{"id":912,"date":"2025-01-17T14:19:35","date_gmt":"2025-01-17T06:19:35","guid":{"rendered":"https:\/\/s3jnrqxbrg.onrocket.site\/?page_id=912"},"modified":"2025-07-09T18:25:39","modified_gmt":"2025-07-09T10:25:39","slug":"%d9%85%d8%ad%d9%88%d9%84-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-srkwwdc","status":"publish","type":"page","link":"https:\/\/tengyielectric.com\/ar\/power-transformer-srkwdc\/","title":{"rendered":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 SRKWDC"},"content":{"rendered":"<div class=\"gb-container gb-container-f2d0df70\">\n<div class=\"gb-container gb-container-87b37709\">\n<div class=\"gb-container gb-container-f70d84af\">\n\n<h1 class=\"gb-headline gb-headline-c3ead352 gb-headline-text\">\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629<\/h1>\n\n\n\n<p class=\"gb-headline gb-headline-1c44214b gb-headline-text\">\u062a\u0642\u062f\u064a\u0645 \u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0628\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062c\u0647\u062f \u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u062a\u0644\u0628\u064a\u0629 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0634\u0628\u0643\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0648\u0637\u0646\u064a\u0629 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0648\u062a\u0642\u062f\u064a\u0645 \u062e\u062f\u0645\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9bedf81d\">\n<div class=\"gb-container gb-container-e46be8ee\">\n<div class=\"gb-container gb-container-b23703f4\">\n<div class=\"gb-container gb-container-66b9cb03\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-eaf06577\">\n<div class=\"gb-grid-column gb-grid-column-93eece37\"><div class=\"gb-container gb-container-93eece37\">\n<div class=\"gb-container gb-container-f69fb4aa\">\n\n\t\t<!-- MasterSlider -->\n\t\t<div id=\"P_MS6a00acb7dc17e\" class=\"master-slider-parent msl ms-parent-id-4\" style=\"max-width:800px;\">\n\n\t\t\t\n\t\t\t<!-- MasterSlider Main -->\n\t\t\t<div id=\"MS6a00acb7dc17e\" class=\"master-slider ms-skin-default\" >\n\t\t\t\t \t\t\t\t \n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-sale.png\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-sale-140x80.png\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail7.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail7-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail1.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail1-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail2.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail2-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail3.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail3-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail4.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail4-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail5.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail5-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail6.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail6-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div  class=\"ms-slide\" data-delay=\"3\" data-fill-mode=\"fill\"  >\n\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/tengyielectric.com\/wp-content\/plugins\/master-slider\/public\/assets\/css\/blank.gif\" alt=\"\" title=\"\" data-src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail8.jpg\" \/>\n\n\n\t<img decoding=\"async\" class=\"ms-thumb\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-detail8-140x80.jpg\" alt=\"\" \/>\n\t<div class=\"ms-thumb\" ><div class=\"ms-tab-context\"><div class=\"&quot;ms-tab-context&quot;\"><\/div><\/div>\n<\/div>\n\t\t\t\t<\/div>\n\n\t\t\t<\/div>\n\t\t\t<!-- END MasterSlider Main -->\n\n\t\t\t \n\t\t<\/div>\n\t\t<!-- END MasterSlider -->\n\n\t\t<script>\n\t\t(function ( $ ) {\n\t\t\t\"use strict\";\n\n\t\t\t$(function () {\n\t\t\t\tvar masterslider_c17e = new MasterSlider();\n\n\t\t\t\t\/\/ slider controls\n\t\t\t\tmasterslider_c17e.control('arrows'     ,{ autohide:false, overVideo:true  });\t\t\t\tmasterslider_c17e.control('bullets'    ,{ autohide:false, overVideo:true, dir:'h', align:'bottom' , margin:10  });\n\n\t\t\t\tmasterslider_c17e.control('thumblist'  ,{ autohide:false, overVideo:true, dir:'h', speed:17, inset:false, arrows:false, hover:false, customClass:'', align:'bottom',type:'thumbs', margin:5, width:140, height:80, space:5, fillMode:'fill'  });\n\t\t\t\t\/\/ slider setup\n\t\t\t\tmasterslider_c17e.setup(\"MS6a00acb7dc17e\", {\n\t\t\t\t\t\twidth           : 650,\n\t\t\t\t\t\theight          : 630,\n\t\t\t\t\t\tminHeight       : 0,\n\t\t\t\t\t\tspace           : 0,\n\t\t\t\t\t\tstart           : 1,\n\t\t\t\t\t\tgrabCursor      : true,\n\t\t\t\t\t\tswipe           : true,\n\t\t\t\t\t\tmouse           : true,\n\t\t\t\t\t\tlayout          : \"boxed\",\n\t\t\t\t\t\twheel           : false,\n\t\t\t\t\t\tautoplay        : true,\n\t\t\t\t\t\tinstantStartLayers:false,\n\t\t\t\t\t\tloop            : true,\n\t\t\t\t\t\tshuffle         : false,\n\t\t\t\t\t\tpreload         : 0,\n\t\t\t\t\t\theightLimit     : true,\n\t\t\t\t\t\tautoHeight      : false,\n\t\t\t\t\t\tsmoothHeight    : true,\n\t\t\t\t\t\tendPause        : false,\n\t\t\t\t\t\toverPause       : true,\n\t\t\t\t\t\tfillMode        : \"fill\",\n\t\t\t\t\t\tcenterControls  : true,\n\t\t\t\t\t\tstartOnAppear   : false,\n\t\t\t\t\t\tlayersMode      : \"center\",\n\t\t\t\t\t\thideLayers      : false,\n\t\t\t\t\t\tfullscreenMargin: 0,\n\t\t\t\t\t\tspeed           : 20,\n\t\t\t\t\t\tdir             : \"h\",\n\t\t\t\t\t\tparallaxMode    : 'swipe',\n\t\t\t\t\t\tview            : \"basic\"\n\t\t\t\t});\n\n\t\t\t\t\n\t\t\t\twindow.masterslider_instances = window.masterslider_instances || [];\n\t\t\t\twindow.masterslider_instances.push( masterslider_c17e );\n\t\t\t });\n\n\t\t})(jQuery);\n\t\t<\/script>\n\n\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb3dfde6\"><div class=\"gb-container gb-container-eb3dfde6\">\n<div class=\"gb-container gb-container-4e1a0988\">\n\n<h2 class=\"gb-headline gb-headline-7258d199 gb-headline-text\">\u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 \u0644\u0644\u0628\u064a\u0639<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-2e34a941 gb-headline-text\">\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 Tengyi \u0645\u0648\u062b\u0648\u0642\u0629 \u0648\u0641\u0639\u0627\u0644\u0629 \u0648\u0645\u0635\u0645\u0645\u0629 \u0644\u062a\u062d\u0642\u064a\u0642 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0623\u0645\u062b\u0644. \u0645\u062b\u0627\u0644\u064a \u0644\u0645\u062d\u0637\u0627\u062a \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0648\u0627\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0648\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0628\u062a\u0631\u0648\u0643\u064a\u0645\u0627\u0648\u064a\u0627\u062a. \u064a\u0636\u0645\u0646 \u0623\u062f\u0627\u0621\u064b \u0645\u0648\u062b\u0648\u0642\u064b\u0627 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0627\u0644\u0634\u0628\u0643\u064a\u0629.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d8ebb883 gb-headline-text\">\u0627\u0644\u0645\u0639\u0644\u0645\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-27ca91ab\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0637\u0627\u0642\u0629:<\/strong> 6.3-240MVA<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-012f0c5f\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0623\u0633\u0627\u0633\u064a: <\/strong>66 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u061b 110 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u061b 220 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u061b \u062a\u062e\u0635\u064a\u0635<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be479e67\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u062b\u0627\u0646\u0648\u064a: <\/strong>6.3 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a - 69 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u061b \u062a\u062e\u0635\u064a\u0635<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-838d3be8 gb-headline-text\">\u0638\u0631\u0648\u0641 \u0627\u0644\u0639\u0645\u0644<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-cca7f3b7\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 1000 \u0645\u062a\u0631.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9a54171d\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0631\u0627\u0648\u062d \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0628\u064a\u0646 -25 \u2103 \u0648+40 \u2103.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-05779465\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u064a\u062c\u0628 \u0623\u0644\u0627 \u062a\u062a\u062c\u0627\u0648\u0632 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0646\u0633\u0628\u064a\u0629 90% (+25 \u2103).<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-56dd8c24\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0644\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0627\u0644\u0645\u064a\u0644 \u0627\u0644\u0631\u0623\u0633\u064a 5 \u062f\u0631\u062c\u0627\u062a.<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-0bacef22\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0644\u0627 \u062a\u062a\u062c\u0627\u0648\u0632 \u0633\u0631\u0639\u0629 \u0627\u0644\u0631\u064a\u0627\u062d \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 35 \u0645\/\u062b\u0627\u0646\u064a\u0629.<\/span><\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-bf2c2659\">\n\n<a class=\"gb-button gb-button-67c92043 gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-92e0c466\">\n<div class=\"gb-container gb-container-018f91a0\">\n<div class=\"gb-container gb-container-d0d4194c\">\n\n<h2 class=\"gb-headline gb-headline-72c1a7bd gb-headline-text\">\u0645\u0632\u0627\u064a\u0627 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 Tengyi<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-333d9159 gb-headline-text\">\u064a\u0648\u0641\u0631 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a \u0645\u0646 Tengyi \u062a\u062d\u0648\u064a\u0644\u064b\u0627 \u0641\u0639\u0627\u0644\u064b\u0627 \u0644\u0644\u062c\u0647\u062f\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u062a\u0648\u0632\u064a\u0639\u064b\u0627 \u0645\u0648\u062b\u0648\u0642\u064b\u0627 \u0644\u0644\u0637\u0627\u0642\u0629 \u0639\u0628\u0631 \u0645\u062e\u062a\u0644\u0641 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a. \u064a\u0639\u0632\u0632 \u062a\u0635\u0645\u064a\u0645\u0647 \u0627\u0644\u0642\u0648\u064a \u0645\u0646 \u0627\u0644\u0645\u062a\u0627\u0646\u0629 \u0648\u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629. \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0630\u0644\u0643\u060c \u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0645\u062d\u0648\u0644 \u0644\u062a\u062d\u0642\u064a\u0642 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0645\u0646\u0627\u0633\u0628\u064b\u0627 \u0644\u0643\u0644 \u0645\u0646 \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u062d\u0636\u0631\u064a\u0629 \u0648\u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629.