{"id":1478,"date":"2025-04-30T16:03:28","date_gmt":"2025-04-30T08:03:28","guid":{"rendered":"https:\/\/s3jnrqxbrg.onrocket.site\/?p=1478"},"modified":"2025-04-30T16:03:43","modified_gmt":"2025-04-30T08:03:43","slug":"%d9%85%d8%ad%d9%88%d9%84-%d8%a7%d9%84%d9%85%d8%b9%d8%af%d9%84-%d9%84%d8%aa%d8%b7%d8%a8%d9%8a%d9%82-%d8%a7%d9%84%d8%aa%d8%ad%d9%84%d9%8a%d9%84-%d8%a7%d9%84%d9%83%d9%87%d8%b1%d8%a8%d8%a7%d8%a6%d9%8a-2","status":"publish","type":"post","link":"https:\/\/tengyielectric.com\/ar\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/","title":{"rendered":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u0642\u0648\u0645 \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629"},"content":{"rendered":"<div class=\"gb-container gb-container-3e46977c\">\n<div class=\"gb-container gb-container-07fbd4be\">\n<div class=\"gb-container gb-container-dbe22cd8\">\n\n<h2 class=\"gb-headline gb-headline-15dcb0ac gb-headline-text\"><strong><strong><strong>\u0646\u0638\u0627\u0645 \u0645\u062d\u0648\u0644 \u0645\u0642\u0648\u0645 \u0645\u0642\u0648\u0645 700 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631\/15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629<\/strong><\/strong><\/strong><\/h2>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9ba03615\">\n<div class=\"gb-container gb-container-d8e45bca\">\n<div class=\"gb-container gb-container-06e5aada\">\n\n<h3 class=\"wp-block-heading\">\u062e\u0644\u0641\u064a\u0629 \u0627\u0644\u0645\u0634\u0631\u0648\u0639<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u062a\u0645 \u0646\u0634\u0631 \u062b\u0644\u0627\u062b\u0629 \u0623\u0646\u0638\u0645\u0629 \u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0642\u0648\u0645\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0644\u0645\u0635\u0646\u0639 \u0644\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0635\u0646\u0627\u0639\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 (DRC). \u0635\u064f\u0645\u0645\u062a \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0644\u062a\u0634\u063a\u064a\u0644 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629\u060c \u0648\u062a\u0636\u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0635\u064a\u0644 \u0637\u0627\u0642\u0629 \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0645\u0648\u062b\u0648\u0642 \u0628\u0647\u0627 \u0645\u0639 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062f\u0642\u064a\u0642 \u0641\u064a \u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u062a\u0633\u0627\u0642 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0648\u0643\u064a\u0645\u064a\u0627\u0626\u064a\u0629 \u0641\u064a \u0628\u064a\u0626\u0629 \u0635\u0639\u0628\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0645\u062d\u0648\u0644<\/strong>:: 700 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631\u060c \u062c\u0647\u062f \u0623\u0648\u0644\u064a 15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631<\/li>\n\n\n\n<li>\u200b<strong>\u0645\u062e\u0631\u062c \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/strong>: \u062c\u0647\u062f \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0642\u0627\u0628\u0644 \u0644\u0644\u062a\u0639\u062f\u064a\u0644 \u0645\u0646 0-56 \u0641\u0648\u0644\u062a\u060c \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 10 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u0644\u0643\u0644 \u0648\u062d\u062f\u0629.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/strong>: \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u0643\u0645\u064a\u0629<\/strong>: 3 \u0623\u0646\u0638\u0645\u0629 \u0643\u0627\u0645\u0644\u0629 (\u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0627\u0632\u064a).<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0642\u0648\u064a\u0645 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062c\u0647\u062f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u200b<strong>\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0635\u062d\u064a\u062d<\/strong>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u062a\u0635\u062d\u064a\u062d \u0627\u0644\u062b\u0627\u064a\u0631\u0633\u062a\u0648\u0631 (SCR) \u0628 12 \u0646\u0628\u0636\u0629<\/strong>: \u064a\u062a\u0645 \u062a\u062d\u0642\u064a\u0642\u0647 \u0645\u0646 \u062e\u0644\u0627\u0644 \u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u062c\u0633\u0631 \u0627\u0644\u0645\u0632\u062f\u0648\u062c \u0628\u0640 6 \u0646\u0628\u0636\u0627\u062a \u0645\u0639 \u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0645 \u062a\u063a\u064a\u064a\u0631 \u0637\u0648\u0631\u0647\u0627 (\u0625\u0632\u0627\u062d\u0629 30 \u062f\u0631\u062c\u0629)\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0644\u0644\u0645\u062f\u062e\u0644\u0627\u062a \u0648\u064a\u0639\u0632\u0632 \u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u0634\u0628\u0643\u0629.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u200b<strong>\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062c\u0647\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u200b<strong>\u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062e\u0634\u0646<\/strong>: \u0645\u063a\u064a\u0631 \u0627\u0644\u0635\u0646\u0628\u0648\u0631 \u0639\u0646\u062f \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (OLTC) \u0645\u062f\u0645\u062c \u0641\u064a \u0643\u0644 \u0645\u062d\u0648\u0644 \u0644\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u062f\u0631\u062c \u00b110%.