062f \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a<\/td><td>\u0665. \u0667\u0660 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a (\u062c\u0630\u0631 \u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0645\u0631\u0628\u0639\u0627\u062a\u060c \u0644\u0645\u062f\u0629 \u062f\u0642\u064a\u0642\u0629 \u0648\u0627\u062d\u062f\u0629)<\/td><\/tr><tr><td>22&nbsp;<\/td><td>\u0666. \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 \u0639\u0646\u062f \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a<\/td><td>\u0667. \u0665 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a (\u062c\u0630\u0631 \u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0645\u0631\u0628\u0639\u0627\u062a\u060c \u0644\u0645\u062f\u0629 \u062f\u0642\u064a\u0642\u0629 \u0648\u0627\u062d\u062f\u0629)<\/td><\/tr><tr><td>23&nbsp;<\/td><td>\u0668. \u0623\u0642\u0635\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u0639\u0646 \u0633\u0637\u062d \u0627\u0644\u0628\u062d\u0631<\/td><td>\u0669. \u0661\u0660\u0660\u0660 \u0645\u062a\u0631<\/td><\/tr><tr><td>24&nbsp;<\/td><td>\u0661\u0660. \u0627\u0644\u0645\u062f\u0629 \u0627\u0644\u0645\u0633\u0645\u0648\u062d \u0628\u0647\u0627 \u0644\u062d\u062f\u0648\u062b \u0627\u0644\u0642\u0635\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td><td>\u0661\u0661. \u062b\u0627\u0646\u064a\u062a\u0627\u0646<\/td><\/tr><tr><td>25&nbsp;<\/td><td>\u0661\u0662. \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0639\u0632\u0644<\/td><td>\u0661\u0663. \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 \u0627\u0644\u0622\u064a \u0625\u064a \u0633\u064a \u0666\u0660\u0660\u0667\u0666-\u0663 (\u0641\u0626\u0629 \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a)<\/td><\/tr><tr><td>26&nbsp;<\/td><td>\u0661\u0664. \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0636\u0648\u0636\u0627\u0621<\/td><td>\u0661\u0665. \u0665\u0663 \u062f\u064a\u0633\u064a\u0628\u0644 (\u0623)<\/td><\/tr><tr><td>27&nbsp;<\/td><td>\u0661\u0666. \u0646\u0648\u0639 \u0627\u0644\u062e\u0632\u0627\u0646<\/td><td>\u0661\u0667. \u062e\u0632\u0627\u0646 \u0645\u063a\u0644\u0642 \u0623\u0648 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0630\u064a \u0627\u0644\u062e\u0632\u0627\u0646 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a<\/td><\/tr><tr><td>28&nbsp;<\/td><td>\u0661\u0668. \u0627\u0644\u062a\u0634\u0637\u064a\u0628<\/td><td>\u0661\u0669. \u0631\u0645\u0627\u062f\u064a \u0641\u0627\u062a\u062d \u0623\u0648 \u0631\u0627\u0644 \u0667\u0660\u0663\u0665<\/td><\/tr><tr><td>29&nbsp;<\/td><td>\u0662\u0660. \u0627\u0644\u0623\u0628\u0639\u0627\u062f (\u0627\u0644\u0637\u0648\u0644 \u00d7 \u0627\u0644\u0639\u0631\u0636 \u00d7 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639)<\/td><td>\u0662\u0661. \u0669\u0668\u0660 \u00d7 \u0668\u0660\u0660 \u00d7 \u0661\u0667\u0660\u0660 \u0645\u0645<\/td><\/tr><tr><td>30&nbsp;<\/td><td>\u0662\u0662. \u0627\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629<\/td><td>\u0662\u0663. \u0660\u066b\u0667\u0667 \u0637\u0646 (\u0627\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0641\u0639\u0651\u0627\u0644\u0629: \u0660\u066b\u0663 \u0637\u0646\u060c \u0627\u0644\u0632\u064a\u062a: \u0660\u066b\u0662\u0666\u0665 \u0637\u0646)<\/td><\/tr><tr><td>31&nbsp;<\/td><td>\u0662\u0664. \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0637\u0628\u064e\u0651\u0642\u0629<\/td><td>\u0662\u0665. \u0627\u0644\u0622\u064a \u0625\u064a \u0633\u064a \u0666\u0660\u0660\u0667\u0666-\u0661\u060c -\u0662\u060c -\u0663\u060c -\u0665\u060c -\u0661\u0660<\/td><\/tr><tr><td colspan=\"3\" rowspan=\"2\">\u0662\u0666. \u0627\u0644\u0645\u0644\u062d\u0642\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629:<br>\u00a0\u0662\u0667. \u00b7 \u062e\u0632\u0627\u0646 \u0627\u062d\u062a\u064a\u0627\u0637\u064a \u0645\u0632\u0648\u064e\u0651\u062f \u0645\u0624\u0634\u0631 \u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0632\u064a\u062a<br>\u00a0\u0662\u0668. \u00b7 \u062c\u0647\u0627\u0632 \u062a\u062e\u0641\u064a\u0641 \u0627\u0644\u0636\u063a\u0637<br>\u00a0\u0662\u0669. \u00b7 \u0645\u0624\u0634\u0631 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u064a\u062a (OTI)<br>\u00a0\u0663\u0660. \u00b7 \u0635\u0645\u0627\u0645 \u062a\u0635\u0631\u064a\u0641 \u0627\u0644\u0632\u064a\u062a \u0648\u0635\u0645\u0627\u0645 \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a<br>\u00a0\u0663\u0661. \u00b7 \u0645\u0642\u0627\u0628\u0636 \u0627\u0644\u0631\u0641\u0639 \u0648\u0628\u0637\u0627\u0642\u0627\u062a \u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a<br>\u00a0\u0663\u0662. \u00b7 \u0637\u0631\u0641\u064a\u0627\u062a \u0627\u0644\u062a\u0623\u0631\u064a\u0636 (\u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644 \u0627\u062b\u0646\u062a\u0627\u0646)<br>\u00a0\u0663\u0663. \u00b7 \u0644\u0648\u062d\u0629 \u0627\u0644\u0627\u0633\u0645 \u0648\u0644\u0648\u062d\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0641 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 \u0627\u0644\u0622\u064a \u0625\u064a \u0633\u064a \u0666\u0660\u0660\u0667\u0666<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u0663\u0664. \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0639\u0644\u0649 \u0646\u0637\u0627\u0642 \u0648\u0627\u0633\u0639 \u0648\u0627\u0644\u062a\u0633\u0644\u064a\u0645 \u0627\u0644\u0645\u0648\u062b\u0648\u0642<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0663\u0665. \u0648\u0644\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0627\u0644\u062a\u0632\u0627\u0645 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a \u0627\u0644\u0628\u0627\u0644\u063a \u0623\u0643\u062b\u0631 \u0645\u0646 \u0661\u0666\u0660\u0660 \u0648\u062d\u062f\u0629 \u0628\u0643\u0641\u0627\u0621\u0629\u060c \u0623\u0646\u0634\u0623\u062a \u0634\u0631\u0643\u0629 \u062a\u064a\u0646\u063a\u064a \u0622\u0644\u064a\u0629 \u062a\u0633\u0644\u064a\u0645 \u0645\u062a\u0633\u0644\u0633\u0644\u0629 \u0642\u0648\u064a\u0629. \u0648\u0644\u0634\u062d\u0646\u0629 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0623\u0648\u0644\u0649 \u0627\u0644\u0628\u0627\u0644\u063a \u0639\u062f\u062f\u0647\u0627 \u0661\u0663\u0665 \u0648\u062d\u062f\u0629\u060c \u0646\u0641\u064e\u0651\u0630\u0646\u0627 \u0628\u0631\u0648\u062a\u0648\u0643\u0648\u0644\u0627\u062a \u062a\u0635\u062f\u064a\u0631 \u0645\u062a\u062e\u0635\u0635\u0629 \u0644\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0628\u062d\u0631\u064a \u0648\u0627\u0644\u0628\u0631\u064a:<\/p>\n\n\n<div class=\"gb-container gb-container-38d601f3\">\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0663\u0666. \u0627\u0644\u062a\u062e\u0641\u064a\u0641 \u0645\u0646 \u0627\u0644\u0645\u062e\u0627\u0637\u0631:<\/strong>\u00a0\u0663\u0667. \u062a\u0645 \u062a\u063a\u0644\u064a\u0641 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0628\u063a\u0634\u0627\u0621 \u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0625\u062f\u062e\u0627\u0644\u0647\u0627 \u0641\u064a \u0635\u0646\u0627\u062f\u064a\u0642 \u062a\u0635\u062f\u064a\u0631 \u0645\u062a\u064a\u0646\u0629 \u0645\u0639 \u062a\u062b\u0628\u064a\u062a \u0627\u062d\u062a\u0631\u0627\u0641\u064a \u062f\u0627\u062e\u0644 \u0627\u0644\u062d\u0627\u0648\u064a\u0627\u062a. \u0648\u0647\u0630\u0627 \u064a\u0645\u0646\u0639\u00a0<strong>\u0663\u0668. \u0627\u0644\u0623\u0643\u0633\u062f\u0629 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0647\u0648\u0627\u0621 \u0627\u0644\u0628\u062d\u0631 \u0627\u0644\u0645\u0627\u0644\u062d<\/strong>\u00a0\u0663\u0669. \u0648\u064a\u0642\u0636\u064a \u0639\u0644\u0649 \u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0645\u062b\u0644\u00a0<strong>\u0664\u0660. \u0643\u0633\u0631 \u0627\u0644\u0639\u0648\u0627\u0632\u0644<\/strong>\u00a0\u0664\u0661. \u0623\u0648\u00a0<strong>\u0664\u0662. \u0627\u0646\u0632\u064a\u0627\u062d \u0627\u0644\u0646\u0648\u0627\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629<\/strong>\u00a0\u0664\u0663. \u0627\u0644\u0646\u0627\u062c\u0645 \u0639\u0646 \u0638\u0631\u0648\u0641 \u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0635\u0639\u0628\u0629.