<\/p>\n\n\n<div class=\"gb-container gb-container-8645fb41\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-096ad6d8\">\n<div class=\"gb-grid-column gb-grid-column-a5ad70ad\"><div class=\"gb-container gb-container-a5ad70ad\">\n<div class=\"gb-container gb-container-394eaaa3 box-shadow\">\n<div class=\"gb-container gb-container-107c6b9e\">\n\n<h3 class=\"gb-headline gb-headline-c8d655c4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0636\u0648\u0636\u0627\u0621 \u0645\u0646\u062e\u0641\u0636\u0629<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-e9b2e4ab gb-headline-text\">\u062a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u062a\u0644\u0648\u062b \u0627\u0644\u0636\u0648\u0636\u0627\u0626\u064a \u0627\u0644\u0628\u064a\u0626\u064a\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u062a\u0634\u063a\u064a\u0644\u064b\u0627 \u0623\u0643\u062b\u0631 \u0647\u062f\u0648\u0621\u064b\u0627 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u062d\u0636\u0631\u064a\u0629 \u0648\u0627\u0644\u0633\u0643\u0646\u064a\u0629. \u062a\u0639\u0632\u0632 \u0647\u0630\u0647 \u0627\u0644\u0645\u064a\u0632\u0629 \u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u062c\u062a\u0645\u0639 \u0648\u062a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u0625\u0632\u0639\u0627\u062c \u0627\u0644\u0645\u0631\u062a\u0628\u0637 \u0628\u0627\u0644\u0636\u0648\u0636\u0627\u0621.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-eb4ce9ec\"><div class=\"gb-container gb-container-eb4ce9ec\">\n<div class=\"gb-container gb-container-369e45f4 box-shadow\">\n<div class=\"gb-container gb-container-825a954d\">\n\n<h3 class=\"gb-headline gb-headline-8f6f5716\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-a6ec4c2c gb-headline-text\">\u064a\u0648\u0641\u0631 \u0642\u062f\u0631\u0629 \u0642\u0648\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u0632\u0627\u0626\u062f\u060c \u0645\u0645\u0627 \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u062d\u062a\u0649 \u0641\u064a \u0638\u0644 \u0627\u0644\u0637\u0644\u0628 \u0627\u0644\u0639\u0627\u0644\u064a. \u062a\u0633\u0627\u0639\u062f \u0647\u0630\u0647 \u0627\u0644\u0645\u064a\u0632\u0629 \u0641\u064a \u0645\u0646\u0639 \u0627\u0644\u0633\u062e\u0648\u0646\u0629 \u0627\u0644\u0632\u0627\u0626\u062f\u0629 \u0648\u0625\u0637\u0627\u0644\u0629 \u0639\u0645\u0631 \u062e\u062f\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-848ab375\"><div class=\"gb-container gb-container-848ab375\">\n<div class=\"gb-container gb-container-2b0a1ce0 box-shadow\">\n<div class=\"gb-container gb-container-d9a5bba3\">\n\n<h3 class=\"gb-headline gb-headline-2d8a461e\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>\u0641\u0642\u062f\u0627\u0646 \u0637\u0627\u0642\u0629 \u0645\u0646\u062e\u0641\u0636\u0629<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-866cce29 gb-headline-text\">\u064a\u062d\u0633\u0651\u0646 \u0647\u064a\u0643\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u0642\u0644\u064a\u0644 \u0641\u0642\u062f \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u062a\u062d\u0633\u064a\u0646 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0648\u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u062a\u0643\u0627\u0644\u064a\u0641. \u0648\u0647\u0630\u0627 \u064a\u0633\u0627\u0647\u0645 \u0641\u064a \u0646\u0638\u0627\u0645 \u062a\u0648\u0632\u064a\u0639 \u0637\u0627\u0642\u0629 \u0623\u0643\u062b\u0631 \u0627\u0633\u062a\u062f\u0627\u0645\u0629 \u0648\u0627\u0642\u062a\u0635\u0627\u062f\u064a\u0629.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-28d68822\"><div class=\"gb-container gb-container-28d68822\">\n<div class=\"gb-container gb-container-c184f74c box-shadow\">\n<div class=\"gb-container gb-container-8d33aa0c\">\n\n<h3 class=\"gb-headline gb-headline-3e36ab2b\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-703d9ad4 gb-headline-text\">\u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0642\u0631 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642 \u0628\u0647 \u0645\u0646 \u062e\u0644\u0627\u0644 \u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0645\u0645\u0627 \u064a\u0637\u064a\u0644 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u064a\u0639\u0632\u0632 \u0627\u0644\u0623\u062f\u0627\u0621 \u0641\u064a \u0638\u0644 \u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d4594f3\"><div class=\"gb-container gb-container-6d4594f3\">\n<div class=\"gb-container gb-container-86db63c4 box-shadow\">\n<div class=\"gb-container gb-container-9d0a8965\">\n\n<h3 class=\"gb-headline gb-headline-40be9ad4\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong><strong>\u062a\u0635\u0645\u064a\u0645 \u0628\u062f\u0648\u0646 \u062a\u0633\u0631\u0628<\/strong><\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-d30e367f gb-headline-text\">\u064a\u0648\u0641\u0631 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 Tengyi \u0623\u062f\u0627\u0621\u064b \u0639\u0627\u0644\u064a\u064b\u0627 \u0641\u064a \u0645\u0646\u0639 \u062a\u0633\u0631\u0628 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0633\u0627\u0626\u0644 \u0627\u0644\u062a\u0628\u0631\u064a\u062f. \u0648\u0647\u0630\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0648\u064a\u0642\u0644\u0644 \u0645\u0646 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u062a\u0644\u0648\u062b\u060c \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-f6923e84\"><div class=\"gb-container gb-container-f6923e84\">\n<div class=\"gb-container gb-container-d33107a7 box-shadow\">\n<div class=\"gb-container gb-container-eb8fa6f4\">\n\n<h3 class=\"gb-headline gb-headline-42815d27\"><span class=\"gb-icon\"><svg height=\"200\" width=\"200\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" viewbox=\"0 0 1024 1024\" class=\"icon\"><path d=\"M652.8 264.32c-41.6-39.04-96-58.88-153.6-55.04-104.32 6.4-188.8 93.44-192 197.76-2.56 69.12 30.08 134.4 86.4 174.08 1.92 3.2 10.24 17.92 34.56 78.08 7.04 17.92 24.32 29.44 44.16 29.44 0 0 0 0 0 0l80.64 0c19.2 0 36.48-11.52 44.16-29.44 24.96-61.44 33.28-75.52 35.2-78.72 53.76-38.4 85.76-101.12 85.76-167.04C717.44 357.76 693.76 303.36 652.8 264.32zM611.84 556.16c-4.48 3.2-10.88 7.68-45.44 92.16-2.56 5.76-7.68 9.6-14.08 9.6l-80.64 0c0 0 0 0 0 0-6.4 0-12.16-3.84-14.08-9.6-33.92-83.84-40.32-88.32-44.8-91.52C364.8 522.88 337.28 467.2 339.2 408.32c3.2-88.32 74.24-161.92 161.92-167.04 3.84 0 7.68-0.64 10.88-0.64 44.16 0 86.4 16.64 118.4 46.72 35.2 33.28 54.4 78.08 54.4 126.08C685.44 470.4 657.92 523.52 611.84 556.16z\"><\/path><path d=\"M583.68 695.68l-142.72 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l142.72 0c8.96 0 16-7.04 16-16S592.64 695.68 583.68 695.68z\"><\/path><path d=\"M576.64 734.08l-129.28 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l129.28 0c8.96 0 16-7.04 16-16S585.6 734.08 576.64 734.08z\"><\/path><path d=\"M552.32 771.84l-80.64 0c-8.96 0-16 7.04-16 16s7.04 16 16 16l80.64 0c8.96 0 16-7.04 16-16S561.28 771.84 552.32 771.84z\"><\/path><path d=\"M484.48 307.2c-47.36 10.88-83.84 48-93.44 95.36-1.92 8.96 3.84 17.28 12.16 19.2 1.28 0 1.92 0.64 3.2 0.64 7.68 0 14.08-5.12 15.36-12.8 7.04-35.2 34.56-62.72 69.12-70.4 8.32-1.92 14.08-10.24 12.16-19.2S493.44 305.28 484.48 307.2z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\"><strong><strong>\u062a\u0634\u063a\u064a\u0644 \u0628\u062f\u0648\u0646 \u0635\u064a\u0627\u0646\u0629<\/strong><\/strong><\/span><\/h3>\n\n\n\n<p class=\"gb-headline gb-headline-1ef1ca4a gb-headline-text\">\u064a\u0642\u0644\u0644 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0644\u0644\u0639\u0645\u0644\u0627\u0621 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0625\u0644\u063a\u0627\u0621 \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629. \u062a\u0636\u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0645\u064a\u0632\u0629 \u0623\u062f\u0627\u0621\u064b \u062b\u0627\u0628\u062a\u064b\u0627 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u062b\u0627\u0628\u062a\u0629 \u0628\u0623\u0642\u0644 \u0642\u062f\u0631 \u0645\u0646 \u0627\u0644\u062a\u062f\u062e\u0644.<\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f9e68e6b\">\n\n<a class=\"gb-button gb-button-ef0351a3 gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-6fcd151c\">\n<div class=\"gb-container gb-container-6e3ddcdc\">\n<div class=\"gb-container gb-container-8dc4b63d\">\n\n<h2 class=\"gb-headline gb-headline-acf3b302 gb-headline-text\">\u062a\u0635\u0645\u064a\u0645 \u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 110 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 25000 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631<\/h2>\n\n\n\n<figure class=\"gb-block-image gb-block-image-e03afde8\"><img decoding=\"async\" width=\"2456\" height=\"1686\" class=\"gb-image gb-image-e03afde8\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg\" alt=\"\" title=\"\u062a\u0635\u0645\u064a\u0645 \u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 110 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a 110 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg 2456w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-300x206.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-1024x703.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-768x527.