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062f\u0642\u064a\u0642<\/strong>: \u064a\u062a\u064a\u062d \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0632\u0627\u0648\u064a\u0629 \u0637\u0648\u0631 \u0627\u0644\u062b\u0627\u064a\u0631\u0633\u062a\u0648\u0631 \u0636\u0628\u0637 \u062c\u0647\u062f \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0645\u0646 0% \u0625\u0644\u0649 100% \u0645\u0646\u00a0<em>\u064a\u0648\u062f\u0646<\/em>\u00a0(\u0627\u0644\u0646\u0627\u062a\u062c \u0627\u0644\u0645\u0642\u062f\u0631).<\/li>\n\n\n\n<li>\u200b<strong>\u062a\u062d\u0643\u0645 \u0643\u0627\u0645\u0644 \u0627\u0644\u0646\u0637\u0627\u0642<\/strong>: \u064a\u0648\u0641\u0631 \u0646\u0638\u0627\u0645\u0627 OLTC \u0648 SCR \u0627\u0644\u0645\u062f\u0645\u062c\u0627\u0646 \u0645\u0639\u064b\u0627 \u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0636\u0628\u0637 \u0627\u0644\u0625\u062e\u0631\u0627\u062c \u0628\u0633\u0644\u0627\u0633\u0629 0-100%\u060c \u0648\u0647\u0648 \u0645\u062b\u0627\u0644\u064a \u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062f\u064a\u0646\u0627\u0645\u064a\u0643\u064a\u0629.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u062a\u062e\u0641\u064a\u0641 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a<\/strong>: \u064a\u062d\u062f \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0645\u0643\u0648\u0646 \u0645\u0646 12 \u0646\u0628\u0636\u0629 \u0645\u0646 \u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a (THD) \u0625\u0644\u0649 &lt;10%\u060c \u0645\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 IEEE 519.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062f\u0642\u064a\u0642<\/strong>: \u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u0647\u062c\u064a\u0646 \u062b\u0628\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u00b1 0.75% \u0641\u064a \u0638\u0644 \u062a\u0642\u0644\u0628\u0627\u062a \u0627\u0644\u062d\u0645\u0644.<\/li>\n\n\n\n<li>\u200b<strong>\u0628\u0646\u0627\u0621 \u0645\u062a\u064a\u0646<\/strong>: \u062a\u062a\u0645\u064a\u0632 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u062e\u0627\u0635\u064a\u0629 \u0627\u0644\u0639\u0632\u0644 \u0645\u0646 \u0627\u0644\u0641\u0626\u0629 H \u0648\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0628\u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0642\u0633\u0631\u064a (FOA) \u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u0646\u0627\u062e \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 (\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u062a\u0635\u0644 \u0625\u0644\u0649 50 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629).<\/li>\n\n\n\n<li>\u200b<strong>\u0642\u0627\u0628\u0644\u064a\u0629 \u0627\u0644\u062a\u0648\u0633\u0639<\/strong>: \u064a\u0633\u0645\u062d \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0627\u0632\u064a \u0644\u062b\u0644\u0627\u062b \u0648\u062d\u062f\u0627\u062a \u0628\u062a\u0648\u0632\u064a\u0639 \u0645\u0631\u0646 \u0644\u0644\u0637\u0627\u0642\u0629 \u0639\u0628\u0631 \u062e\u0637\u0648\u0637 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u062a\u0639\u062f\u062f\u0629.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/strong>: \u062a\u0634\u0645\u0644 \u0627\u0644\u0636\u0645\u0627\u0646\u0627\u062a \u0645\u062a\u0639\u062f\u062f\u0629 \u0627\u0644\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f\u060c \u0648\u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u0627\u0626\u062f\u0629\u060c \u0648\u0627\u0644\u0643\u0634\u0641 \u0639\u0646 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0639\u0628\u0631 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 PLC.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u200b<strong>\u0643\u0641\u0627\u0621\u0629 \u0639\u0627\u0644\u064a\u0629<\/strong>: \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0646\u0638\u0627\u0645 \u226597.5% \u0639\u0646\u062f \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u0643\u0627\u0645\u0644\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0647\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629.<\/li>\n\n\n\n<li>\u200b<strong>\u0642\u062f\u0631\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u0643\u064a\u0641<\/strong>: \u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062c\u0647\u062f \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u062d\u0642\u064a\u0642\u064a \u064a\u0633\u062a\u0648\u0639\u0628 \u0638\u0631\u0648\u0641 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0644\u064a\u062a \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629 \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0625\u0646\u062a\u0627\u062c.