<\/li>\n\n\n\n<li><strong>\u0664\u0664. \u0627\u0644\u0644\u0648\u062c\u0633\u062a\u064a\u0627\u062a \u0627\u0644\u0641\u0639\u0651\u0627\u0644\u0629:<\/strong>\u00a0\u0664\u0665. \u062c\u0645\u064a\u0639 \u0645\u0648\u0627\u062f \u0627\u0644\u062a\u063a\u0644\u064a\u0641 \u0645\u064f\u0637\u0627\u0628\u0650\u0642\u0629 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 \u0627\u0644\u062f\u0648\u0644\u064a ISPM 15\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u062e\u0644\u064a\u0635 \u0627\u0644\u062c\u0645\u0631\u0643\u064a \u0627\u0644\u0633\u0644\u0633 \u0641\u064a \u0645\u064a\u0646\u0627\u0621 \u0645\u0648\u0645\u0628\u0627\u0633\u0627 \u0648\u0627\u0644\u0648\u0635\u0648\u0644 \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u062d\u062f\u062f \u0625\u0644\u0649 \u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628.<\/li>\n<\/ul>\n\n<\/div>\n\n<div class=\"gb-container gb-container-6359cff9\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-409817e6\">\n<div class=\"gb-grid-column gb-grid-column-1ba69ffc\"><div class=\"gb-container gb-container-1ba69ffc\">\n\n<figure class=\"gb-block-image gb-block-image-471355e3\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"1100\" class=\"gb-image gb-image-471355e3\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp\" alt=\"\" title=\"\u0662. \u0645\u0634\u0631\u0648\u0639 \u0634\u0628\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u2013 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (KPLC)\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp 1500w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project-300x220.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project-1024x751.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project-768x563.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project-16x12.webp 16w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-aeed8dde\"><div class=\"gb-container gb-container-aeed8dde\">\n\n<figure class=\"gb-block-image gb-block-image-38891d4a\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"1100\" class=\"gb-image gb-image-38891d4a\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2.jpg\" alt=\"\" title=\"\u0661. \u0643\u064a\u0646\u064a\u0627-\u0643\u064a\u0628\u064a\u0644\u0633\u064a-\u0645\u0634\u0631\u0648\u0639 \u0627\u0644\u0634\u0628\u0643\u0629 \u0662\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2.jpg 1500w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2-300x220.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2-1024x751.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2-768x563.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project2-16x12.webp 16w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-e0ea4e6e\"><div class=\"gb-container gb-container-e0ea4e6e\">\n\n<figure class=\"gb-block-image gb-block-image-d16bb4be\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"1100\" class=\"gb-image gb-image-d16bb4be\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3.jpg\" alt=\"\" title=\"\u0662. \u0643\u064a\u0646\u064a\u0627-\u0643\u064a\u0628\u064a\u0644\u0633\u064a-\u0645\u0634\u0631\u0648\u0639 \u0627\u0644\u0634\u0628\u0643\u0629 \u0663\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3.jpg 1500w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3-300x220.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3-1024x751.