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-1536x1054.jpg 1536w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design-2048x1406.jpg 2048w\" sizes=\"(max-width: 2456px) 100vw, 2456px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-3c2e491a\">\n\n<h3 class=\"gb-headline gb-headline-a31cd1ee gb-headline-text\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u064a \u0627\u0644\u0644\u0641 \u0627\u0644\u0645\u0632\u062f\u0648\u062c \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0630\u0648 \u0627\u0644\u0644\u0641 \u0627\u0644\u0645\u0632\u062f\u0648\u062c \u0639\u0644\u0649 \u0627\u0644\u062d\u0645\u0644<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631)<\/td><td colspan=\"2\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/td><td rowspan=\"2\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td rowspan=\"2\">\u062e\u0633\u0627\u0631\u0629 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td rowspan=\"2\">75 \u2103 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \uff08kw1)<\/td><td rowspan=\"2\">\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td rowspan=\"2\">\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (%)<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><\/tr><tr><td>6300<\/td><td rowspan=\"11\">110 \u00b1 8 * 1.25%<\/td><td rowspan=\"11\">6.3<br>6.6<br>10.5<br>11<\/td><td rowspan=\"11\">YNd11<\/td><td>10<\/td><td>36<\/td><td>0.8<\/td><td rowspan=\"11\">10.5<\/td><\/tr><tr><td>8000<\/td><td>12<\/td><td>45<\/td><td>0.8<\/td><\/tr><tr><td>10000<\/td><td>14.2<\/td><td>53<\/td><td>0.74<\/td><\/tr><tr><td>12500<\/td><td>16.8<\/td><td>63<\/td><td>0.74<\/td><\/tr><tr><td>16000<\/td><td>20.2<\/td><td>77<\/td><td>0.69<\/td><\/tr><tr><td>20000<\/td><td>24<\/td><td>93<\/td><td>0.69<\/td><\/tr><tr><td>25000<\/td><td>28.4<\/td><td>110<\/td><td>0.64<\/td><\/tr><tr><td>31500<\/td><td>33.8<\/td><td>133<\/td><td>0.64<\/td><\/tr><tr><td>40000<\/td><td>40.4<\/td><td>156<\/td><td>0.58<\/td><\/tr><tr><td>50000<\/td><td>47.8<\/td><td>194<\/td><td>0.58<\/td><\/tr><tr><td>63000<\/td><td>56.8<\/td><td>234<\/td><td>0.52<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-140ded7c\">\n\n<a class=\"gb-button gb-button-09555e88 gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-5e2f8db3\">\n\n<h3 class=\"gb-headline gb-headline-0a1cceb9 gb-headline-text\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a \u0639\u0644\u0649 \u0645\u063a\u064a\u0631 \u0627\u0644\u062a\u062d\u0645\u064a\u0644<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631)<\/td><td colspan=\"3\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/td><td rowspan=\"2\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td rowspan=\"2\">\u062e\u0633\u0627\u0631\u0629 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td rowspan=\"2\">75 \u2103 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \uff08kw1)<\/td><td rowspan=\"2\">\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td rowspan=\"2\">\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (%)<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><\/tr><tr><td>6300<\/td><td rowspan=\"11\">110 \u00b1 8 * 1.25%<\/td><td rowspan=\"11\">35<br>37<br>38.5<\/td><td rowspan=\"11\">6.3<br>6.6<br>10.5<br>11<\/td><td rowspan=\"11\">\u064a\u0646\u064a\u06460\u062f11<\/td><td>12<\/td><td>47<\/td><td>0.95<\/td><td rowspan=\"11\">10.5<br>17.5-18.5<br>6.5<\/td><\/tr><tr><td>8000<\/td><td>14.4<\/td><td>56<\/td><td>0.95<\/td><\/tr><tr><td>10000<\/td><td>17.1<\/td><td>66<\/td><td>0.89<\/td><\/tr><tr><td>12500<\/td><td>20.2<\/td><td>78<\/td><td>0.89<\/td><\/tr><tr><td>16000<\/td><td>24.2<\/td><td>95<\/td><td>0.84<\/td><\/tr><tr><td>20000<\/td><td>28.6<\/td><td>112<\/td><td>0.84<\/td><\/tr><tr><td>25000<\/td><td>33.8<\/td><td>133<\/td><td>0.78<\/td><\/tr><tr><td>31500<\/td><td>40.2<\/td><td>157<\/td><td>0.78<\/td><\/tr><tr><td>40000<\/td><td>48.2<\/td><td>189<\/td><td>0.73<\/td><\/tr><tr><td>50000<\/td><td>56.9<\/td><td>225<\/td><td>0.73<\/td><\/tr><tr><td>63000<\/td><td>67.7<\/td><td>270<\/td><td>0.67<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-6420c3b8\">\n\n<a class=\"gb-button gb-button-c10e0170 gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9f4b17f0\">\n\n<h3 class=\"gb-headline gb-headline-a06e7ecf gb-headline-text\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062b\u064a\u0631 \u063a\u064a\u0631 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0644\u0645\u063a\u064a\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u0627\u062a\u064a \u0627\u0644\u0627\u0642\u062a\u0631\u0627\u0646<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631)<\/td><td colspan=\"3\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/td><td rowspan=\"2\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td colspan=\"3\">\u062a\u0631\u0643\u064a\u0628\u0629 \u0627\u0644\u062a\u0635\u0639\u064a\u062f<\/td><td colspan=\"3\">\u0627\u0644\u062c\u0645\u0639 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a<\/td><td colspan=\"2\">\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (%)<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0639\u062f\u0645 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td>\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td>\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td>\u0639\u062f\u0645 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td>\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td>\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td>\u062a\u0635\u0639\u064a\u062f<\/td><td>\u0627\u0644\u062a\u0646\u062d\u064a<\/td><\/tr><tr><td>31500<\/td><td rowspan=\"9\">220 \u00b1 2*2*2.5%<br><br>242 \u00b1 2 * 2.5%<\/td><td rowspan=\"9\">115<br>121<\/td><td rowspan=\"5\">6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">YNa0d11<\/td><td>25<\/td><td>117<\/td><td>0.57<\/td><td>22<\/td><td>99<\/td><td>0.5<\/td><td rowspan=\"9\">12-14<br>8-12<br>14-18<\/td><td rowspan=\"9\">8-10<br>28-34<br>18-24<\/td><\/tr><tr><td>40000<\/td><td>29<\/td><td>144<\/td><td>0.57<\/td><td>26<\/td><td>121<\/td><td>0.5<\/td><\/tr><tr><td>50000<\/td><td>34<\/td><td>170<\/td><td>0.5<\/td><td>30<\/td><td>144<\/td><td>0.43<\/td><\/tr><tr><td>63000<\/td><td>40<\/td><td>201<\/td><td>0.5<\/td><td>36<\/td><td>171<\/td><td>0.43<\/td><\/tr><tr><td>90000<\/td><td>50<\/td><td>276<\/td><td>0.43<\/td><td>46<\/td><td>234<\/td><td>0.36<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"4\">10.5<br>11<br>13.8<br>15.75<br>18<br>35<br>37<br>38.5<\/td><td>62<\/td><td>340<\/td><td>0.43<\/td><td>56<\/td><td>288<\/td><td>0.6<\/td><\/tr><tr><td>150000<\/td><td>73<\/td><td>405<\/td><td>0.36<\/td><td>66<\/td><td>342<\/td><td>0.33<\/td><\/tr><tr><td>180000<\/td><td>84<\/td><td>463<\/td><td>0.36<\/td><td>76<\/td><td>387<\/td><td>0.33<\/td><\/tr><tr><td>240000<\/td><td>99<\/td><td>595<\/td><td>0.33<\/td><td>89<\/td><td>504<\/td><td>0.25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-890e4cf9\">\n\n<a class=\"gb-button gb-button-bb8393dd gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b3be7210\">\n\n<h3 class=\"gb-headline gb-headline-db8254d3 gb-headline-text\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u064a \u0627\u0644\u0644\u0641 \u0627\u0644\u0645\u0632\u062f\u0648\u062c \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0630\u0648 \u0627\u0644\u0644\u0641 \u0627\u0644\u0645\u0632\u062f\u0648\u062c \u0639\u0644\u0649 \u0627\u0644\u062d\u0645\u0644<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631)<\/td><td colspan=\"2\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/td><td rowspan=\"2\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td rowspan=\"2\">\u062e\u0633\u0627\u0631\u0629 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td rowspan=\"2\">75 \u2103 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \uff08kw1)<\/td><td rowspan=\"2\">\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td rowspan=\"2\">\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (%)<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><\/tr><tr><td>31500<\/td><td rowspan=\"11\">220 \u00b1 8 * 1.25%<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"11\">YNa0d11<\/td><td>38<\/td><td>135<\/td><td>0.7<\/td><td rowspan=\"11\">12-14<\/td><\/tr><tr><td>40000<\/td><td>45<\/td><td>157<\/td><td>0.63<\/td><\/tr><tr><td>50000<\/td><td>54<\/td><td>189<\/td><td>0.56<\/td><\/tr><tr><td>63000<\/td><td>63<\/td><td>220<\/td><td>0.56<\/td><\/tr><tr><td>90000<\/td><td>80<\/td><td>288<\/td><td>0.49<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"3\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>99<\/td><td>346<\/td><td>0.49<\/td><\/tr><tr><td>150000<\/td><td>116<\/td><td>405<\/td><td>0.42<\/td><\/tr><tr><td>180000<\/td><td>135<\/td><td>468<\/td><td>0.42<\/td><\/tr><tr><td>120000<\/td><td rowspan=\"3\">66<br>69<\/td><td>102<\/td><td>355<\/td><td>0.49<\/td><\/tr><tr><td>150000<\/td><td>120<\/td><td>415<\/td><td>0.42<\/td><\/tr><tr><td>180000<\/td><td>140<\/td><td>475<\/td><td>0.42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-78b00c6a\">\n\n<a class=\"gb-button gb-button-d6a84abd gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-adb0fa00\">\n\n<h3 class=\"gb-headline gb-headline-2e79366d gb-headline-text\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"10\"><strong>\u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0645\u063a\u064a\u0631<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">\u0627\u0644\u0633\u0639\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631)<\/td><td colspan=\"3\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/td><td rowspan=\"2\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a<\/td><td rowspan=\"2\">\u062e\u0633\u0627\u0631\u0629 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (\u0643\u064a\u0644\u0648\u0648\u0627\u0637)<\/td><td rowspan=\"2\">75 \u2103 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \uff08kw1)<\/td><td rowspan=\"2\">\u062a\u064a\u0627\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 (%)<\/td><td rowspan=\"2\">\u062a\u0639\u064a\u064a\u0646 \u0627\u0644\u0633\u0639\u0629 (%)<\/td><td rowspan=\"2\">\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (%)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">31500<\/td><td rowspan=\"9\">220 \u00b1 8 * 1.25%<\/td><td rowspan=\"9\">69<br>115<br>121<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">\u064a\u0646\u064a\u06460\u062f11<\/td><td>44<\/td><td>162<\/td><td>0.77<\/td><td rowspan=\"9\">100\/100\/100<br>100\/50\/100<br>100\/100\/50<\/td><td rowspan=\"9\">12-14<br>22-24<br>7-9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40000<\/td><td>52<\/td><td>189<\/td><td>0.7<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">50000<\/td><td>60<\/td><td>225<\/td><td>0.63<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">63000<\/td><td>70<\/td><td>261<\/td><td>0.63<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">90000<\/td><td>92<\/td><td>351<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">120000<\/td><td