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u062a\u0643\u0631\u0627\u0631<\/strong>: \u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0645\u0643\u0648\u0646 \u0645\u0646 \u062b\u0644\u0627\u062b \u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u062f\u0648\u0646 \u0627\u0646\u0642\u0637\u0627\u0639\u061b \u062d\u064a\u062b \u064a\u0645\u0643\u0646 \u0635\u064a\u0627\u0646\u0629 \u0648\u062d\u062f\u0629 \u0648\u0627\u062d\u062f\u0629 \u0628\u064a\u0646\u0645\u0627 \u062a\u062d\u0627\u0641\u0638 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0623\u062e\u0631\u0649 \u0639\u0644\u0649 \u0627\u0644\u0625\u0646\u062a\u0627\u062c.<\/li>\n\n\n\n<li>\u200b<strong>\u0627\u0644\u0645\u062a\u0627\u0646\u0629<\/strong>: \u062d\u0627\u0648\u064a\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062a\u0622\u0643\u0644 (\u062a\u0635\u0646\u064a\u0641 IP54) \u062a\u062d\u0645\u064a \u0645\u0646 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0633\u0627\u0626\u062f\u0629 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u062e\u0627\u062a\u0645\u0629<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u064a\u0648\u0641\u0631 \u0646\u0638\u0627\u0645 \u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u0642\u0648\u0645 \u0630\u0648 12 \u0646\u0628\u0636\u0629\u060c \u0627\u0644\u0630\u064a \u064a\u062c\u0645\u0639 \u0628\u064a\u0646 \u062a\u0642\u0646\u064a\u0627\u062a OLTC \u0648\u0627\u0644\u062b\u0627\u064a\u0631\u0633\u062a\u0648\u0631\u060c \u062d\u0644\u0627\u064b \u0642\u0648\u064a\u064b\u0627 \u0648\u0642\u0627\u0628\u0644\u064b\u0627 \u0644\u0644\u062a\u0637\u0648\u064a\u0631 \u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0644\u0635\u0646\u0627\u0639\u0629 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0645\u0631\u0643\u0632 \u062f\u0628\u064a \u0644\u0644\u0633\u0644\u0639 \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629. \u064a\u0639\u0645\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0645\u0643\u0648\u0646 \u0645\u0646 \u062b\u0644\u0627\u062b \u0648\u062d\u062f\u0627\u062a \u0639\u0644\u0649 \u062a\u0639\u0632\u064a\u0632 \u0627\u0644\u0645\u0631\u0648\u0646\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0648\u0627\u0644\u062a\u0643\u0631\u0627\u0631 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u0639\u0637\u064a \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0627\u0644\u0642\u0627\u0633\u064a\u0629. \u0648\u0645\u0646 \u062e\u0644\u0627\u0644 \u062f\u0645\u062c \u0643\u0628\u062d \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a\u0627\u062a \u0648\u0627\u0644\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062f\u0642\u064a\u0642 \u0648\u0627\u0644\u0645\u0631\u0648\u0646\u0629 \u0627\u0644\u0645\u0646\u0627\u062e\u064a\u0629\u060c \u064a\u0641\u064a \u0627\u0644\u0646\u0638\u0627\u0645 \u0628\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0635\u0646\u0627\u0639\u064a \u0648\u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0627\u0644\u0625\u0642\u0644\u064a\u0645\u064a\u0629.<\/p>\n\n\n<div class=\"gb-container gb-container-1247082c\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4d7feb70\">\n<div class=\"gb-grid-column gb-grid-column-9c7bc2ea\"><div class=\"gb-container gb-container-9c7bc2ea\">\n\n<figure class=\"gb-block-image gb-block-image-120ee56d\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"900\" class=\"gb-image gb-image-120ee56d\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0645\u0642\u0648\u0645 \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u06292\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp 600w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2-200x300.webp 200w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2-8x12.webp 8w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-8f7a2d85\"><div class=\"gb-container gb-container-8f7a2d85\">\n\n<figure class=\"gb-block-image gb-block-image-07a8220b\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"900\" class=\"gb-image gb-image-07a8220b\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo3.webp\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0645\u0642\u0648\u0645 \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u06293\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo3.webp 600w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo3-200x300.webp 200w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo3-8x12.webp 8w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-d28f2b6a\"><div class=\"gb-container gb-container-d28f2b6a\">\n\n<figure class=\"gb-block-image gb-block-image-d79a01bc\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"900\" class=\"gb-image gb-image-d79a01bc\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo1.webp\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0645\u0642\u0648\u0645 \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u06291\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo1.webp 600w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo1-200x300.webp 200w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo1-8x12.webp 8w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-822170f3\"><div class=\"gb-container gb-container-822170f3\">\n\n<figure class=\"gb-block-image gb-block-image-86dd6e53\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"900\" class=\"gb-image