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3-768x563.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project3-16x12.webp 16w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6ec3ed39\"><div class=\"gb-container gb-container-6ec3ed39\">\n\n<figure class=\"gb-block-image gb-block-image-380aa3b8\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"1100\" class=\"gb-image gb-image-380aa3b8\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4.jpg\" alt=\"\" title=\"\u0663. \u0643\u064a\u0646\u064a\u0627-\u0643\u064a\u0628\u064a\u0644\u0633\u064a-\u0645\u0634\u0631\u0648\u0639 \u0627\u0644\u0634\u0628\u0643\u0629 \u0664\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4.jpg 1500w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4-300x220.webp 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4-1024x751.webp 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4-768x563.webp 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project4-16x12.webp 16w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>\u0664\u0666. \u0627\u0644\u0645\u0644\u062e\u0651\u0635<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0664\u0667. \u064a\u0645\u062b\u0644 \u0627\u0644\u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0646\u0627\u062c\u062d \u0644\u0623\u0648\u0644 \u0661\u0663\u0665 \u0648\u062d\u062f\u0629 \u0628\u062f\u0627\u064a\u0629 \u062e\u0637\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0645\u062a\u062f\u0631\u0651\u062c \u0644\u0640\u0661\u0666\u0660\u0660 \u0645\u062d\u0648\u0644\u064d \u0641\u064a \u0643\u064a\u0646\u064a\u0627. \u0648\u0647\u0630\u0647 \u0627\u0644\u062a\u0632\u0627\u0645\u0627\u062a \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0648\u0627\u0633\u0639\u0629 \u0627\u0644\u0646\u0637\u0627\u0642 \u062a\u0624\u0643\u062f \u0645\u062c\u062f\u062f\u064b\u0627 \u0642\u062f\u0631\u0629 \u0634\u0631\u0643\u0629 \u062a\u064a\u0646\u063a\u064a \u0643\u0645\u0648\u0631\u062f \u0631\u0627\u0626\u062f \u0644\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0639\u0627\u0645\u0629. \u0648\u0641\u064a \u0627\u0644\u0646\u0647\u0627\u064a\u0629\u060c \u062a\u0648\u0641\u0631 \u0647\u0630\u0647 \u0627\u0644\u0634\u0631\u0627\u0643\u0629 \u201c\u0627\u0644\u064a\u0642\u064a\u0646 \u0627\u0644\u062a\u0642\u0646\u064a\u201d \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0627\u0644\u0644\u0627\u0632\u0645 \u0644\u0646\u062c\u0627\u062d \u062a\u062d\u062f\u064a\u062b \u0634\u0628\u0643\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u0643\u064a\u0646\u064a\u0629.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"\u0664. \u0645\u0634\u0631\u0648\u0639 \u0643\u064a\u0646\u064a\u0627 \u0644\u0643\u064a\u0628\u064a\u0644\u0633\u064a: \u0634\u062d\u0646 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0628\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/FBwZNc6YnGA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b884af38\">\n<div class=\"gb-container gb-container-0d997913\">\n<div class=\"gb-container gb-container-12d6c45c\">\n<div class=\"gb-container gb-container-e4b92954\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-c263af85\">\n<div class=\"gb-grid-column gb-grid-column-be74dc72\"><div class=\"gb-container gb-container-be74dc72\">\n\n<p class=\"gb-headline gb-headline-a01f4858 gb-headline-text\">\u0664\u0668. \u0639\u0632\u0650\u0651\u0632 \u0634\u0628\u0643\u062a\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0628\u062e\u0628\u0631\u0629 \u062a\u064a\u0646\u063a\u064a \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0629<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0661. \u062a\u064f\u0648\u0641\u0650\u0651\u0631 \u0634\u0631\u0643\u0629 \u00ab\u062a\u064a\u0646\u063a\u064a\u00bb \u0627\u0644\u064a\u0642\u064a\u0646 \u0627\u0644\u062a\u0642\u0646\u064a \u0627\u0644\u0630\u064a \u062a\u062a\u0637\u0644\u0628\u0647 \u0645\u0634\u0627\u0631\u064a\u0639\u0643 \u0627\u0644\u062d\u064a\u0648\u064a\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u0634\u0628\u0643\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0639\u0627\u0644\u0645. \u0641\u0645\u0646\u0630 \u062d\u0644\u0648\u0644\u0646\u0627 \u0627\u0644\u0645\u064f\u0635\u0646\u064e\u0651\u0641\u0629 \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0639\u0627\u0645 \u0628\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\u060c \u0648\u0627\u0644\u0645\u064f\u062d\u0633\u064e\u0651\u0646\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u0634\u0628\u0643\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0623\u0641\u0631\u064a\u0642\u064a\u0629\u060c \u0648\u0635\u0648\u0644\u064b\u0627 \u0625\u0644\u0649 \u0633\u0644\u0633\u0644\u062a\u0646\u0627 \u0627\u0644\u062d\u0635\u0631\u064a\u0629 \u0644\u0644\u0645\u0646\u0637\u0642\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629 (\u0627\u0644\u062a\u064a \u062a\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 IEEE\/ANSI)\u060c \u064a\u0642\u062f\u0650\u0651\u0645 \u0641\u0631\u064a\u0642 \u062e\u0628\u0631\u0627\u0626\u0646\u0627 \u0627\u0644\u062f\u0642\u0629 \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0648\u0627\u0644\u062e\u062f\u0645\u0627\u062a \u0627\u0644\u0644\u0648\u062c\u0633\u062a\u064a\u0629 \u0627\u0644\u0622\u0645\u0646\u0629 \u0627\u0644\u0644\u0627\u0632\u0645\u0629 \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0642\u0631 \u0648\u0627\u0644\u0637\u0648\u064a\u0644 \u0627\u0644\u0623\u0645\u062f \u062d\u062a\u0649 \u0641\u064a \u0623\u0643\u062b\u0631 \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u062a\u062d\u062f\u064a\u064b\u0627.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-3726250d\"><div class=\"gb-container gb-container-3726250d\">\n<div class=\"gb-container gb-container-4f0d8dd7\">\n\n<a class=\"gb-button gb-button-7d9b861c gb-button-text\" href=\"#popmake-561\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u0662. \u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0645\u062a\u062e\u0635\u0635\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0644\u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0648\u0625\u0636\u0627\u0621\u0629 (KPLC) \u2014 \u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0634\u0631\u0648\u0639: \u0623\u0637\u0644\u0642\u062a \u0634\u0631\u0643\u0629 \u062a\u064a\u0646\u063a\u064a \u0645\u0624\u062e\u0631\u064b\u0627 \u0645\u0634\u0631\u0648\u0639 \u062a\u0648\u0631\u064a\u062f \u0631\u0626\u064a\u0633\u064a \u0644\u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0628\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u062a\u0631\u0642\u064a\u0629 \u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0648\u0625\u0636\u0627\u0621\u0629 (KPLC). \u0648\u0628\u0627\u0644\u062a\u0639\u0627\u0648\u0646 \u0645\u0639 \u0634\u0631\u0643\u0629 \u0628\u0627\u0631\u0632\u0629\u2026 <\/p>\n<p class=\"read-more-container\"><a title=\"\u0661. \u0645\u0634\u0631\u0648\u0639 \u062a\u0648\u0633\u064a\u0639 \u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0628\u0627\u0648\u0631 \u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0648\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/ar\/kenya-kplc-utility-33kv-transformer-project-supply\/#more-2109\" aria-label=\"\u0627\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f \u0639\u0646 \u062a\u0648\u0633\u064a\u0639 \u0634\u0628\u0643\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0641\u064a \u0643\u064a\u0646\u064a\u0627 \u0648\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u062a\u0648\u0631\u064a\u062f\u0647\u0627\">\u0627\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f<\/a><\/p>","protected":false},"author":2,"featured_media":2111,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-2109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cases","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>33kV