rowspan=\"4\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>115<\/td><td>432<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150000<\/td><td>135<\/td><td>513<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">180000<\/td><td>156<\/td><td>630<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">240000<\/td><td>193<\/td><td>780<\/td><td>0.45<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"10\"><strong>\u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0644\u0641\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0645\u063a\u064a\u0631 \u0643\u0644\u0645\u0629 \u0627\u0642\u062a\u0631\u0627\u0646 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">31500<\/td><td rowspan=\"9\">220 \u00b1 8 * 1.25%<\/td><td rowspan=\"9\">115<br>121<\/td><td rowspan=\"5\">6.3<br>6.6<br>10.5<br>11<br>35<br>37<br>38.5<\/td><td rowspan=\"9\">YNa0d11<\/td><td>25<\/td><td>108<\/td><td>0.56<\/td><td rowspan=\"9\">100\/100\/50<\/td><td rowspan=\"9\">8-10<br>28-34<br>18-24<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40000<\/td><td>30<\/td><td>132<\/td><td>0.56<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">50000<\/td><td>36<\/td><td>157<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">63000<\/td><td>42<\/td><td>189<\/td><td>0.49<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">90000<\/td><td>51<\/td><td>247<\/td><td>0.42<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">120000<\/td><td rowspan=\"4\">10.5<br>11<br>35<br>37<br>38.5<\/td><td>64<\/td><td>307<\/td><td>0.42<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150000<\/td><td>76<\/td><td>365<\/td><td>0.35<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">180000<\/td><td>85<\/td><td>419<\/td><td>0.35<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">240000<\/td><td>104<\/td><td>540<\/td><td>0.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"gb-container gb-container-ffefec8e\">\n\n<a class=\"gb-button gb-button-b8b7c3a7 gb-button-text\" href=\"#popmake-571\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u0645\u062c\u0627\u0646\u064a<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fbd03688\">\n<div class=\"gb-container gb-container-bffb56fe\">\n<div class=\"gb-container gb-container-a99e2155\">\n<div class=\"gb-container gb-container-3f80dc29\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-90995f9e\">\n<div class=\"gb-grid-column gb-grid-column-73686e68\"><div class=\"gb-container gb-container-73686e68\">\n<div class=\"gb-container gb-container-3eb15824\">\n\n<figure class=\"wp-block-video\"><video height=\"480\" style=\"aspect-ratio: 854 \/ 480;\" width=\"854\" controls loop src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/tengyi-factory.mp4\"><\/video><\/figure>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-e7736112\"><div class=\"gb-container gb-container-e7736112\">\n<div class=\"gb-container gb-container-d01331a5\">\n\n<h2 class=\"gb-headline gb-headline-874b23bf gb-headline-text\">\u0646\u0628\u0630\u0629 \u0639\u0646 \u062a\u0646\u063a\u064a\u064a<\/h2>\n\n\n\n<p class=\"gb-headline gb-headline-95857e0e gb-headline-text\">\u0646\u062d\u0646 \u0645\u0624\u0633\u0633\u0629 \u0631\u0627\u0626\u062f\u0629 \u0645\u062a\u062e\u0635\u0635\u0629 \u0641\u064a \u062a\u0635\u0645\u064a\u0645 \u0648\u062a\u0635\u0646\u064a\u0639 \u0648\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062c\u0645\u0648\u0639\u0629 \u0643\u0628\u064a\u0631\u0629 \u0645\u0646 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-f932b516 gb-headline-text\">\u064a\u063a\u0637\u064a \u0645\u0631\u0641\u0642 \u0627\u0644\u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0645\u062a\u0637\u0648\u0631 \u0644\u062f\u064a\u0646\u0627 \u0623\u0643\u062b\u0631 \u0645\u0646 11,000 \u0645\u062a\u0631 \u0645\u0631\u0628\u0639 \u0648\u064a\u062a\u0645\u064a\u0632 \u0628\u0642\u062f\u0631\u0629 \u0631\u0641\u0639 \u0642\u0635\u0648\u0649 \u062a\u0628\u0644\u063a 240 \u0637\u0646\u0627\u064b\u060c \u0645\u0645\u0627 \u064a\u062a\u064a\u062d \u0644\u0646\u0627 \u062a\u062d\u0642\u064a\u0642 \u0637\u0627\u0642\u0629 \u0625\u0646\u062a\u0627\u062c\u064a\u0629 \u0633\u0646\u0648\u064a\u0629 \u0645\u0630\u0647\u0644\u0629 \u062a\u0628\u0644\u063a 12,000 \u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-be10ada1 gb-headline-text\">\u0646\u062d\u0646 \u0646\u0648\u0641\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0646\u0637\u0627\u0642\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0645\u0646 52 \u0625\u0644\u0649 800 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c \u0645\u0639 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0637\u0627\u0642\u0629 \u062a\u062a\u0631\u0627\u0648\u062d \u0645\u0646 20 \u0625\u0644\u0649 600 \u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631\u060c \u0648\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0635\u0644 \u0633\u0639\u0627\u062a \u0645\u062d\u0648\u0644\u0627\u062a\u0646\u0627 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a\u0629 \u0625\u0644\u0649 1,000 \u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631.<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b31aff1d\">\n<div class=\"gb-container gb-container-0ff21d27\">\n<div class=\"gb-container gb-container-9ff863bf\">\n\n<h2 class=\"gb-headline gb-headline-166863e7 gb-headline-text\">\u0627\u0644\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629<\/h2>\n\n\n<div class=\"gb-container gb-container-92c8f335\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4d8d49be\">\n<div class=\"gb-grid-column gb-grid-column-68f270f9\"><div class=\"gb-container gb-container-68f270f9 box-shadow\">\n<div class=\"gb-container gb-container-f1a7aefb\">\n<div class=\"gb-container gb-container-deb3708a\">\n\n<figure class=\"gb-block-image gb-block-image-4cc7c578\"><img decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-4cc7c578\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u062d\u0627\u0644\u06291\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1.jpg 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case1-252x300.jpg 252w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-8d95318d\">\n\n<p class=\"gb-headline gb-headline-67aa1354 gb-headline-text\"><strong>\u062a\u0634\u063a\u064a\u0644 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0641\u064a \u0623\u0631\u0645\u064a\u0646\u064a\u0627<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b3be5d52\"><div class=\"gb-container gb-container-b3be5d52 box-shadow\">\n<div class=\"gb-container gb-container-6f6a573f\">\n<div class=\"gb-container gb-container-486e91c5\">\n\n<figure class=\"gb-block-image gb-block-image-1b33d975\"><img decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-1b33d975\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u062d\u0627\u0644\u06292\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2.jpg 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case2-252x300.jpg 252w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ac40903a\">\n\n<p class=\"gb-headline gb-headline-f5dae651 gb-headline-text\"><strong>P<strong>\u0623\u0648\u064a\u0631<\/strong> \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u0648\u0642\u0639 \u0641\u064a \u0627\u0644\u0633\u0644\u0641\u0627\u062f\u0648\u0631 <\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-5b43e0ba\"><div class=\"gb-container gb-container-5b43e0ba box-shadow\">\n<div class=\"gb-container gb-container-252edb0d\">\n<div class=\"gb-container gb-container-71061808\">\n\n<figure class=\"gb-block-image gb-block-image-c50e0c59\"><img decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-c50e0c59\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u062d\u0627\u0644\u06293\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3.jpg 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case3-252x300.jpg 252w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-639c032c\">\n\n<p class=\"gb-headline gb-headline-3ab9e394 gb-headline-text\"><strong>P<strong>\u0623\u0648\u064a\u0631<\/strong> \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u064a \u0627\u0644\u0633\u0646\u063a\u0627\u0644<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-568b7687\"><div class=\"gb-container gb-container-568b7687 box-shadow\">\n<div class=\"gb-container gb-container-720db38c\">\n<div class=\"gb-container gb-container-807afc16\">\n\n<figure class=\"gb-block-image gb-block-image-e6413539\"><img decoding=\"async\" width=\"420\" height=\"500\" class=\"gb-image gb-image-e6413539\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u062d\u0627\u0644\u06294\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4.jpg 420w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-case4-252x300.jpg 252w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/><\/figure>\n\n<\/div>\n\n<div class=\"gb-container gb-container-ae140dd6\">\n\n<p class=\"gb-headline gb-headline-58ea974c gb-headline-text\"><strong>P<strong>\u0623\u0648\u064a\u0631<\/strong> \u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u064a \u0633\u0646\u063a\u0627\u0641\u0648\u0631\u0629<\/strong><\/p>\n\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-93bd4d7a\">\n\n<a class=\"gb-button gb-button-268bab37 gb-button-text\" href=\"#popmake-573\">\u062a\u062e\u0635\u064a\u0635 \u0645\u0634\u0627\u0631\u064a\u0639\u0643<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9b106039\">\n<div class=\"gb-container gb-container-222eb79e\">\n<div class=\"gb-container gb-container-c267a5c3\">\n\n<h2 class=\"gb-headline gb-headline-269e49db gb-headline-text\">\u0622\u0631\u0627\u0621 \u0627\u0644\u0639\u0645\u0644\u0627\u0621<\/h2>\n\n\n<div class=\"gb-container gb-container-598617b6\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-a1cf8e8f\">\n<div class=\"gb-grid-column gb-grid-column-0876043a\"><div class=\"gb-container gb-container-0876043a box-shadow\">\n<div class=\"gb-container gb-container-cb854a33\">\n\n<p class=\"gb-headline gb-headline-a7e17eaa gb-headline-text\"><strong>\u0623\u062a\u0627\u0631\u0648\u0627\u064a\u0632\u0648\u0646\u062f\u064a\u0646<\/strong><\/p>\n\n\n\n<p><strong>- \u0645\u0646 \u062a\u0648\u063a\u0648<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d5d293e6 gb-headline-text\">\u0644\u0642\u062f \u0642\u0644\u0644\u062a \u0645\u062d\u0648\u0644\u0627\u062a Tengyi \u0645\u0646 \u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u062f\u064a\u0646\u0627 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631. \u0648\u064a\u0636\u0645\u0646 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0648\u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0642\u0648\u064a \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629\u060c \u062d\u062a\u0649 \u0623\u062b\u0646\u0627\u0621 \u0630\u0631\u0648\u0629 \u0627\u0644\u0623\u062d\u0645\u0627\u0644. \u0646\u062d\u0646 \u0631\u0627\u0636\u0648\u0646 \u062c\u062f\u064b\u0627 \u0639\u0646 \u062c\u0648\u062f\u062a\u0647\u0627 \u0648\u0643\u0641\u0627\u0621\u062a\u0647\u0627.