gb-image-86dd6e53\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo4.webp\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0645\u0642\u0648\u0645 \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u06294\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo4.webp 600w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo4-200x300.webp 200w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo4-8x12.webp 8w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b884af38\">\n<div class=\"gb-container gb-container-0d997913\">\n<div class=\"gb-container gb-container-12d6c45c\">\n<div class=\"gb-container gb-container-e4b92954\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-c263af85\">\n<div class=\"gb-grid-column gb-grid-column-be74dc72\"><div class=\"gb-container gb-container-be74dc72\">\n\n<p class=\"gb-headline gb-headline-a01f4858 gb-headline-text\">\u0646\u062d\u0646 \u0646\u0642\u062f\u0645 \u0623\u0641\u0636\u0644 \u0627\u0644\u062d\u0644\u0648\u0644 \u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a\u0643 \u0627\u0644\u0641\u0639\u0644\u064a\u0629.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-ffb4d65c gb-headline-text\">\u062a\u062d\u062f\u062b \u0625\u0644\u0649 \u062e\u0628\u0631\u0627\u0626\u0646\u0627 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u062d\u0644\u0648\u0644 \u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u0627\u064b \u0644\u0643.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-3726250d\"><div class=\"gb-container gb-container-3726250d\">\n<div class=\"gb-container gb-container-4f0d8dd7\">\n\n<a class=\"gb-button gb-button-7d9b861c gb-button-text\" href=\"#popmake-561\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u0646\u0638\u0627\u0645 \u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0642\u0648\u0645 700 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631\/15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 \u062e\u0644\u0641\u064a\u0629 \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u062a\u0645 \u0646\u0634\u0631 \u062b\u0644\u0627\u062b\u0629 \u0623\u0646\u0638\u0645\u0629 \u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0642\u0648\u0645 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0644\u0645\u0635\u0646\u0639 \u0644\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0635\u0646\u0627\u0639\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 (DRC). \u062a\u0645 \u062a\u0635\u0645\u064a\u0645\u0647\u0627 \u0644\u062a\u0634\u063a\u064a\u0644 ... <\/p>\n<p class=\"read-more-container\"><a title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u0642\u0648\u0645 \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/ar\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#more-1478\" aria-label=\"\u0627\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f \u0639\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u062b\u0628\u062a\u064a \u0644\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0643\u0647\u0631\u0648\u0627\u0644\u062a\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629\">\u0627\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f<\/a><\/p>","protected":false},"author":2,"featured_media":1483,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1478","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cases","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Rectifier Transformer for Electrolysis Application in DR Congo\u200b - Tengyi Electric<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rectifier Transformer for Electrolysis Application in DR Congo\u200b - Tengyi Electric\" \/>\n<meta property=\"og:description\" content=\"700kVA\/15kV Rectifier Transformer System for Electrolysis Application in DR Congo\u200b Project Background Three high-efficiency rectifier transformer systems were deployed for an industrial electrolysis plant in the Democratic Republic of the Congo (DRC). Designed to power ... \u0625\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-30T08:03:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-30T08:03:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"TYElectric\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"TYElectric\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/\"},\"author\":{\"name\":\"TYElectric\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\"},\"headline\":\"Rectifier Transformer for Electrolysis Application in DR Congo\u200b\",\"datePublished\":\"2025-04-30T08:03:28+00:00\",\"dateModified\":\"2025-04-30T08:03:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/\"},\"wordCount\":388,\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/rectifier-transformer-in-DR-Congo2.webp\",\"articleSection\":[\"Cases\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/\",\"name\":\"Rectifier Transformer for Electrolysis Application in DR Congo\u200b - Tengyi Electric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/rectifier-transformer-in-DR-Congo2.webp\",\"datePublished\":\"2025-04-30T08:03:28+00:00\",\"dateModified\":\"2025-04-30T08:03:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/rectifier-transformer-in-DR-Congo2.