Distribution Transformers for Kenya KPLC Utility Grid<\/title>\n<meta name=\"description\" content=\"Delivered 135 units of 33kV transformers for Kenya KPLC, part of a 1,600+ order. High-performance copper and aluminum winding grid solutions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"33kV Distribution Transformers for Kenya KPLC Utility Grid\" \/>\n<meta property=\"og:description\" content=\"Delivered 135 units of 33kV transformers for Kenya KPLC, part of a 1,600+ order. High-performance copper and aluminum winding grid solutions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-27T06:10:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-27T08:46:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"1100\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"TYElectric\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"TYElectric\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/\"},\"author\":{\"name\":\"TYElectric\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\"},\"headline\":\"Kenya Power Utility Grid Expansion Distribution Transformer Supply\",\"datePublished\":\"2026-07-27T06:10:38+00:00\",\"dateModified\":\"2026-07-27T08:46:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/\"},\"wordCount\":700,\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Kenya-KPLC-Grid-Project.webp\",\"articleSection\":[\"Cases\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/\",\"name\":\"33kV Distribution Transformers for Kenya KPLC Utility Grid\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Kenya-KPLC-Grid-Project.webp\",\"datePublished\":\"2026-07-27T06:10:38+00:00\",\"dateModified\":\"2026-07-27T08:46:40+00:00\",\"description\":\"Delivered 135 units of 33kV transformers for Kenya KPLC, part of a 1,600+ order. High-performance copper and aluminum winding grid solutions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Kenya-KPLC-Grid-Project.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Kenya-KPLC-Grid-Project.webp\",\"width\":1500,\"height\":1100},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/kenya-kplc-utility-33kv-transformer-project-supply\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Kenya Power Utility Grid Expansion Distribution Transformer Supply\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\",\"name\":\"TYElectric\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"caption\":\"TYElectric\"},\"url\":\"https:\\\/\\\/tengyielectric.com\\\/ar\\\/author\\\/tyelectric\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0661. \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (KPLC) \u0627\u0644\u0639\u0627\u0645\u0629","description":"\u0633\u064f\u0644\u0650\u0651\u0645\u064e \u0661\u0663\u0665 \u0648\u062d\u062f\u0629\u064b \u0645\u0646 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u0635\u0627\u0644\u062d \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (KPLC)\u060c \u0648\u0647\u064a \u062c\u0632\u0621\u064c \u0645\u0646 \u0637\u0644\u0628\u064a\u0629 \u062a\u0636\u0645 \u0623\u0643\u062b\u0631 \u0645\u0646 \u0661\u0666\u0660\u0660 \u0648\u062d\u062f\u0629. \u062d\u0644\u0648\u0644 \u0634\u0628\u0643\u0627\u062a \u0644\u0641\u0627\u0626\u0641 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u062f\u0627\u0621 \u0645\u0635\u0646\u0648\u0639\u0629 \u0645\u0646 \u0627\u0644\u0646\u062d\u0627\u0633 \u0648\u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/","og_locale":"ar_AR","og_type":"article","og_title":"33kV Distribution Transformers for Kenya KPLC Utility Grid","og_description":"Delivered 135 units of 33kV transformers for Kenya KPLC, part of a 1,600+ order. High-performance copper and aluminum winding