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-9408837f gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-defb5ca7\"><div class=\"gb-container gb-container-defb5ca7 box-shadow\">\n<div class=\"gb-container gb-container-f5ea4cf7\">\n\n<p class=\"gb-headline gb-headline-635a1ae5 gb-headline-text\"><strong>\u0623\u0648\u0644\u0627\u0628\u0648\u062f \u062a\u0648\u0632\u064a\u0646<\/strong><\/p>\n\n\n\n<p><strong>- \u0645\u0646 \u0646\u064a\u062c\u064a\u0631\u064a\u0627<\/strong><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-39aca2b2 gb-headline-text\">\u0623\u062b\u0628\u062a\u062a \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0627\u0644\u062a\u064a \u0646\u0634\u062a\u0631\u064a\u0647\u0627 \u0645\u0646 Tengyi \u0623\u0646\u0647\u0627 \u0645\u062a\u064a\u0646\u0629 \u0644\u0644\u063a\u0627\u064a\u0629. \u0648\u062d\u062a\u0649 \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0642\u0627\u0633\u064a\u0629\u060c \u0641\u0625\u0646\u0647\u0627 \u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0623\u062f\u0627\u0626\u0647\u0627 \u0648\u0644\u0627 \u062a\u0638\u0647\u0631 \u0639\u0644\u064a\u0647\u0627 \u0623\u064a \u0639\u0644\u0627\u0645\u0627\u062a \u062a\u0622\u0643\u0644\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0639\u0645\u0644\u064a\u0627\u062a\u0646\u0627.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-d438266a gb-headline-text\">\u2605\u2605\u2605\u2605\u2605<\/p>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-a7c9826f\">\n<div class=\"gb-container gb-container-2d15f96e\">\n<div class=\"gb-container gb-container-b509a5ca\">\n\n<h2 class=\"gb-headline gb-headline-af18f263 gb-headline-text\">\u0648\u0631\u0634\u0629 \u0639\u0645\u0644 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629<\/h2>\n\n\n<div class=\"gb-container gb-container-afb8e67c\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-ec04d4c9\">\n<div class=\"gb-grid-column gb-grid-column-16bc3c39\"><div class=\"gb-container gb-container-16bc3c39\">\n\n<figure class=\"gb-block-image gb-block-image-4c25ac61\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4c25ac61\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1.jpg\" alt=\"\" title=\"\u0648\u0631\u0634\u0629 \u0639\u0645\u0644 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u06291\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop1-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-cdac3a5c\"><div class=\"gb-container gb-container-cdac3a5c\">\n\n<figure class=\"gb-block-image gb-block-image-d1d511b7\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-d1d511b7\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2.jpg\" alt=\"\" title=\"\u0648\u0631\u0634\u0629 \u0639\u0645\u0644 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u06292\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop2-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-83b1f304\"><div class=\"gb-container gb-container-83b1f304\">\n\n<figure class=\"gb-block-image gb-block-image-9595ad8a\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-9595ad8a\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3.jpg\" alt=\"\" title=\"\u0648\u0631\u0634\u0629 \u0639\u0645\u0644 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u06293\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop3-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-0f93ff24\"><div class=\"gb-container gb-container-0f93ff24\">\n\n<figure class=\"gb-block-image gb-block-image-4f95db6c\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-4f95db6c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4.jpg\" alt=\"\" title=\"\u0648\u0631\u0634\u0629 \u0639\u0645\u0644 \u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u06294\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-workshop4-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b5b41c7b\">\n<div class=\"gb-container gb-container-07e5685b\">\n<div class=\"gb-container gb-container-b4e2f617\">\n\n<h2 class=\"gb-headline gb-headline-db58d5b7 gb-headline-text\">\u062a\u0641\u0627\u0635\u064a\u0644 \u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n\n\n<div class=\"gb-container gb-container-0320fa24\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-3e7d62cb\">\n<div class=\"gb-grid-column gb-grid-column-68e263cc\"><div class=\"gb-container gb-container-68e263cc\">\n\n<figure class=\"gb-block-image gb-block-image-4fc14921\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-4fc14921\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0625\u0646\u062a\u0627\u062c-\u062a\u0641\u0627\u0635\u064a\u0644-\u0625\u0646\u062a\u0627\u062c-\u062a\u0641\u0627\u0635\u064a\u06441\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details1-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-64cafa73\"><div class=\"gb-container gb-container-64cafa73\">\n\n<figure class=\"gb-block-image gb-block-image-c5762194\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-c5762194\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2.jpg\" alt=\"\" title=\"\u062a\u0641\u0627\u0635\u064a\u0644 \u0625\u0646\u062a\u0627\u062c \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u06292\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details2-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b5f12304\"><div class=\"gb-container gb-container-b5f12304\">\n\n<figure class=\"gb-block-image gb-block-image-cf22cbbc\"><img decoding=\"async\" width=\"565\" height=\"420\" class=\"gb-image gb-image-cf22cbbc\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0625\u0646\u062a\u0627\u062c-\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u062a\u0641\u0627\u0635\u064a\u06441\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1.jpg 565w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/power-transformer-production-details1-300x223.jpg 300w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-84602a06\"><div class=\"gb-container gb-container-84602a06\">\n\n<figure class=\"gb-block-image gb-block-image-37efc46b\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-37efc46b\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0625\u0646\u062a\u0627\u062c-\u062a\u0641\u0627\u0635\u064a\u0644-\u0625\u0646\u062a\u0627\u062c-\u062a\u0641\u0627\u0635\u064a\u06444\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-production-details4-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ff98aefa\">\n<div class=\"gb-container gb-container-09841b9b\">\n<div class=\"gb-container gb-container-4df5c905\">\n\n<h2 class=\"gb-headline gb-headline-ef1fb936 gb-headline-text\">\u0634\u062d\u0646 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/h2>\n\n\n<div class=\"gb-container gb-container-bacb2a7a\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-7bf0f241\">\n<div class=\"gb-grid-column gb-grid-column-7839f0e5\"><div class=\"gb-container gb-container-7839f0e5\">\n\n<figure class=\"gb-block-image gb-block-image-385cff22\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-385cff22\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0634\u062d\u0646-\u0634\u062d\u06462\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment2-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-192e64a3\"><div class=\"gb-container gb-container-192e64a3\">\n\n<figure class=\"gb-block-image gb-block-image-f5d9b28c\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-f5d9b28c\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0634\u062d\u0646-\u0634\u062d\u06461\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment1-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6d1225ce\"><div class=\"gb-container gb-container-6d1225ce\">\n\n<figure class=\"gb-block-image gb-block-image-c7e967d0\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-c7e967d0\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0634\u062d\u0646-\u0634\u062d\u06463\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment3-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-c58b010c\"><div class=\"gb-container gb-container-c58b010c\">\n\n<figure class=\"gb-block-image gb-block-image-0a5acc3d\"><img decoding=\"async\" width=\"1702\" height=\"1276\" class=\"gb-image gb-image-0a5acc3d\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4.jpg\" alt=\"\" title=\"\u0645\u062d\u0648\u0644-\u0634\u062d\u0646-\u0634\u062d\u06464\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4.jpg 1702w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-300x225.jpg 300w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-1024x768.jpg 1024w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-768x576.jpg 768w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/transformer-shipment4-1536x1152.jpg 1536w\" sizes=\"(max-width: 1702px) 100vw, 1702px\" \/><\/figure>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-90cdd9d3\">\n<div class=\"gb-container gb-container-5d804c55\">\n<div class=\"gb-container gb-container-b4ecb024\">\n\n<h2 class=\"gb-headline gb-headline-2cbe547e gb-headline-text\">\u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a<\/h2>\n\n\n<div class=\"gb-container gb-container-8eaadcb8\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-46ed5465\">\n<div class=\"gb-grid-column gb-grid-column-18dc6766\"><div class=\"gb-container gb-container-18dc6766\">\n\n<figure class=\"gb-block-image gb-block-image-d25ab0e0\"><img decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-d25ab0e0\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core.jpg\" alt=\"\" title=\"\u0627\u0644\u0646\u0648\u0627\u0629\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core.jpg 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/core-255x300.jpg 255w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-bcfbbbb6\"><div class=\"gb-container gb-container-bcfbbbb6\">\n\n<h3 class=\"gb-headline gb-headline-03831c9f gb-headline-text\">\u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0627\u062a<\/h3>\n\n\n\n<p>\u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0644\u0640 Tengyi <strong>\u0635\u0641\u0627\u0626\u062d \u0641\u0648\u0644\u0627\u0630\u064a\u0629 \u0645\u0646 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0648\u0646 \u0627\u0644\u0645\u062f\u0631\u0641\u0644\u0629 \u0639\u0644\u0649 \u0627\u0644\u0628\u0627\u0631\u062f \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0648\u0627\u0644\u0645\u0648\u062c\u0647\u0629 \u0628\u0627\u0644\u062d\u0628\u0648\u0628 \u0648\u0630\u0627\u062a \u062a\u0648\u0635\u064a\u0644 \u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0639\u0627\u0644\u064a \u0627\u0644\u062c\u0648\u062f\u0629<\/strong>. \u062a\u0636\u0645\u0646 \u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u0642\u0635 \u0627\u0644\u0622\u0644\u064a \u0627\u0644\u0645\u062a\u0642\u062f\u0645\u0629 \u0623\u0646 \u062a\u0643\u0648\u0646 \u0627\u0644\u0646\u062a\u0648\u0621\u0627\u062a \u0639\u0644\u0649 \u062d\u0648\u0627\u0641 \u0627\u0644\u0642\u0637\u0639 \u0623\u0642\u0644 \u0645\u0646 0.02 \u0645\u0645.