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/rectifier-transformer-in-DR-Congo2.webp\",\"width\":600,\"height\":900},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/rectifier-transformer-for-electrolysis-application-in-dr-congo\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Rectifier Transformer for Electrolysis Application in DR Congo\u200b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#website\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.webp\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/site14748-50v2xt.scloudsite101.com\\\/#\\\/schema\\\/person\\\/e71db6bec4b6acd349019abbb89ae896\",\"name\":\"TYElectric\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g\",\"caption\":\"TYElectric\"},\"url\":\"https:\\\/\\\/tengyielectric.com\\\/ar\\\/author\\\/tyelectric\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u0639\u062f\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 - Tengyi Electric","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/","og_locale":"ar_AR","og_type":"article","og_title":"Rectifier Transformer for Electrolysis Application in DR Congo\u200b - Tengyi Electric","og_description":"700kVA\/15kV Rectifier Transformer System for Electrolysis Application in DR Congo\u200b Project Background Three high-efficiency rectifier transformer systems were deployed for an industrial electrolysis plant in the Democratic Republic of the Congo (DRC). Designed to power ... \u0625\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f","og_url":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/","og_site_name":"Tengyi Electric","article_published_time":"2025-04-30T08:03:28+00:00","article_modified_time":"2025-04-30T08:03:43+00:00","og_image":[{"width":600,"height":900,"url":"https:\/\/site14748-50v2xt.scloudsite101.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.jpg","type":"image\/jpeg"}],"author":"TYElectric","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"TYElectric","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"3 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#article","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/"},"author":{"name":"TYElectric","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896"},"headline":"Rectifier Transformer for Electrolysis Application in DR Congo\u200b","datePublished":"2025-04-30T08:03:28+00:00","dateModified":"2025-04-30T08:03:43+00:00","mainEntityOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/"},"wordCount":388,"publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp","articleSection":["Cases"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/","name":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0645\u0639\u062f\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062c\u0645\u0647\u0648\u0631\u064a\u0629 \u0627\u0644\u0643\u0648\u0646\u063a\u0648 \u0627\u0644\u062f\u064a\u0645\u0642\u0631\u0627\u0637\u064a\u0629 - Tengyi Electric","isPartOf":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#primaryimage"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp","datePublished":"2025-04-30T08:03:28+00:00","dateModified":"2025-04-30T08:03:43+00:00","breadcrumb":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/04\/rectifier-transformer-in-DR-Congo2.webp","width":600,"height":900},{"@type":"BreadcrumbList","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/rectifier-transformer-for-electrolysis-application-in-dr-congo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/site14748-50v2xt.scloudsite101.com\/"},{"@type":"ListItem","position":2,"name":"Rectifier Transformer for Electrolysis Application in DR Congo\u200b"}]},{"@type":"WebSite","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#website","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","description":"\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0631\u0627\u0626\u062f\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a","publisher":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/site14748-50v2xt.scloudsite101.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#organization","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","url":"https:\/\/site14748-50v2xt.scloudsite101.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.webp","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/site14748-50v2xt.scloudsite101.com\/#\/schema\/person\/e71db6bec4b6acd349019abbb89ae896","name":"TYElectric","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75a9c2c93ad2f4499bee290483e8bd7d60eb9539d836a2748f1d0ca7102542d8?s=96&r=g","caption":"TYElectric"},"url":"https:\/\/tengyielectric.com\/ar\/author\/tyelectric\/"}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts\/1478","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/comments?post=1478"}],"version-history":[{"count":0,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/posts\/1478\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/media\/1483"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/media?parent=1478"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/categories?post=1478"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/tags?post=1478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}