grid solutions.","og_url":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/","og_site_name":"Tengyi Electric","article_published_time":"2026-07-27T06:10:38+00:00","article_modified_time":"2026-07-27T08:46:40+00:00","og_image":[{"width":1500,"height":1100,"url":"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp","type":"image\/webp"}],"author":"TYElectric","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"TYElectric","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"5 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#article","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/"},"author":{"name":"TYElectric","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896"},"headline":"Kenya Power Utility Grid Expansion Distribution Transformer Supply","datePublished":"2026-07-27T06:10:38+00:00","dateModified":"2026-07-27T08:46:40+00:00","mainEntityOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/"},"wordCount":700,"publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp","articleSection":["Cases"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/","name":"\u0661. \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u0634\u0628\u0643\u0629 \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (KPLC) \u0627\u0644\u0639\u0627\u0645\u0629","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#primaryimage"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp","datePublished":"2026-07-27T06:10:38+00:00","dateModified":"2026-07-27T08:46:40+00:00","description":"\u0633\u064f\u0644\u0650\u0651\u0645\u064e \u0661\u0663\u0665 \u0648\u062d\u062f\u0629\u064b \u0645\u0646 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0663\u0663 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0644\u0635\u0627\u0644\u062d \u0634\u0631\u0643\u0629 \u0643\u064a\u0646\u064a\u0627 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (KPLC)\u060c \u0648\u0647\u064a \u062c\u0632\u0621\u064c \u0645\u0646 \u0637\u0644\u0628\u064a\u0629 \u062a\u0636\u0645 \u0623\u0643\u062b\u0631 \u0645\u0646 \u0661\u0666\u0660\u0660 \u0648\u062d\u062f\u0629. \u062d\u0644\u0648\u0644 \u0634\u0628\u0643\u0627\u062a \u0644\u0641\u0627\u0626\u0641 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u062f\u0627\u0621 \u0645\u0635\u0646\u0648\u0639\u0629 \u0645\u0646 \u0627\u0644\u0646\u062d\u0627\u0633 \u0648\u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645.","breadcrumb":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2026\/07\/Kenya-KPLC-Grid-Project.webp","width":1500,"height":1100},{"@type":"BreadcrumbList","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/kenya-kplc-utility-33kv-transformer-project-supply\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Kenya Power Utility Grid Expansion Distribution Transformer Supply"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","description":"\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0631\u0627\u0626\u062f\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896","name":"TYElectric","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","caption":"TYElectric"},"url":"https:\/\/tengyielectric.com\/ar\/author\/tyelectric\/"}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts\/2109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/comments?post=2109"}],"version-history":[{"count":2,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts\/2109\/revisions"}],"predecessor-version":[{"id":2145,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts\/2109\/revisions\/2145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/media\/2111"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/media?parent=2109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/categories?post=2109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/tags?post=2109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}