<\/p>\n\n\n\n<p>\u064a\u062a\u0645 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u062a\u0635\u0645\u064a\u0645 \u0646\u064a\u0631 \u0641\u0631\u064a\u062f \u0645\u0646 \u0646\u0648\u0639\u0647 \u063a\u064a\u0631 \u0645\u062a\u062f\u0627\u062e\u0644\u060c \u0645\u0639 \u0635\u0641\u0627\u0626\u062d \u0641\u0648\u0644\u0627\u0630\u064a\u0629 \u0645\u0646 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0648\u0646 \u0645\u062a\u0635\u0644\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0648\u0635\u0644\u0629 \u0645\u062a\u062f\u0631\u062c\u0629 \u0628\u0632\u0627\u0648\u064a\u0629 45 \u062f\u0631\u062c\u0629 \u0643\u0627\u0645\u0644\u0629 \u0627\u0644\u0627\u0646\u062d\u062f\u0627\u0631. \u0628\u0639\u062f \u0627\u0644\u062a\u0643\u062f\u064a\u0633\u060c \u064a\u062a\u0645 \u0636\u063a\u0637 \u0627\u0644\u0642\u0644\u0628 (\u062b\u0644\u0627\u062b\u0629 \u0623\u0639\u0645\u062f\u0629 \u0648\u0646\u064a\u0631\u064a\u0646) \u0648\u0631\u0628\u0637\u0647 \u0628\u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u060c \u0645\u0645\u0627 \u064a\u062e\u0644\u0642 \u062a\u062c\u0645\u064a\u0639\u064b\u0627 \u0635\u0644\u0628\u064b\u0627 \u0648\u0645\u0633\u0637\u062d\u064b\u0627 \u0628\u062f\u0642\u0629 \u0631\u0623\u0633\u064a\u0629 \u0639\u0627\u0644\u064a\u0629. \u0648\u0647\u0630\u0627 \u064a\u062d\u0633\u0646 \u0623\u062f\u0627\u0621 \u0639\u062f\u0645 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0648\u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u0636\u0648\u0636\u0627\u0621.<\/p>\n\n\n\n<p>\u062a\u062b\u0628\u062a \u0623\u0644\u0648\u0627\u062d \u0627\u0644\u062f\u0639\u0645 \u0623\u0639\u0645\u062f\u0629 \u0627\u0644\u0642\u0644\u0628 \u0639\u0644\u0649 \u0627\u0644\u0644\u0641\u0627\u062a \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629. \u064a\u062a\u0645 \u0625\u062d\u0643\u0627\u0645 \u0631\u0628\u0637 \u0627\u0644\u0646\u064a\u0631 \u0628\u0634\u0631\u064a\u0637 \u0645\u0646 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0632\u062c\u0627\u062c\u064a\u0629 \u0627\u0644\u0645\u0634\u0628\u0639\u0629 \u0628\u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u060c \u0648\u064a\u062a\u0645 \u062a\u062b\u0628\u064a\u062a \u0627\u0644\u0646\u064a\u0631 \u0627\u0644\u0633\u0641\u0644\u064a \u0628\u0625\u062d\u0643\u0627\u0645 \u0639\u0644\u0649 \u0642\u0633\u0645 \u062e\u0632\u0627\u0646 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0641\u0644\u064a \u0628\u0648\u0627\u0633\u0637\u0629 \u0628\u0631\u0627\u063a\u064a \u0645\u0636\u0627\u062f\u0629 \u0644\u0644\u0636\u063a\u0637. \u0648\u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0630\u0644\u0643\u060c \u064a\u062a\u0645 \u062a\u062b\u0628\u064a\u062a \u0627\u0644\u0646\u064a\u0631 \u0627\u0644\u0639\u0644\u0648\u064a \u0639\u0644\u0649 \u0642\u0633\u0645 \u062e\u0632\u0627\u0646 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0639\u0644\u0648\u064a \u0641\u064a \u062b\u0644\u0627\u062b \u0646\u0642\u0627\u0637\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0628\u0642\u0627\u0621 \u0642\u0644\u0628 \u0627\u0644\u0645\u062d\u0648\u0644 \u062b\u0627\u0628\u062a\u064b\u0627 \u0648\u063a\u064a\u0631 \u0645\u062a\u062d\u0631\u0643 \u062f\u0627\u062e\u0644 \u0627\u0644\u062e\u0632\u0627\u0646 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0646\u0642\u0644.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-fd34f3cb\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-636a974e\">\n<div class=\"gb-grid-column gb-grid-column-164aa8db\"><div class=\"gb-container gb-container-164aa8db\">\n\n<figure class=\"gb-block-image gb-block-image-a62dd677\"><img decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-a62dd677\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding.jpg\" alt=\"\" title=\"\u0627\u0644\u0644\u0641\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding.jpg 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/winding-255x300.jpg 255w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-1c24590a\"><div class=\"gb-container gb-container-1c24590a\">\n\n<h3 class=\"gb-headline gb-headline-f9a16617 gb-headline-text\">\u0627\u0644\u0644\u0641\u0627\u062a<\/h3>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0644\u0641\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0645\u0646 Tengyi \u0647\u064a\u0643\u0644\u064b\u0627 \u0645\u062a\u0635\u0644\u064b\u0627 \u0648\u0645\u062c\u062f\u0648\u0644\u0627\u064b \u0644\u062a\u062d\u0633\u064a\u0646 \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u062c\u0647\u062f \u0641\u064a \u0638\u0644 \u0638\u0631\u0648\u0641 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u0645\u062c\u0627\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u0643\u062b\u0631 \u0627\u062a\u0633\u0627\u0642\u064b\u0627. \u062a\u0639\u0645\u0644 \u0627\u0644\u062d\u0648\u0627\u0641 \u0627\u0644\u0645\u0633\u062a\u062f\u064a\u0631\u0629 \u0639\u0644\u0649 \u0647\u064a\u0627\u0643\u0644 \u0627\u0644\u062f\u0639\u0645 \u0648\u0627\u0644\u0641\u0648\u0627\u0635\u0644 \u0639\u0644\u0649 \u062a\u0639\u0632\u064a\u0632 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0639\u0632\u0644.<\/p>\n\n\n\n<p>\u064a\u0634\u062a\u0645\u0644 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u062f\u0627\u062e\u0644\u064a \u0644\u0644\u0645\u0644\u0641 \u0639\u0644\u0649 \u0647\u064a\u0643\u0644 \u0645\u062c\u0631\u0649 \u0632\u064a\u062a \u0645\u062a\u0639\u0631\u062c \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0634\u0627\u0645\u0644 \u0641\u064a \u062c\u0645\u064a\u0639 \u0623\u0646\u062d\u0627\u0621 \u0627\u0644\u0644\u0641\u0627\u062a\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u0628\u0642\u0639 \u0627\u0644\u0633\u0627\u062e\u0646\u0629\u060c \u0648\u064a\u0637\u064a\u0644 \u0639\u0645\u0631 \u0627\u0644\u0639\u0632\u0644.<\/p>\n\n\n\n<p>\u064a\u062a\u0645 \u062a\u0648\u0641\u064a\u0631 \u0644\u0641\u0627\u062a \u062d\u0646\u0641\u064a\u0629 \u0645\u0646\u0641\u0635\u0644\u0629 \u0644\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u060c \u0645\u0645\u0627 \u064a\u0648\u0627\u0632\u0646 \u0628\u064a\u0646 \u0644\u0641\u0627\u062a \u0627\u0644\u0623\u0645\u0628\u064a\u0631 \u0641\u064a \u0643\u0644 \u0644\u0641\u0629. \u0648\u0647\u0630\u0627 \u064a\u0642\u0644\u0644 \u0628\u0641\u0639\u0627\u0644\u064a\u0629 \u0645\u0646 \u0627\u0644\u0642\u0648\u0649 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0631\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629\u060c \u0645\u0645\u0627 \u064a\u062d\u0633\u0646 \u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0644\u0649 \u062a\u062d\u0645\u0644 \u0623\u062d\u062f\u0627\u062b \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629. \u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0644\u0641\u0627\u062a \u062a\u0635\u0645\u064a\u0645\u064b\u0627 \u0634\u0639\u0627\u0639\u064a\u064b\u0627 \"\u0635\u0641\u0631\u064a \u0627\u0644\u0647\u0627\u0645\u0634\". \u064a\u062a\u0645 \u062a\u0646\u0641\u064a\u0630 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u062f\u0642\u064a\u0642 \u0648\u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u062f\u0642\u064a\u0642 \u0628\u064a\u0646 \u0627\u0644\u0642\u0644\u0628 \u0648\u0645\u0644\u0641 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u060c \u0648\u0628\u064a\u0646 \u0644\u0641\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0627\u0644\u0644\u0641\u0627\u0626\u0641 \u0627\u0644\u062d\u0646\u0641\u064a\u0629\u060c \u0648\u0628\u064a\u0646 \u0647\u064a\u0627\u0643\u0644 \u0627\u0644\u062f\u0639\u0645 \u0648\u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u062d\u064a\u0637\u0629. \u0648\u0647\u0630\u0627 \u064a\u0636\u0645\u0646 \u0627\u0646\u0636\u063a\u0627\u0637 \u0627\u0644\u0644\u0641 \u0648\u062a\u0631\u0643\u064a\u0632\u0647 \u0628\u0634\u0643\u0644 \u0627\u0633\u062a\u062b\u0646\u0627\u0626\u064a.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-63f0b4ed\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-0840434b\">\n<div class=\"gb-grid-column gb-grid-column-bafa936a\"><div class=\"gb-container gb-container-bafa936a\">\n\n<figure class=\"gb-block-image gb-block-image-11c49a78\"><img decoding=\"async\" width=\"400\" height=\"470\" class=\"gb-image gb-image-11c49a78\" src=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank.jpg\" alt=\"\" title=\"\u062e\u0632\u0627\u0646 \u0627\u0644\u0632\u064a\u062a\" srcset=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank.jpg 400w, https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/oil-tank-255x300.jpg 255w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-6522b706\"><div class=\"gb-container gb-container-6522b706\">\n\n<h3 class=\"gb-headline gb-headline-4fe49ec8 gb-headline-text\">\u062e\u0632\u0627\u0646 \u0627\u0644\u0632\u064a\u062a<\/h3>\n\n\n\n<p>\u0635\u064f\u0646\u0639 \u0635\u0647\u0631\u064a\u062c \u062a\u062e\u0632\u064a\u0646 \u0627\u0644\u0632\u064a\u062a \u0645\u0646 Tengyi \u0645\u0646 \u0635\u0641\u064a\u062d\u0629 \u0641\u0648\u0644\u0627\u0630\u064a\u0629 \u0639\u0631\u064a\u0636\u0629 \u0623\u062d\u0627\u062f\u064a\u0629 \u0627\u0644\u0642\u0637\u0639\u0629 \u0645\u064f\u0634\u0643\u064e\u0651\u0644\u0629 \u0641\u064a \u0647\u064a\u0643\u0644 \u0645\u0645\u0648\u062c. \u064a\u0624\u062f\u064a \u0630\u0644\u0643 \u0625\u0644\u0649 \u0627\u0644\u062a\u062e\u0644\u0635 \u0645\u0646 \u0627\u0644\u0644\u062d\u0627\u0645\u0627\u062a\u060c \u0645\u0645\u0627 \u064a\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0648\u064a\u0648\u0641\u0631 \u062a\u0623\u062b\u064a\u0631 \u062a\u0628\u062f\u064a\u062f \u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u0636\u0648\u0636\u0627\u0621. \u0642\u0646\u0648\u0627\u062a \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0648\u062e\u0632\u0627\u0646\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0635\u0646\u0648\u0639\u0629 \u0645\u0646 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u062a\u0635\u0645\u064a\u0645 \u0646\u0638\u064a\u0641 \u0648\u0645\u0645\u062a\u0639 \u0645\u0646 \u0627\u0644\u0646\u0627\u062d\u064a\u0629 \u0627\u0644\u062c\u0645\u0627\u0644\u064a\u0629.<\/p>\n\n\n\n<p>\u062a\u0645 \u062a\u0634\u0643\u064a\u0644 \u062c\u0645\u064a\u0639 \u0623\u0633\u0637\u062d \u0645\u0627\u0646\u0639 \u0627\u0644\u062a\u0633\u0631\u0628 \u0628\u062f\u0642\u0629 \u0648\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0648\u0627\u062f \u0645\u0627\u0646\u0639\u0629 \u0644\u0644\u062a\u0633\u0631\u0628 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0648\u062f\u0629. \u064a\u062a\u0645\u064a\u0632 \u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0639\u0644\u0648\u064a \u0645\u0646 \u0627\u0644\u062e\u0632\u0627\u0646 \u0628\u0623\u062e\u062f\u0648\u062f \u0645\u0632\u062f\u0648\u062c \u0645\u0627\u0646\u0639 \u0644\u0644\u062a\u0633\u0631\u0628\u060c \u062d\u064a\u062b \u064a\u062d\u0645\u064a \u0645\u0627\u0646\u0639 \u0627\u0644\u062a\u0633\u0631\u0628 \u0627\u0644\u062e\u0627\u0631\u062c\u064a \u0645\u0627\u0646\u0639 \u0627\u0644\u062a\u0633\u0631\u0628 \u0627\u0644\u062f\u0627\u062e\u0644\u064a \u0645\u0646 \u0627\u0644\u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062c\u0648\u064a\u0629 \u0648\u0627\u0644\u0623\u0634\u0639\u0629 \u0641\u0648\u0642 \u0627\u0644\u0628\u0646\u0641\u0633\u062c\u064a\u0629\u060c \u0645\u0645\u0627 \u064a\u0632\u064a\u062f \u0645\u0646 \u0639\u0645\u0631 \u0645\u0627\u0646\u0639 \u0627\u0644\u062a\u0633\u0631\u0628 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u062a\u0647.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-20bfcb6f\">\n\n<h3 class=\"gb-headline gb-headline-871dc461 gb-headline-text\">\u0645\u0643\u0648\u0646\u0627\u062a \u0623\u062e\u0631\u0649<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a:<\/strong>&nbsp;\u0648\u0647\u064a \u0639\u0648\u0627\u0632\u0644 \u062a\u0633\u0645\u062d \u0644\u0644\u0623\u0633\u0644\u0627\u0643 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0628\u0627\u0644\u0645\u0631\u0648\u0631 \u0628\u0623\u0645\u0627\u0646 \u0639\u0628\u0631 \u062c\u062f\u0627\u0631 \u0627\u0644\u062e\u0632\u0627\u0646 \u062f\u0648\u0646 \u0627\u0644\u0645\u062e\u0627\u0637\u0631\u0629 \u0628\u062d\u062f\u0648\u062b \u062a\u0642\u0648\u0633 \u0623\u0648 \u0645\u0627\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u0647\u064a \u0645\u0635\u0645\u0645\u0629 \u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0648\u062a\u0648\u0641\u0631 \u0639\u0632\u0644\u064b\u0627 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u064b\u0627 \u0645\u0648\u062b\u0648\u0642\u064b\u0627.<\/p>\n\n\n\n<p><strong>\u0646\u0638\u0627\u0645 \u0627\u0644\u0639\u0632\u0644:<\/strong>&nbsp;\u0648\u0647\u0648 \u064a\u0645\u0646\u0639 \u0627\u0644\u0648\u0645\u0636\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 (\u0623\u0642\u0648\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621) \u0648\u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0628\u064a\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u0648\u0627\u0644\u0642\u0644\u0628\u060c \u0623\u0648 \u0628\u064a\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u0646\u0641\u0633\u0647\u0627. \u0648\u064a\u062a\u0643\u0648\u0646 \u0647\u0630\u0627 \u0627\u0644\u0646\u0638\u0627\u0645 \u0645\u0646 \u0637\u0628\u0642\u0627\u062a \u0645\u062a\u0639\u062f\u062f\u0629 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0635\u0644\u0628 (\u0645\u062b\u0644 \u0627\u0644\u0648\u0631\u0642 \u0648\u0627\u0644\u0648\u0631\u0642 \u0627\u0644\u0645\u0642\u0648\u0649 \u0648\u0627\u0644\u0648\u0631\u0642 \u0627\u0644\u0645\u0642\u0648\u0649) \u0648\u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0633\u0627\u0626\u0644 (\u0645\u062b\u0644 \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a). \u0648\u064a\u0639\u0645\u0644 \u0627\u0644\u0632\u064a\u062a \u0623\u064a\u0636\u0627\u064b \u0639\u0644\u0649 \u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<p><strong>\u0645\u063a\u064a\u0651\u0631 \u0627\u0644\u0646\u0642\u0631:<\/strong>&nbsp;\u0647\u0630\u0627 \u0645\u0643\u0648\u0646 \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u060c \u0648\u0644\u0643\u0646\u0647 \u0634\u0627\u0626\u0639 \u062c\u062f\u0627\u064b \u0641\u064a \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a. \u0648\u0647\u0648 \u064a\u0633\u0645\u062d \u0628\u062a\u0639\u062f\u064a\u0644 \u062c\u0647\u062f \u0627\u0644\u062e\u0631\u062c \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u062c\u0647\u062f \u062b\u0627\u0628\u062a\u060c \u062d\u062a\u0649 \u0644\u0648 \u062a\u063a\u064a\u0631 \u062c\u0647\u062f \u0627\u0644\u062f\u062e\u0644 \u0623\u0648 \u0627\u0644\u062d\u0645\u0644. \u0648\u064a\u0648\u062c\u062f \u0639\u0627\u062f\u0629\u064b \u0639\u0644\u0649 \u0627\u0644\u0644\u0641 \u0627\u0644\u062b\u0627\u0646\u0648\u064a \u0648\u064a\u0645\u0643\u0646 \u0636\u0628\u0637\u0647 \u0623\u062b\u0646\u0627\u0621 \u062a\u0646\u0634\u064a\u0637 \u0627\u0644\u0645\u062d\u0648\u0644 (\u062a\u062d\u062a \u062a\u063a\u064a\u064a\u0631 \u0627\u0644\u062d\u0645\u0644) \u0623\u0648 \u0625\u0644\u063a\u0627\u0621 \u062a\u0646\u0634\u064a\u0637\u0647.<\/p>\n\n\n\n<p><strong>\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f:<\/strong>&nbsp;\u062a\u0648\u0644\u062f \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u062d\u0631\u0627\u0631\u0629 \u0643\u0628\u064a\u0631\u0629\u060c \u0644\u0630\u0627 \u0641\u0625\u0646 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0641\u0639\u0627\u0644 \u0636\u0631\u0648\u0631\u064a. \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u0634\u0645\u0644 \u0630\u0644\u0643 \u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0623\u0648 \u062d\u062a\u0649 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0628\u0627\u0644\u0645\u0627\u0621\u060c \u0627\u0639\u062a\u0645\u0627\u062f\u064b\u0627 \u0639\u0644\u0649 \u062d\u062c\u0645 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u062a\u0635\u0646\u064a\u0641 \u0637\u0627\u0642\u062a\u0647. \u064a\u0639\u062f \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0623\u0645\u0631\u064b\u0627 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062f\u0631\u062c\u0627\u062a \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646\u0629 \u0648\u0645\u0646\u0639 \u0627\u0644\u062a\u0644\u0641.<\/p>\n\n\n\n<p>\u062a\u0639\u0645\u0644 \u0647\u0630\u0647 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0645\u0639\u064b\u0627 \u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0628\u0643\u0641\u0627\u0621\u0629 \u0648\u0623\u0645\u0627\u0646 \u0625\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0644\u0644\u062a\u0648\u0632\u064a\u0639 \u0623\u0648 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645. \u064a\u062e\u062a\u0644\u0641 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u062f\u0642\u064a\u0642 \u0648\u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0628\u0627\u062e\u062a\u0644\u0627\u0641 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u062d\u062f\u062f \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-cd9f29d2\">\n\n<a class=\"gb-button gb-button-fddd53b9 gb-button-text\" href=\"#popmake-573\">\u062a\u062d\u062f\u062b \u0625\u0644\u0649 \u062e\u0628\u0631\u0627\u0626\u0646\u0627 \u0627\u0644\u0622\u0646<\/a>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b389f44f\">\n<div class=\"gb-container gb-container-2c68dd12\">\n<div class=\"gb-container gb-container-702d50c7\">\n<div class=\"gb-container gb-container-1bdbd7d4\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-4967a93a\">\n<div class=\"gb-grid-column gb-grid-column-3e0e599b\"><div class=\"gb-container gb-container-3e0e599b\">\n<div class=\"gb-container gb-container-1cf38dc2\">\n\n<h2 class=\"gb-headline gb-headline-81cda2cf gb-headline-text\">\u0627\u0642\u062a\u0628\u0627\u0633 \u0645\u062d\u0648\u0644 \u062a\u0646\u062c\u064a\u064a<\/h2>\n\n\n\n<p>\u0646\u062d\u0646 \u0646\u0642\u062f\u0645 \u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0628\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062c\u0647\u062f \u0645\u062a\u0641\u0627\u0648\u062a\u0629 \u0644\u062a\u0644\u0628\u064a\u0629 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0634\u0628\u0643\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0648\u0637\u0646\u064a\u0629 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0648\u062a\u0642\u062f\u064a\u0645 \u062e\u062f\u0645\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5a5e7314\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0627\u0644\u0645\u0639\u0644\u0645\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0644\u0645\u062d\u0648\u0644 (\u0627\u0644\u062c\u0647\u062f \u0648\u0627\u0644\u0633\u0639\u0629 \u0648\u0627\u0644\u0641\u0627\u0642\u062f \u0648\u063a\u064a\u0631\u0647\u0627)\u061f<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-400a0365\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0628\u064a\u0626\u0629 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 (\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u060c \u0648\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c \u0648\u0627\u0644\u0645\u0648\u0642\u0639\u060c \u0648\u0645\u0627 \u0625\u0644\u0649 \u0630\u0644\u0643)\u061f<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-4a9dfbde\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0645\u062e\u0635\u0635\u0629 \u0623\u062e\u0631\u0649 (\u0645\u063a\u064a\u0631 \u0627\u0644\u0635\u0646\u0628\u0648\u0631\u060c \u0627\u0644\u0644\u0648\u0646\u060c \u0648\u0633\u0627\u062f\u0629 \u0627\u0644\u0632\u064a\u062a\u060c \u0625\u0644\u062e)\u061f<\/span><\/p>\n\n\n\n<p class=\"gb-headline gb-headline-5acd21ee\"><span class=\"gb-icon\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M173.898 439.404l-166.4-166.4c-9.997-9.997-9.997-26.206 0-36.204l36.203-36.204c9.997-9.998 26.207-9.998 36.204 0L192 312.69 432.095 72.596c9.997-9.997 26.207-9.997 36.204 0l36.203 36.204c9.997 9.997 9.997 26.206 0 36.204l-294.4 294.401c-9.998 9.997-26.207 9.997-36.204-.001z\"><\/path><\/svg><\/span><span class=\"gb-headline-text\">\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u0637\u0644\u0628: 1 \u0648\u062d\u062f\u0629<\/span><\/p>\n\n<\/div>\n<\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-1f62aadb\"><div class=\"gb-container gb-container-1f62aadb\">\n<div class=\"gb-container gb-container-fde8cba9\">\n\n<div class=\"wp-block-contact-form-7-contact-form-selector\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f14-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"14\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/ar\/wp-json\/wp\/v2\/pages\/912#wpcf7-f14-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"\u0646\u0645\u0648\u0630\u062c \u0627\u0644\u0627\u062a\u0635\u0627\u0644\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/ar\/wp-json\/wp\/v2\/pages\/912#wpcf7-f14-o1\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"14\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f14-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<p><label><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"\u0627\u0644\u0627\u0633\u0645*\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><\/label>\n<\/p>\n<p><label><span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"\u0627\u0644\u0628\u0631\u064a\u062f \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a*\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><\/label>\n<\/p>\n<p><label><span class=\"wpcf7-form-control-wrap\" data-name=\"your-tel\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"\u0627\u0644\u0647\u0627\u062a\u0641*\" value=\"\" type=\"tel\" name=\"your-tel\" \/><\/span><\/label>\n<\/p>\n<p><label><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"\u0627\u0644\u0631\u0633\u0627\u0644\u0629*: 1. \u0645\u0627 \u0647\u064a \u0633\u0639\u062a\u0643 \u0627\u0644\u0645\u0642\u062f\u0631\u0629\u061f (kVA)2. \u0645\u0627 \u0647\u0648 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643\u061f(kV)3. \u0645\u0627 \u0647\u0648 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u062e\u0627\u0635 \u0628\u0643\u061f (\u0647\u0631\u062a\u0632)4. \u0645\u0627 \u0647\u064a \u0627\u0644\u0645\u0627\u062f\u0629 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u0629\u060c \u0627\u0644\u0646\u062d\u0627\u0633\/\u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645\u061f 5. \u0645\u0627 \u0647\u064a \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u0645\u0634\u0627\u0631\u064a\u0639 \u0648\u0645\u0648\u0627\u0642\u0639 \u0645\u062d\u062f\u062f\u0629\u061f\" name=\"your-message\"><\/textarea><\/span> <\/label>\n<\/p>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"\u0625\u0631\u0633\u0627\u0644\" \/>\n<\/p><input type=\"hidden\" id=\"ct_checkjs_cf7_f5f8590cd58a54e94377e6ae2eded4d9\" name=\"ct_checkjs_cf7\" value=\"0\" \/><script >setTimeout(function(){var ct_input_name = \"ct_checkjs_cf7_f5f8590cd58a54e94377e6ae2eded4d9\";if (document.getElementById(ct_input_name) !== null) {var ct_input_value = document.getElementById(ct_input_name).value;document.getElementById(ct_input_name).value = document.getElementById(ct_input_name).value.replace(ct_input_value, '80a51f0b9029a6e0753aea88d00a1a1f4ca1ee354cc6f6bb1f6baa8ba292f384');}}, 1000);<\/script><input type='hidden' class='wpcf7-pum' value='{\"closepopup\":false,\"closedelay\":0,\"openpopup\":false,\"openpopup_id\":0}' \/><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"ar\"\/><\/form>\n<\/div>\n<\/div>\n\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Power Transformer Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services. Tengyi Power Transformer Advantages Tengyi main power transformer provides efficient voltage transformation, ensuring &#8230; <\/p>\n<p class=\"read-more-container\"><a title=\"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 SRKWDC\" class=\"read-more button\" href=\"https:\/\/tengyielectric.com\/ar\/power-transformer-srkwdc\/#more-912\" aria-label=\"Read more about Power Transformer SRKWDC\">\u0625\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f<\/a><\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":{"0":"post-912","1":"page","2":"type-page","3":"status-publish","5":"no-featured-image-padding"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Power Transformer SRKWDC - Tengyi Electric<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tengyielectric.com\/ar\/\u0645\u062d\u0648\u0644-\u0627\u0644\u0637\u0627\u0642\u0629-srkwwdc\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Power Transformer SRKWDC - Tengyi Electric\" \/>\n<meta property=\"og:description\" content=\"Power Transformer Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services. Tengyi Power Transformer Advantages Tengyi main power transformer provides efficient voltage transformation, ensuring ... \u0625\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tengyielectric.com\/ar\/\u0645\u062d\u0648\u0644-\u0627\u0644\u0637\u0627\u0642\u0629-srkwwdc\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyi Electric\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-09T10:25:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u062f\u0642\u064a\u0642\u0629\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/\",\"name\":\"Power Transformer SRKWDC - Tengyi Electric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.jpg\",\"datePublished\":\"2025-01-17T06:19:35+00:00\",\"dateModified\":\"2025-07-09T10:25:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.jpg\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/110kv-power-transformer-design.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/power-transformer-srkwdc\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tengyielectric.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Power Transformer SRKWDC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#website\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/\",\"name\":\"Tengyi Electric\",\"description\":\"Leading Manufacturer on Transformer\",\"publisher\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tengyielectric.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#organization\",\"name\":\"Tengyi Electric\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.jpg\",\"contentUrl\":\"https:\\\/\\\/tengyielectric.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.jpg\",\"width\":1800,\"height\":570,\"caption\":\"Tengyi Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/tengyielectric.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 SRKWDC - Tengyi Electric - Tengyi Electric","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tengyielectric.com\/ar\/\u0645\u062d\u0648\u0644-\u0627\u0644\u0637\u0627\u0642\u0629-srkwwdc\/","og_locale":"ar_AR","og_type":"article","og_title":"Power Transformer SRKWDC - Tengyi Electric","og_description":"Power Transformer Offer custom-designed products with varying voltage levels to meet the requirements of different national power grids and provide OEM services. Tengyi Power Transformer Advantages Tengyi main power transformer provides efficient voltage transformation, ensuring ... \u0625\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f","og_url":"https:\/\/tengyielectric.com\/ar\/\u0645\u062d\u0648\u0644-\u0627\u0644\u0637\u0627\u0642\u0629-srkwwdc\/","og_site_name":"Tengyi Electric","article_modified_time":"2025-07-09T10:25:39+00:00","og_image":[{"url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"12 \u062f\u0642\u064a\u0642\u0629"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/","url":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/","name":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 SRKWDC - Tengyi Electric - Tengyi Electric","isPartOf":{"@id":"https:\/\/tengyielectric.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/#primaryimage"},"image":{"@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/#primaryimage"},"thumbnailUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg","datePublished":"2025-01-17T06:19:35+00:00","dateModified":"2025-07-09T10:25:39+00:00","breadcrumb":{"@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tengyielectric.com\/power-transformer-srkwdc\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/#primaryimage","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2025\/01\/110kv-power-transformer-design.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/tengyielectric.com\/power-transformer-srkwdc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tengyielectric.com\/"},{"@type":"ListItem","position":2,"name":"Power Transformer SRKWDC"}]},{"@type":"WebSite","@id":"https:\/\/tengyielectric.com\/#website","url":"https:\/\/tengyielectric.com\/","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","description":"\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0631\u0627\u0626\u062f\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a","publisher":{"@id":"https:\/\/tengyielectric.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tengyielectric.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/tengyielectric.com\/#organization","name":"\u062a\u0646\u063a\u064a\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643","url":"https:\/\/tengyielectric.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/tengyielectric.com\/#\/schema\/logo\/image\/","url":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.jpg","contentUrl":"https:\/\/tengyielectric.com\/wp-content\/uploads\/2024\/12\/logo.jpg","width":1800,"height":570,"caption":"Tengyi Electric"},"image":{"@id":"https:\/\/tengyielectric.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/pages\/912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/comments?post=912"}],"version-history":[{"count":0,"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/pages\/912\/revisions"}],"wp:attachment":[{"href":"https:\/\/tengyielectric.com\/ar\/wp-json\/wp\/v2\/media?parent=912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}